Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 34 min ago
Peer-reviewedCC BY 4.0Advanced Pharmaceutical Bulletin

Development of a Flow Cytometric Immunoassay Using Recombinant Vascular Endothelial Growth Factor (VEGF)-Functionalized Poly(ε-Caprolactone) Microbeads for Bevacizumab Quantification

  1. 1Biomaterial Group, Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
  2. 2Biotechnology Research Center, Pasteur Institute of Iran, Tehran, Iran
  3. 3Department of Molecular and Cellular Sciences, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran

Abstract

Purpose:: With the growing research interest in therapeutic monoclonal antibodies (mAbs) and their broad range of applications, the development of reliable analytical approaches for their quantification has become increasingly important. Since, microbead (MB)-based flow cytometric immunoassays have emerged as highly sensitive analytical methods, the aim of this study was to develop and evaluate a flow cytometry-based method using poly(ε-caprolactone) (PCL) MBs to quantify bevacizumab (BVZ) concentration.

Methods:: PCL MBs were synthesized through the emulsion/solvent evaporation method and modified by reaction with 1,2-ethylenediamine (EDA) to enable covalent binding of biomolecules. Based on the optimal biomolecule immobilization conditions determined using a model protein, purified recombinant vascular endothelial growth factor (VEGF) protein was immobilized on the surface of amine-functionalized MBs (A-MBs(45)) to capture BVZ, which was then detected using fluorescein isothiocyanate (FITC)-conjugated anti-human IgG antibody in flow cytometry.

Results:: The synthesized PCL MBs, with an average diameter of 6.62±0.17 µm, were within the suitable particle size range for immunoassay applications. The optimal aminolysis time was found to be 45 min at 37 °C, and the maximum protein coupling was achieved 5 h post-incubation at pH 8.0. The developed MB-based flow cytometric immunoassay demonstrated the potential to quantify BVZ with a limit of detection (LOD) and limit of quantification (LOQ) of about 6.71 and 22.73 ng mL-1, respectively.

Conclusion:: Considering the ease of fabrication and functionalization of PCL MBs under the obtained optimal conditions, along with their capability for analyte detection, these cost-effective analytical platforms may serve as promising candidates for BVZ quantification.

Related

  1. Establishment of Reverse Transcription Polymerase Chain Reaction Method for Quantification of Residual Host Cell RNA in Recombinant Plasmid Drugs
    Hua Bi, Bo Zhang, Xinchang Shi +8
    MoleculesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationCrossrefEurope PMC
  2. Chimeric Virus-like Particles of Bacteriophage Beihai32, Displaying the M2e Peptide and Conserved Antigens from the Hemagglutinin and Neuraminidase of the Influenza A Virus as a Platform for Recombinant Vaccine Development
    Anna A. Zykova, Eugenia S. Mardanova, Marina A. Shuklina +4
    BiomoleculesPeer-reviewedCC BY 4.0Full textGeneral biochemistryCrossrefEurope PMC
  3. Development of an effective direct qPCR method for cell therapy product quantification in non-clinical biodistribution studies.
    Yoichi Naritomi, Yuka Sato, Kumiko Goto +3
    Regenerative therapyPeer-reviewedCC BY-NC-NDFull textMolecular biology & gene regulationEurope PMC
  4. Detection method for carrying Hepatitis B surface antigen exosomes by a chemiluminescence immunoassay (CLIA)
    Yihui Rong, Wende Li, Lijuan Wang +1
    BioanalysisPeer-reviewedLicence not statedFull textMolecular biology & gene regulationPMC
  5. Electrospun Poly(lactide-co-glycolide-co-ε-caprolactone) as a Bioresorbable Platform for Docetaxel-Degradation, Drug Delivery Study and Anticancer Activity
    Joanna Jaworska, Arkadiusz Orchel, Anna Kaps +6
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0General biochemistryCrossref
BibTeX
@article{namaeighasemnia2026development,
  title = {{Development of a Flow Cytometric Immunoassay Using Recombinant Vascular Endothelial Growth Factor (VEGF)-Functionalized Poly(ε-Caprolactone) Microbeads for Bevacizumab Quantification}},
  author = {Negar Namaei-Ghasemnia and Mohammad Rabiee and Fatemeh Davami and Yeganeh Talebkhan-Garoosi and Mohamad Ghorbani},
  journal = {Advanced Pharmaceutical Bulletin},
  year = {2026},
  month = jul,
  doi = {10.34172/apb.46777},
  url = {https://doi.org/10.34172/apb.46777},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Development of a Flow Cytometric Immunoassay Using Recombinant Vascular Endothelial Growth Factor (VEGF)-Functionalized Poly(ε-Caprolactone) Microbeads for Bevacizumab Quantification
AU  - Negar Namaei-Ghasemnia
AU  - Mohammad Rabiee
AU  - Fatemeh Davami
AU  - Yeganeh Talebkhan-Garoosi
AU  - Mohamad Ghorbani
PY  - 2026
DA  - 2026/07/11
JO  - Advanced Pharmaceutical Bulletin
DO  - 10.34172/apb.46777
UR  - https://doi.org/10.34172/apb.46777
AB  - Purpose:: With the growing research interest in therapeutic monoclonal antibodies (mAbs) and their broad range of applications, the development of reliable analytical approaches for their quantification has become increasingly important. Since, microbead (MB)-based flow cytometric immunoassays have emerged as highly sensitive analytical methods, the aim of this study was to develop and evaluate a flow cytometry-based method using poly(ε-caprolactone) (PCL) MBs to quantify bevacizumab (BVZ) concentration.  Methods:: PCL MBs were synthesized through the emulsion/solvent evaporation method and modified by reaction with 1,2-ethylenediamine (EDA) to enable covalent binding of biomolecules. Based on the optimal biomolecule immobilization conditions determined using a model protein, purified recombinant vascular endothelial growth factor (VEGF) protein was immobilized on the surface of amine-functionalized MBs (A-MBs(45)) to capture BVZ, which was then detected using fluorescein isothiocyanate (FITC)-conjugated anti-human IgG antibody in flow cytometry.  Results:: The synthesized PCL MBs, with an average diameter of 6.62±0.17 µm, were within the suitable particle size range for immunoassay applications. The optimal aminolysis time was found to be 45 min at 37 °C, and the maximum protein coupling was achieved 5 h post-incubation at pH 8.0. The developed MB-based flow cytometric immunoassay demonstrated the potential to quantify BVZ with a limit of detection (LOD) and limit of quantification (LOQ) of about 6.71 and 22.73 ng mL-1, respectively.  Conclusion:: Considering the ease of fabrication and functionalization of PCL MBs under the obtained optimal conditions, along with their capability for analyte detection, these cost-effective analytical platforms may serve as promising candidates for BVZ quantification.
SN  - 2228-5881
SN  - 2251-7308
ER  -