Skip to content
DraconiticResearch
Search Sources API
197,785 studies31 sourcesUpdated 38 min ago
PreprintarXiv licencearXiv

Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA

Abstract

This work details some of the recent radiological studies performed at National Synchrotron Light Source II (NSLS-II) using the Monte Carlo (MC) particle transport code FLUKA. In particular, it assesses the radiation protection challenges posed by the anticipated NSLS-II facility upgrade, taking into consideration various upgrade options. Also, it evaluates the impact related to the use of different shielding materials and the employment of ambient dose H* as the external radiation exposure estimator of effective dose. Lastly, a demonstration of synchrotron radiation transport is provided for an in-silico beamline, all the way from the radiation source to end-station, utilizing FLUKA's recent X-ray reflectivity capabilities.

Related

  1. Uncertainty in AI driven Monte Carlo simulations
    Dimitrios Tzivrailis, Alberto Rosso, Eiji Kawasaki
    Physical Review EPeer-reviewedHAL deposit licenceFull textStatisticsCondensed matterHAL
  2. Unbiased Diffusion Monte Carlo for non local operators
    Carlos Rodriguez Perez, Valerio Olevano, Francesco Sottile +1
    HALPreprintLicence not statedGeneral physicsHAL
  3. A control variates technique for the null-collision Monte Carlo algorithms in radiative transfer
    Zili He, Anthony Arfaux, Yaniss Nyffenegger-Péré +1
    Journal of Quantitative Spectroscopy and Radiative TransferPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  4. Design and Monte Carlo simulation of a phase grating moiré neutron interferometer to measure the gravitational constant
    C. Kapahi, D. Sarenac, B. Heacock +5
    Communications PhysicsPeer-reviewedCC BY-NC-ND 4.0Atomic, molecular & optical physicsCrossref
  5. Magnetic structures in a model nickelate: Monte Carlo study
    V. S. Ryumshin, Yu. D. Panov, A. S. Moskvin
    arXivPreprintCC BY 4.0Full textStatistical & nonlinear physicsarXiv
BibTeX
@misc{augusto2026recent,
  title = {{Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA}},
  author = {Ricardo dos Santos Augusto and Robert J. Lee},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.00611},
  eprint = {2610.00611},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.00611},
}
RIS
TY  - UNPB
TI  - Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA
AU  - Ricardo dos Santos Augusto
AU  - Robert J. Lee
PY  - 2026
DA  - 2026/10/01
PB  - arXiv
DO  - 10.48550/arxiv.2610.00611
UR  - https://arxiv.org/abs/2610.00611
AB  - This work details some of the recent radiological studies performed at National Synchrotron Light Source II (NSLS-II) using the Monte Carlo (MC) particle transport code FLUKA. In particular, it assesses the radiation protection challenges posed by the anticipated NSLS-II facility upgrade, taking into consideration various upgrade options. Also, it evaluates the impact related to the use of different shielding materials and the employment of ambient dose H* as the external radiation exposure estimator of effective dose. Lastly, a demonstration of synchrotron radiation transport is provided for an in-silico beamline, all the way from the radiation source to end-station, utilizing FLUKA's recent X-ray reflectivity capabilities.
ER  -