Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 6 min ago
PreprintarXiv licencearXiv

Critical quantum metrology in the output of an optical parametric oscillator

Abstract

Many quantum sensors infer parameters from continuously emitted fields, yet in the presence of unmonitored loss, it is difficult to determine how much critical enhancement survives in the accessible output. In this work, we calculate the full frequency-resolved output quantum Fisher information (QFI) of a stationary vacuum-seeded optical parametric oscillator for cavity-detuning estimation. We show that, for any fixed nonzero unmonitored loss, the QFI of correlated sideband pairs grows quadratically with the mean intracavity photon number near threshold, but only within a spectral window that narrows inversely with that number; consequently, the spectrum-integrated output QFI rate scales asymptotically only linearly. We identify a far-detuned, near-threshold regime in which the monitored output alone asymptotically approaches the loss-imposed upper bound on the joint cavity-output QFI. We further determine the operating points that maximize the output QFI rate per intracavity photon and introduce a frequency-resolved homodyne strategy that maximizes the Fisher information obtainable from a single record. Our results establish an operational connection between critical enhancement and metrological information accessible in the output field, while providing concrete guidance for the design and readout of dissipative parametric sensors.

Related

  1. Red picosecond fiber optical parametric oscillator pumped at 914 nm by an Nd-doped MOPA laser source
    Arnaud Viry, Kilian Le Corre, Thierry Robin +3
    Optics ExpressPeer-reviewedCC BY 4.0Full textOptics & photonicsHAL
  2. Millimeter-scale wide-field mid-infrared photothermal imaging enabled by a broadly tunable picosecond optical parametric oscillator
    Anooj Thayyil Raveendran, Supatcharee Cael, Anju Jose +2
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsarXiv
  3. High-power visible laser via injection locking to a photonic integrated circuit optical parametric oscillator
    Daniel Pimbi, Zhiquan Yuan, Ashish Chanana +4
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
  4. Spectral Theory of an Exactly Solvable Quantum-Optical Oscillator
    Sam Johar, Joseph Kraisler
    arXivPreprintarXiv licenceFull textAnalysis & PDEsMathematical physicsarXiv
  5. Quantum Battery Enhancement via Degenerate Optical Parametric Amplifier and Common Reservoirs
    Y. Y. Yang, H. N. Liu, Gangcheng Wang +2
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
BibTeX
@misc{blinova2026critical,
  title = {{Critical quantum metrology in the output of an optical parametric oscillator}},
  author = {Polina Blinova and Kai Wang},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.15974},
  eprint = {2609.15974},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.15974},
}
RIS
TY  - UNPB
TI  - Critical quantum metrology in the output of an optical parametric oscillator
AU  - Polina Blinova
AU  - Kai Wang
PY  - 2026
DA  - 2026/09/14
PB  - arXiv
DO  - 10.48550/arxiv.2609.15974
UR  - https://arxiv.org/abs/2609.15974
AB  - Many quantum sensors infer parameters from continuously emitted fields, yet in the presence of unmonitored loss, it is difficult to determine how much critical enhancement survives in the accessible output. In this work, we calculate the full frequency-resolved output quantum Fisher information (QFI) of a stationary vacuum-seeded optical parametric oscillator for cavity-detuning estimation. We show that, for any fixed nonzero unmonitored loss, the QFI of correlated sideband pairs grows quadratically with the mean intracavity photon number near threshold, but only within a spectral window that narrows inversely with that number; consequently, the spectrum-integrated output QFI rate scales asymptotically only linearly. We identify a far-detuned, near-threshold regime in which the monitored output alone asymptotically approaches the loss-imposed upper bound on the joint cavity-output QFI. We further determine the operating points that maximize the output QFI rate per intracavity photon and introduce a frequency-resolved homodyne strategy that maximizes the Fisher information obtainable from a single record. Our results establish an operational connection between critical enhancement and metrological information accessible in the output field, while providing concrete guidance for the design and readout of dissipative parametric sensors.
ER  -