Terahertz sensor with parity time symmetry for enhanced detection of frozen oral cancer tissues
Abstract
In this work, we present a defect-engineered one-dimensional photonic crystal (1D-PhC) operating in the terahertz regime, designed on the principle of parity-time (PT) symmetry for highly sensitive detection of frozen oral cancer cells. The proposed sensor is a one-dimensional parity–time-symmetric photonic crystal consisting of repeated silicon dioxide/porous silicon bilayers surrounding a central defect layer on a substrate, where the defect layer serves as the sensing region for frozen oral tissues. The transfer matrix method is employed to investigate the shift in the defect mode characteristics in the transmittance spectrum. By incorporating a complex refractive index distribution that fulfills PT-symmetric conditions, the system acquires non-Hermitian characteristics, resulting in sharp resonances and tunable defect mode responses. The simulation results reveal that the introduction of PT-symmetric gain and loss (Q) layers remarkably enhances the sensitivity compared to conventional PhC-based sensors. The proposed design achieves transmittance-based sensitivity of 2.4× 1011 %/RIU and 1.7× 1010 %/RIU , whereas spectra-based sensitivity of 68.8 GHz/RIU and 68.8 GHz/RIU for Q = 10.695 and 7.85, respectively. Along with its high sensitivity, the simplicity and fabrication feasibility of the structure make it a promising platform for real-time, label-free early-stage oral cancer detection.
Related
- WTe2 Weyl semimetal conical microarray enabled quantum-enhanced terahertz photocurrent sensing for organophosphorus toxin detection in simulated body fluid
- The macrophage as a neuroimmune sensor and effector: neural control of inflammation across tissues and disease
- Optimization-enhanced machine failure classification using critical sensor features and hybrid learning models with advanced optimization techniques
- Associations of uric acid with wearable sensor-derived digital gait characteristics in older adults: vigor, symmetry, and stability
- Hybrid quantum-classical machine learning for industrial multi-anomaly detection via single acoustic sensor
BibTeX
@article{zaky2026terahertz,
title = {{Terahertz sensor with parity time symmetry for enhanced detection of frozen oral cancer tissues}},
author = {Zaky A. Zaky and Ali Hennache and Abinash Panda},
journal = {Scientific Reports},
year = {2026},
month = oct,
doi = {10.1038/s41598-026-73529-0},
url = {https://www.nature.com/articles/s41598-026-73529-0},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Terahertz sensor with parity time symmetry for enhanced detection of frozen oral cancer tissues
AU - Zaky A. Zaky
AU - Ali Hennache
AU - Abinash Panda
PY - 2026
DA - 2026/10/01
JO - Scientific Reports
DO - 10.1038/s41598-026-73529-0
UR - https://www.nature.com/articles/s41598-026-73529-0
AB - In this work, we present a defect-engineered one-dimensional photonic crystal (1D-PhC) operating in the terahertz regime, designed on the principle of parity-time (PT) symmetry for highly sensitive detection of frozen oral cancer cells. The proposed sensor is a one-dimensional parity–time-symmetric photonic crystal consisting of repeated silicon dioxide/porous silicon bilayers surrounding a central defect layer on a substrate, where the defect layer serves as the sensing region for frozen oral tissues. The transfer matrix method is employed to investigate the shift in the defect mode characteristics in the transmittance spectrum. By incorporating a complex refractive index distribution that fulfills PT-symmetric conditions, the system acquires non-Hermitian characteristics, resulting in sharp resonances and tunable defect mode responses. The simulation results reveal that the introduction of PT-symmetric gain and loss (Q) layers remarkably enhances the sensitivity compared to conventional PhC-based sensors. The proposed design achieves transmittance-based sensitivity of 2.4× 10^11 %/RIU and 1.7× 10^10 %/RIU , whereas spectra-based sensitivity of 68.8 GHz/RIU and 68.8 GHz/RIU for Q = 10.695 and 7.85, respectively. Along with its high sensitivity, the simplicity and fabrication feasibility of the structure make it a promising platform for real-time, label-free early-stage oral cancer detection.
SN - 2045-2322
ER -