Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 37 min ago
PreprintarXiv licencearXiv

Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift

Abstract

Clinical measurements are recorded for some patients but not others, at rates that differ across hospitals, and marginal conformal coverage does not ensure coverage within groups defined by missingness. We propose a missingness-aware conformal calibration procedure for mortality prediction under cross-hospital distribution shift. It selects a measurement on an independent sample, groups patients by whether that measurement is recorded, and applies Mondrian calibration within each group, so no calibration outcome is reused. We evaluate the procedure across hospitals in eICU and across care units within one MIMIC-IV hospital, using three predictors. Relative to pooled calibration, it reduces the average worst-group coverage gap on its selected groups in all six settings, with a median reduction of 1.9 percentage points; paired site-bootstrap intervals exclude zero in five. These gains do not extend uniformly. Calibration by predicted risk achieves smaller gaps on a broader panel of missingness groups, and when eICU hospitals are evaluated separately, the gain shrinks for all three predictors and reverses in sign for one. We explain this discrepancy with a hospital-level decomposition. Pooling reweights hospitals through a covariance between group shares and coverage errors, and lets errors of opposite sign cancel: weighting explains the reversal, and cancellation accounts for most of the attenuation for the other two predictors. Constructed population distributions show that pooled and within-hospital evaluations can rank calibration methods oppositely even without sampling noise. Pooled improvement alone therefore cannot establish better coverage within hospitals, even when the calibration groups are fixed.

Related

  1. Conformal Prediction for Dyadic Regression Under Complex Missingness
    Robert Lunde, Minjie Yang, Elizaveta Levina +1
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  2. Uncertainty aware prediction from incomplete clinical records: a conformal prediction study of Parkinsonian classification using C-OPN data
    Jiaqi Bi, Jialu Sun, Hanrui Dou +4
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  3. Particle-Based Conformal Prediction for Contact-Aware Uncertainty Calibration in Stratified Configuration Spaces
    Luís Marques, Kristian Popov, Dmitry Berenson
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
  4. CHOIR: heterogeneity-aware conformal prediction for crash injury severity across driver safety strata
    Amir Rafe, Subasish Das
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Pattern-Calibrated Multimodal Prediction under Blockwise Missingness
    Junhan Yu, Kejian Zhang, Doudou Zhou +1
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
BibTeX
@misc{you2026missingnessaware,
  title = {{Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift}},
  author = {Liang You and Dongwen Ou and Hengyu Shi and Siyuan Dai},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.30781},
  eprint = {2609.30781},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.30781},
}
RIS
TY  - UNPB
TI  - Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift
AU  - Liang You
AU  - Dongwen Ou
AU  - Hengyu Shi
AU  - Siyuan Dai
PY  - 2026
DA  - 2026/09/25
PB  - arXiv
DO  - 10.48550/arxiv.2609.30781
UR  - https://arxiv.org/abs/2609.30781
AB  - Clinical measurements are recorded for some patients but not others, at rates that differ across hospitals, and marginal conformal coverage does not ensure coverage within groups defined by missingness. We propose a missingness-aware conformal calibration procedure for mortality prediction under cross-hospital distribution shift. It selects a measurement on an independent sample, groups patients by whether that measurement is recorded, and applies Mondrian calibration within each group, so no calibration outcome is reused. We evaluate the procedure across hospitals in eICU and across care units within one MIMIC-IV hospital, using three predictors. Relative to pooled calibration, it reduces the average worst-group coverage gap on its selected groups in all six settings, with a median reduction of 1.9 percentage points; paired site-bootstrap intervals exclude zero in five. These gains do not extend uniformly. Calibration by predicted risk achieves smaller gaps on a broader panel of missingness groups, and when eICU hospitals are evaluated separately, the gain shrinks for all three predictors and reverses in sign for one. We explain this discrepancy with a hospital-level decomposition. Pooling reweights hospitals through a covariance between group shares and coverage errors, and lets errors of opposite sign cancel: weighting explains the reversal, and cancellation accounts for most of the attenuation for the other two predictors. Constructed population distributions show that pooled and within-hospital evaluations can rank calibration methods oppositely even without sampling noise. Pooled improvement alone therefore cannot establish better coverage within hospitals, even when the calibration groups are fixed.
ER  -