Multicenter Evaluation of Decentralized Homologous Recombination Deficiency Testing for Enhanced Molecular Diagnosis of Ovarian Cancer
7 affiliations
- 1Pathology Department, Hospital del Mar Research Institute, Barcelona 08003, Spain
- 2Centro de Investigación Biomédica en Red de Cáncer (CIBERONC), ISCIII, Madrid 08028, Spain
- 3Pathology Department, Hospital Universitari Vall d’Hebron, Barcelona 08035, Spain
- 4Translational Molecular Pathology, Vall d’Hebron Institut de Recerca, Barcelona 08035, Spain
- 5Molecular Biology CORE, Hospital Clínic de Barcelona, Barcelona 08036, Spain
- 6Pathology Department, Hospital Clínic de Barcelona, Barcelona 08036, Spain
- 7August Pi i Sunyer Biomedical Research Institute (IDIBAPS), University of Barcelona, Barcelona 08036, Spain
Abstract
Assessment of homologous recombination deficiency (HRD) and tumor BRCA1/2 mutation status in high-grade serous ovarian carcinoma (HGSOC) is clinically relevant for treatment decisions and for identifying tumors that may benefit from poly(adenosine diphosphate–ribose) polymerase inhibitors. The Myriad MyChoice® CDx HRD (M-HRD) assay is an established clinically validated HRD testing platform that is performed as a send-out test. We conducted a multicenter pilot study to assess the analytical feasibility and interlaboratory agreement of decentralized testing using the SOPHiA DDM™ Dx HRD Solution (SG-HRD). Three hospitals each contributed eight clinical HGSOC samples previously tested with M-HRD or with SG-HRD in a send-out platform. All centers independently prepared SG-HRD libraries and sequenced the complete set of 24 samples. Agreement with M-HRD was evaluated separately from comparisons with previous SG-HRD send-out results. Among specimens with interpretable M-HRD, overall percent agreement with local SG-HRD results was 95.0% (19/20), 90.0% (18/20), and 88.9% (16/18) at the three hospitals. BRCA1/2 variant calls were concordant with previous testing. Overall, the comparison with previous analyses by Myriad genetics or with previous SOPHiA GENETICS send-out results showed a high level of agreement, with discordances mainly observed in samples with values close to the classification threshold. The small, selected cohort, limited clinical replication, and absence of treatment-outcome assessment restrict precision estimates, generalizability, and conclusions regarding clinical validity. These findings support the analytical feasibility of decentralized SG-HRD testing, but larger studies are needed to characterize performance across a broader range of specimens and testing conditions.
Related
- m7G modification in mRNA cooperates with QKI to promote homologous recombination repair
- Structures and molecular mechanisms of RAD54B in modulating homologous recombination
- SNORD18B/SNORD18C-RPL23A promotes homologous recombination repair by regulating BRCA1 translation in colorectal cancer cells
- DTX3 Suppresses the NPM3-RUVBL1 Axis to Inhibit Homologous Recombination Repair and Abrogate Tumor Radioresistance.
- Navigating nuclear space: How Rad51 filaments promote long-range homology search during homologous recombination – Lessons from budding yeast
BibTeX
@article{vargasparra2026multicenter,
title = {{Multicenter Evaluation of Decentralized Homologous Recombination Deficiency Testing for Enhanced Molecular Diagnosis of Ovarian Cancer}},
author = {Gardenia Vargas-Parra and Marta Sesé and Eva Hernández-Illán and Laia Serrano and Laura Camacho and Rosa Somoza and Vanessa López and Cristina Teixido and Pedro Jares and Javier Hernández-Losa and Beatriz Bellosillo},
journal = {International Journal of Molecular Sciences},
year = {2026},
month = nov,
doi = {10.3390/ijms272110028},
url = {https://www.mdpi.com/1422-0067/27/21/10028},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Multicenter Evaluation of Decentralized Homologous Recombination Deficiency Testing for Enhanced Molecular Diagnosis of Ovarian Cancer
AU - Gardenia Vargas-Parra
AU - Marta Sesé
AU - Eva Hernández-Illán
AU - Laia Serrano
AU - Laura Camacho
AU - Rosa Somoza
AU - Vanessa López
AU - Cristina Teixido
AU - Pedro Jares
AU - Javier Hernández-Losa
AU - Beatriz Bellosillo
PY - 2026
DA - 2026/11/09
JO - International Journal of Molecular Sciences
DO - 10.3390/ijms272110028
UR - https://www.mdpi.com/1422-0067/27/21/10028
AB - Assessment of homologous recombination deficiency (HRD) and tumor BRCA1/2 mutation status in high-grade serous ovarian carcinoma (HGSOC) is clinically relevant for treatment decisions and for identifying tumors that may benefit from poly(adenosine diphosphate–ribose) polymerase inhibitors. The Myriad MyChoice® CDx HRD (M-HRD) assay is an established clinically validated HRD testing platform that is performed as a send-out test. We conducted a multicenter pilot study to assess the analytical feasibility and interlaboratory agreement of decentralized testing using the SOPHiA DDM™ Dx HRD Solution (SG-HRD). Three hospitals each contributed eight clinical HGSOC samples previously tested with M-HRD or with SG-HRD in a send-out platform. All centers independently prepared SG-HRD libraries and sequenced the complete set of 24 samples. Agreement with M-HRD was evaluated separately from comparisons with previous SG-HRD send-out results. Among specimens with interpretable M-HRD, overall percent agreement with local SG-HRD results was 95.0% (19/20), 90.0% (18/20), and 88.9% (16/18) at the three hospitals. BRCA1/2 variant calls were concordant with previous testing. Overall, the comparison with previous analyses by Myriad genetics or with previous SOPHiA GENETICS send-out results showed a high level of agreement, with discordances mainly observed in samples with values close to the classification threshold. The small, selected cohort, limited clinical replication, and absence of treatment-outcome assessment restrict precision estimates, generalizability, and conclusions regarding clinical validity. These findings support the analytical feasibility of decentralized SG-HRD testing, but larger studies are needed to characterize performance across a broader range of specimens and testing conditions.
SN - 1422-0067
ER -