Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY 4.0Diagnostics

Does the Quantum Layer Help? A Leakage-Aware Benchmark of Hybrid Quantum–Classical Models for Brain Tumor MRI Classification

7 affiliations
  1. 1The Laboratory Center, Hanoi University of Public Health, Hanoi 100000, Vietnam
  2. 2Department of Physics, Faculty of Mathematics and Natural Sciences, IPB University, Bogor 16680, Indonesia; (P.W.M.); (T.S.); (S.Y.)
  3. 3Department of Medical Physics, Faculty of Medicine, Nguyen Tat Thanh University, 298-300A Nguyen Tat Thanh Street, Ho Chi Minh City 700000, Vietnam
  4. 4Department of Radiological Sciences, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 34212, Saudi Arabia
  5. 5Department of Physics, College of Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
  6. 6Department of Radiological Sciences, College of Applied Medical Sciences, King Saud bin Abdulaziz University for Health Sciences, P.O. Box 6664, Al Ahsa 31982, Saudi Arabia
  7. 7Imaging Physics Section, Research and Innovation Department, King Faisal Specialist Hospital & Research Center, P.O. Box 3354, Riyadh 11211, Saudi Arabia

Abstract

Background/Objectives: Hybrid quantum–classical neural networks are reported to classify brain tumors on magnetic resonance imaging (MRI) accurately, but these reports rarely control for data leakage or test whether the quantum circuit contributes. We examined both issues. Methods: We audited version 2 of the Kaggle Brain Tumor MRI Dataset (7200 images) with mirror- and rotation-invariant duplicate detection and by matching every image to its source collections, which recovered patient identities for 4846 tumor images. A variational quantum circuit (VQC) was compared with size-matched, deeper and Fourier-surrogate classical controls using frozen features, end-to-end fine-tuning and training from scratch, all under patient-grouped five-fold cross-validation. Results: Of the 1600 test images, 1269 (79%) had a copy in the training partition, and 915 of the 917 figshare-derived test images shared a patient with it. On frozen features, a six-qubit VQC head was 6.0 percentage points (pp) less accurate than its classical control (95% confidence interval −6.8 to −5.2) and less accurate than a classical surrogate of its own function class. With fine-tuning, it stayed within about 1 pp of its control but was 0.7 pp less accurate (−1.2 to −0.1) after convergence-based training; a hybrid network trained from scratch was 8.3 pp less accurate than its control. Patient-grouped evaluation lowered accuracy by 3–8 pp relative to our earlier duplicate-grouped evaluation, and 76 glioma test images from another source remained poorly recognized. Conclusions: The quantum layer added cost but no accuracy, and leakage and provenance mattered more than the classifier head.

Related

  1. Exposing Patient-Level Data Leakage in Respiratory Sound Classification: A Leakage-Free Benchmark Leveraging Transformer-Based TabPFN-3 and Knowledge Distillation
    Okan Düzyel, Mehmet Kuntalp, Fevzi Yasin Kababulut +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. LQ-HybridNet: A Parameter-Compact Classical Architecture with Quantum-Inspired Feature Transformations for Skin Lesion Classification
    Prateek Singh, Sudhakar Singh, Manoj Kumar Jena +3
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. A Reproducible Benchmark for Leakage-Resistant Machine Learning on Multi-Site Brain Connectivity Graphs
    Abu Ubaida, Khurram Zeeshan Haider, Salabat Khan +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. A hybrid quantum algorithm for multi-resolution arrhythmia classification
    Melvin Yashnil Ramkhelawan, Santoso Wibowo, Srimannarayana Grandhi +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicineCrossref
  5. Comparative Analysis of Classical, Fractional, and Quantum Calculus Models for Measles Transmission Dynamics
    Mahmoud H. DarAssi, Bashir Al-Hdaibat, Yousef AbuHour +2
    Fractal and FractionalPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
BibTeX
@article{duong2026does,
  title = {{Does the Quantum Layer Help? A Leakage-Aware Benchmark of Hybrid Quantum–Classical Models for Brain Tumor MRI Classification}},
  author = {Tuan-Linh Duong and Pande Wikantyasa Maswita and Tony Sumaryada and Sitti Yani and Thanh-Tai Duong and Hiba Omer and Nissren Tamam and Abdelmoneim Sulieman},
  journal = {Diagnostics},
  year = {2026},
  month = oct,
  doi = {10.3390/diagnostics16213485},
  url = {https://doi.org/10.3390/diagnostics16213485},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Does the Quantum Layer Help? A Leakage-Aware Benchmark of Hybrid Quantum–Classical Models for Brain Tumor MRI Classification
AU  - Tuan-Linh Duong
AU  - Pande Wikantyasa Maswita
AU  - Tony Sumaryada
AU  - Sitti Yani
AU  - Thanh-Tai Duong
AU  - Hiba Omer
AU  - Nissren Tamam
AU  - Abdelmoneim Sulieman
PY  - 2026
DA  - 2026/10/24
JO  - Diagnostics
DO  - 10.3390/diagnostics16213485
UR  - https://doi.org/10.3390/diagnostics16213485
AB  - Background/Objectives: Hybrid quantum–classical neural networks are reported to classify brain tumors on magnetic resonance imaging (MRI) accurately, but these reports rarely control for data leakage or test whether the quantum circuit contributes. We examined both issues. Methods: We audited version 2 of the Kaggle Brain Tumor MRI Dataset (7200 images) with mirror- and rotation-invariant duplicate detection and by matching every image to its source collections, which recovered patient identities for 4846 tumor images. A variational quantum circuit (VQC) was compared with size-matched, deeper and Fourier-surrogate classical controls using frozen features, end-to-end fine-tuning and training from scratch, all under patient-grouped five-fold cross-validation. Results: Of the 1600 test images, 1269 (79%) had a copy in the training partition, and 915 of the 917 figshare-derived test images shared a patient with it. On frozen features, a six-qubit VQC head was 6.0 percentage points (pp) less accurate than its classical control (95% confidence interval −6.8 to −5.2) and less accurate than a classical surrogate of its own function class. With fine-tuning, it stayed within about 1 pp of its control but was 0.7 pp less accurate (−1.2 to −0.1) after convergence-based training; a hybrid network trained from scratch was 8.3 pp less accurate than its control. Patient-grouped evaluation lowered accuracy by 3–8 pp relative to our earlier duplicate-grouped evaluation, and 76 glioma test images from another source remained poorly recognized. Conclusions: The quantum layer added cost but no accuracy, and leakage and provenance mattered more than the classifier head.
SN  - 2075-4418
ER  -