PreprintarXiv licencearXiv
Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA
Abstract
This work details some of the recent radiological studies performed at National Synchrotron Light Source II (NSLS-II) using the Monte Carlo (MC) particle transport code FLUKA. In particular, it assesses the radiation protection challenges posed by the anticipated NSLS-II facility upgrade, taking into consideration various upgrade options. Also, it evaluates the impact related to the use of different shielding materials and the employment of ambient dose H* as the external radiation exposure estimator of effective dose. Lastly, a demonstration of synchrotron radiation transport is provided for an in-silico beamline, all the way from the radiation source to end-station, utilizing FLUKA's recent X-ray reflectivity capabilities.
Related
- Uncertainty in AI driven Monte Carlo simulations
- Unbiased Diffusion Monte Carlo for non local operators
- A control variates technique for the null-collision Monte Carlo algorithms in radiative transfer
- Design and Monte Carlo simulation of a phase grating moiré neutron interferometer to measure the gravitational constant
- Magnetic structures in a model nickelate: Monte Carlo study
BibTeX
@misc{augusto2026recent,
title = {{Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA}},
author = {Ricardo dos Santos Augusto and Robert J. Lee},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.00611},
eprint = {2610.00611},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.00611},
}
RIS
TY - UNPB
TI - Recent radiological studies at NSLS-II using the Monte Carlo code FLUKA
AU - Ricardo dos Santos Augusto
AU - Robert J. Lee
PY - 2026
DA - 2026/10/01
PB - arXiv
DO - 10.48550/arxiv.2610.00611
UR - https://arxiv.org/abs/2610.00611
AB - This work details some of the recent radiological studies performed at National Synchrotron Light Source II (NSLS-II) using the Monte Carlo (MC) particle transport code FLUKA. In particular, it assesses the radiation protection challenges posed by the anticipated NSLS-II facility upgrade, taking into consideration various upgrade options. Also, it evaluates the impact related to the use of different shielding materials and the employment of ambient dose H* as the external radiation exposure estimator of effective dose. Lastly, a demonstration of synchrotron radiation transport is provided for an in-silico beamline, all the way from the radiation source to end-station, utilizing FLUKA's recent X-ray reflectivity capabilities.
ER -