Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BY 4.0Scientific Reports

Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beams

Abstract

Concrete-filled steel tubular (CFST) columns are widely used in high-rise and long-span structures due to their high strength, stiffness, and ductility. However, conventional CFST column–reinforced concrete (RC) beam connections usually involve complex detailing, column capacity reduction, and inefficient construction. This study proposes a novel externally stiffened ring connection to overcome these drawbacks. A total of eight 1:5 scaled specimens were tested under low-cycle reversed loading, including welded and lapped configurations. The effects of axial compression ratio (0.33 , 0.50) and corbel length (120 mm , 240 mm) were systematically investigated. Nonlinear finite element (FE) models using ABAQUS were established to validate test results and reveal force-transfer mechanisms. Results indicate that all specimens achieved ductility coefficients greater than 5, satisfying seismic design requirements. Welded connections exhibited full spindle-shaped hysteretic loops, stable stiffness degradation, and superior energy dissipation, owing to continuous force transmission through welding. Lapped connections with short corbels experienced premature concrete splitting and low material efficiency, while those with long corbels showed improved ductility but lower economic efficiency. The FE models adopting the concrete damaged plasticity model and layered simulation accurately reproduced failure modes and backbone curves, with errors within 10%. This study confirms the effectiveness of the externally stiffened ring system. Welded connections are recommended for practical CFST frames, providing balanced seismic performance, constructability, and design simplicity.

Related

  1. Crushing Performance and Crack Development in Polymer-Fiber-Reinforced Precast Concrete Manhole Rings
    Materials (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  2. Mechanical performance of steel, basalt and polyamide fiber-reinforced ultra-high-performance concrete evaluated by experiments and SHAP-based machine learning
    Senem Yılmaz Çetin, Mete Burak Köse, Murat Doğruyol +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
  3. Surrogate assisted robust optimization balances mechanical performance and workability in fiber reinforced self compacting concrete
    Erfan Shirvani, Mohammadreza Habibi, Mohammad Hadi Tavana +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
  4. Fibre-Reinforced Concrete at Elevated Temperatures: Damage Mechanisms, Spalling, and Residual Performance
    Jinbo Xie, Wenlong Zhao, Xi Du +3
    Materials (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  5. Effect of recycled agricultural and industrial by-products on mechanical and durability properties of ultra high-performance fiber reinforced concrete
    Nada Mohamed Reda, Mohamed Abou Elmaaty, Mahmoud Elsayed
    Scientific ReportsPeer-reviewedCC BY 4.0Full textCrossref
BibTeX
@article{zha2026seismic,
  title = {{Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beams}},
  author = {Bo Zha and Shichun Zhang},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-75173-0},
  url = {https://www.nature.com/articles/s41598-026-75173-0},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beams
AU  - Bo Zha
AU  - Shichun Zhang
PY  - 2026
DA  - 2026/10/11
JO  - Scientific Reports
DO  - 10.1038/s41598-026-75173-0
UR  - https://www.nature.com/articles/s41598-026-75173-0
AB  - Concrete-filled steel tubular (CFST) columns are widely used in high-rise and long-span structures due to their high strength, stiffness, and ductility. However, conventional CFST column–reinforced concrete (RC) beam connections usually involve complex detailing, column capacity reduction, and inefficient construction. This study proposes a novel externally stiffened ring connection to overcome these drawbacks. A total of eight 1:5 scaled specimens were tested under low-cycle reversed loading, including welded and lapped configurations. The effects of axial compression ratio (0.33 , 0.50) and corbel length (120 mm , 240 mm) were systematically investigated. Nonlinear finite element (FE) models using ABAQUS were established to validate test results and reveal force-transfer mechanisms. Results indicate that all specimens achieved ductility coefficients greater than 5, satisfying seismic design requirements. Welded connections exhibited full spindle-shaped hysteretic loops, stable stiffness degradation, and superior energy dissipation, owing to continuous force transmission through welding. Lapped connections with short corbels experienced premature concrete splitting and low material efficiency, while those with long corbels showed improved ductility but lower economic efficiency. The FE models adopting the concrete damaged plasticity model and layered simulation accurately reproduced failure modes and backbone curves, with errors within 10%. This study confirms the effectiveness of the externally stiffened ring system. Welded connections are recommended for practical CFST frames, providing balanced seismic performance, constructability, and design simplicity.
SN  - 2045-2322
ER  -