Inflammation-associated clinical prognostic factors and primary patency after drug-coated balloon angioplasty for recurrent autogenous arteriovenous fistula stenosis: a single-center retrospective cohort study.
5 affiliations
- 1Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China.
- 2Department of Nephrology, The Affiliated Cancer Hospital of Guizhou Medical University, Guiyang, Guizhou, China.
- 3Department of Nephrology, Xining Second People's Hospital, Xining, Qinghai, China.
- 4Department of Nephrology, Beijing Haidian Hospital (Haidian Section of Peking University Third Hospital), Beijing, China.
- 5Qihuang College, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China.
Abstract
Background
Recurrent autogenous arteriovenous fistula (AVF) stenosis occurs in a vascular environment in which injury, neointimal hyperplasia and inflammation may coexist. Whether routine inflammatory or hematological markers contribute to clinical prognosis after drug-coated balloon (DCB) angioplasty remains uncertain. This retrospective study examines clinical outcomes and inflammation-related prognostic associations without assuming that inflammatory pathways were measured or causally established.Methods
This single-center retrospective cohort comprised 357 patients treated between February 2023 and May 2026. The primary outcome was time from index DCB angioplasty to clinically driven target-lesion reintervention. Kaplan-Meier and Cox analyses used available follow-up; a separate clinical logistic model addressed failure within 12 months in 356 patients with complete model data. No non-DCB comparator or patient-level molecular measurements were available.Results
Mean brachial-artery flow increased from 288.98 ± 139.37 to 980.92 ± 174.66 mL/min and minimal luminal diameter from 1.52 ± 0.50 to 5.21 ± 0.63 mm (both P < 0.001). Kaplan-Meier primary patency was 95.24%, 84.03%, 68.90%, and 55.40% at 3, 6, 9, and 12 months. In the extended Cox model (338 patients; 191 events), previous PTA count (HR 1.129 per procedure, P = 0.003) and lesion length (HR 1.105 per cm, P = 0.001) were associated with greater hazard; postprocedural flow (HR 0.889 per 100 mL/min, P = 0.014) and red-blood-cell count (HR 0.804 per 10¹²/L, P = 0.027) were associated with lower hazard. The five-fold cross-validated AUC of the clinical 12-month model was 0.706.Conclusion
In this selected single-center cohort, recurrent AVF stenosis after DCB angioplasty was associated with previous PTA burden, lesion length, postprocedural flow, and red-blood-cell count. Routine blood-cell measures provide an exploratory inflammation-related clinical context but do not establish inflammatory mechanisms or validate a specific inflammatory biomarker. Independent validation and patient-level inflammatory measurements are required.
Related
- Ultrasound-guided angioplasty of arteriovenous fistula for hemodialysis: initial experience of a single center
- Ultrasound-First Rheolytic Thrombectomy for Thrombosed Native Arteriovenous Fistulas with Ultrasound-Guided Angioplasty and Longitudinal Surveillance
- Prognostic Value of the Pretreatment Global Immune–Nutrition–Inflammation Index in Nasopharyngeal Carcinoma: A Multicenter Retrospective Cohort Study
- Thrombus burden-stratified catheter-directed thrombolysis combined with percutaneous transluminal angioplasty for acute arteriovenous graft thrombosis in hemodialysis patients: a comparison of single-session versus extended infusion protocols
- Prognostic Value of the Pan-Immune-Inflammation Value and Delta Neutrophil Index for In-Hospital Mortality and Postoperative Adverse Events After Open Repair of Ruptured Abdominal Aortic Aneurysm: A Retrospective Single-Center Study
BibTeX
@article{su2026inflammationassociated,
title = {{Inflammation-associated clinical prognostic factors and primary patency after drug-coated balloon angioplasty for recurrent autogenous arteriovenous fistula stenosis: a single-center retrospective cohort study.}},
author = {Chaojiang Su and Chengwen Dang and Huan Wu and Yan Jiang and Yiping Yan and Lizhu Wang and Guanglei Chen and Liting Liu and Yan Chen and Zongyang Liu and Bin Zhao and Yunzhi Chen},
journal = {Frontiers in cell and developmental biology},
year = {2026},
month = oct,
doi = {10.3389/fcell.2026.1977789},
url = {https://europepmc.org/article/MED/43011035},
note = {CC BY},
}
RIS
TY - JOUR
TI - Inflammation-associated clinical prognostic factors and primary patency after drug-coated balloon angioplasty for recurrent autogenous arteriovenous fistula stenosis: a single-center retrospective cohort study.
AU - Chaojiang Su
AU - Chengwen Dang
AU - Huan Wu
AU - Yan Jiang
AU - Yiping Yan
AU - Lizhu Wang
AU - Guanglei Chen
AU - Liting Liu
AU - Yan Chen
AU - Zongyang Liu
AU - Bin Zhao
AU - Yunzhi Chen
PY - 2026
DA - 2026/10/27
JO - Frontiers in cell and developmental biology
DO - 10.3389/fcell.2026.1977789
UR - https://europepmc.org/article/MED/43011035
AB - Background Recurrent autogenous arteriovenous fistula (AVF) stenosis occurs in a vascular environment in which injury, neointimal hyperplasia and inflammation may coexist. Whether routine inflammatory or hematological markers contribute to clinical prognosis after drug-coated balloon (DCB) angioplasty remains uncertain. This retrospective study examines clinical outcomes and inflammation-related prognostic associations without assuming that inflammatory pathways were measured or causally established.Methods This single-center retrospective cohort comprised 357 patients treated between February 2023 and May 2026. The primary outcome was time from index DCB angioplasty to clinically driven target-lesion reintervention. Kaplan-Meier and Cox analyses used available follow-up; a separate clinical logistic model addressed failure within 12 months in 356 patients with complete model data. No non-DCB comparator or patient-level molecular measurements were available.Results Mean brachial-artery flow increased from 288.98 ± 139.37 to 980.92 ± 174.66 mL/min and minimal luminal diameter from 1.52 ± 0.50 to 5.21 ± 0.63 mm (both P < 0.001). Kaplan-Meier primary patency was 95.24%, 84.03%, 68.90%, and 55.40% at 3, 6, 9, and 12 months. In the extended Cox model (338 patients; 191 events), previous PTA count (HR 1.129 per procedure, P = 0.003) and lesion length (HR 1.105 per cm, P = 0.001) were associated with greater hazard; postprocedural flow (HR 0.889 per 100 mL/min, P = 0.014) and red-blood-cell count (HR 0.804 per 10¹²/L, P = 0.027) were associated with lower hazard. The five-fold cross-validated AUC of the clinical 12-month model was 0.706.Conclusion In this selected single-center cohort, recurrent AVF stenosis after DCB angioplasty was associated with previous PTA burden, lesion length, postprocedural flow, and red-blood-cell count. Routine blood-cell measures provide an exploratory inflammation-related clinical context but do not establish inflammatory mechanisms or validate a specific inflammatory biomarker. Independent validation and patient-level inflammatory measurements are required.
SN - 2296-634X
ER -