Effectiveness of Compartmentalized Expanded Polytetrafluoroethylene 3-wire Neural Conduit for Sciatic Nerve–directed Bundle Regeneration
7 affiliations
- 1From the Department of Plastic Surgery, University of Ioannina Faculty of Medicine: Panepistemio Ioanninon Tmema Iatrikes, Ioannina, Greece
- 2Private practice, Athens, Greece
- 3Laboratory of Cellular and Molecular Neurobiology-Stem Cells, Hellenic Pasteur Institute, Athens, Greece
- 4Human Stem Cell and Reprogramming Unit, Hellenic Pasteur Institute, Athens, Greece
- 5Physical Medicine and Rehabilitation Department, KAT General Hospital, Athens, Greece
- 6Department of Orthopaedic Surgery, University of Ioannina Faculty of Medicine: Panepistemio Ioanninon Tmema Iatrikes, Ioannina, Greece
- 7Department of Pathology, University of Ioannina Faculty of Medicine: Panepistemio Ioanninon Tmema Iatrikes, Ioannina, Greece.
Abstract
Background:: Peripheral nerve defects pose major reconstructive challenges when tension-free end-to-end repair is not feasible. Although autologous nerve grafting remains an ideal strategy for bridging nerve gaps, donor-site morbidity and limitations regarding graft availability stimulated the development of tissue-engineered nerve conduits. Attempting to improve fascicular guidance, compartmentalized conduit designs were proposed, promoting more organized axonal regeneration. The present study evaluates the reparative efficacy of a compartmentalized expanded polytetrafluoroethylene (e-PTFE) 3-wire neural conduit compared with established reconstructive approaches using a rat sciatic nerve injury model.
Methods:: Seventy-one (n = 71) adult rats were allocated into 5 experimental groups. Group A received end-to-end repair following sciatic nerve transection. Group B received a 1-cm autologous nerve graft. In groups C and D, a 1-cm segment was excised and reconstructed using an e-PTFE conduit incorporating 3 internal grooves corresponding to the sciatic fascicular pattern. In group D, conduits were enriched with Schwann cells. Group E underwent nerve transection without reconstruction (negative control). Regeneration was assessed until 180 days by kinematic analysis, gastrocnemius muscle mass ratio, electromyography, and histological evaluation.
Results:: Axonal regeneration and muscle reinnervation were achieved in all experimental groups, except in the negative control. Morphometric analysis revealed significant differences between all intervention groups and the control group (P < 0.05). Schwann cell–enriched conduits showed significantly greater axonal diameter than non-enriched conduits (P = 0.05).
Conclusions:: Compartmentalized e-PTFE conduits effectively supported peripheral nerve regeneration. Schwann cell enrichment offers important additional regenerative advantages, highlighting the potential of the proposed conduit for functional restitution after peripheral nerve injuries.
Related
- A stochastic model of compartmentalized intracellular signalling
- Compartmentalized Nanozyme Transduction Enables Regenerative Molecular Amplification for Multiplexed miRNA-Based Prostate Cancer Stratification
- Experimental trophic flexibility guides a compartmentalized genome-scale model of red microalgae Galdieria sulphuraria
- Spatial isotope tracing maps compartmentalized nutrient use across the adult fruit fly
- A medial entorhinal connectome reveals compartmentalized microcircuit architecture
BibTeX
@article{dalianoudis2026effectiveness,
title = {{Effectiveness of Compartmentalized Expanded Polytetrafluoroethylene 3-wire Neural Conduit for Sciatic Nerve–directed Bundle Regeneration}},
author = {Ioannis G. Dalianoudis and Florentia Papastefanaki and Ioannis-Alexandros Tzanos and Kyriaki Apostolidou and Marios D. Vekris and Anna Batistatou and Rebecca Matsas and Efstathios G. Lykoudis},
journal = {Plastic and Reconstructive Surgery Global Open},
year = {2026},
month = nov,
doi = {10.1097/gox.0000000000008235},
url = {https://doi.org/10.1097/gox.0000000000008235},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Effectiveness of Compartmentalized Expanded Polytetrafluoroethylene 3-wire Neural Conduit for Sciatic Nerve–directed Bundle Regeneration
AU - Ioannis G. Dalianoudis
AU - Florentia Papastefanaki
AU - Ioannis-Alexandros Tzanos
AU - Kyriaki Apostolidou
AU - Marios D. Vekris
AU - Anna Batistatou
AU - Rebecca Matsas
AU - Efstathios G. Lykoudis
PY - 2026
DA - 2026/11/12
JO - Plastic and Reconstructive Surgery Global Open
DO - 10.1097/gox.0000000000008235
UR - https://doi.org/10.1097/gox.0000000000008235
AB - Background:: Peripheral nerve defects pose major reconstructive challenges when tension-free end-to-end repair is not feasible. Although autologous nerve grafting remains an ideal strategy for bridging nerve gaps, donor-site morbidity and limitations regarding graft availability stimulated the development of tissue-engineered nerve conduits. Attempting to improve fascicular guidance, compartmentalized conduit designs were proposed, promoting more organized axonal regeneration. The present study evaluates the reparative efficacy of a compartmentalized expanded polytetrafluoroethylene (e-PTFE) 3-wire neural conduit compared with established reconstructive approaches using a rat sciatic nerve injury model. Methods:: Seventy-one (n = 71) adult rats were allocated into 5 experimental groups. Group A received end-to-end repair following sciatic nerve transection. Group B received a 1-cm autologous nerve graft. In groups C and D, a 1-cm segment was excised and reconstructed using an e-PTFE conduit incorporating 3 internal grooves corresponding to the sciatic fascicular pattern. In group D, conduits were enriched with Schwann cells. Group E underwent nerve transection without reconstruction (negative control). Regeneration was assessed until 180 days by kinematic analysis, gastrocnemius muscle mass ratio, electromyography, and histological evaluation. Results:: Axonal regeneration and muscle reinnervation were achieved in all experimental groups, except in the negative control. Morphometric analysis revealed significant differences between all intervention groups and the control group (P < 0.05). Schwann cell–enriched conduits showed significantly greater axonal diameter than non-enriched conduits (P = 0.05). Conclusions:: Compartmentalized e-PTFE conduits effectively supported peripheral nerve regeneration. Schwann cell enrichment offers important additional regenerative advantages, highlighting the potential of the proposed conduit for functional restitution after peripheral nerve injuries.
SN - 2169-7574
ER -