Latest-iteration self-expanding vs balloon-expandable transcatheter heart valves for failed surgical bioprostheses: The INNOVATE registry.
14 affiliations
- 1Department of Cardiology, IRCCS Policlinico San Donato, Piazza Edmondo Malan 2, San Donato Milanese, Milan 20097, Italy.
- 2Montefiore-Einstein Center for Heart and Vascular Care Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA.
- 3Unidad de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
- 4Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, Spain.
- 5MVZ Department Structural Heart Disease, Asklepios St. Georg Clinic, Hamburg, Germany.
- 6Department of Cardiovascular Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
- 7Interventional Cardiology, De Gasperis Cardio Center, Niguarda Hospital, Milan, Italy.
- 8School of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.
- 9Department of Cardiology, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy.
- 10Department of Cardiology, San Giovanni Evangelista Hospital, Tivoli, Italy.
- 11Division of Cardiology, University of Rome 'Tor Vergata', Rome, Italy.
- 12Department of Cardiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang Province, P.R. China.
- 13Department of Cardiology, University Hospital Alvaro Cunqueiro, Vigo, Spain.
- 14Department of Cardiology, Cardiovascular Research Group, University Hospital Alvaro Cunqueiro, Galicia Sur Health Research Institute (IIS Galicia Sur), Servizo Galego de Saude, University of Vigo, Vigo, Spain.
Abstract
Background
Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is increasingly performed in degenerated surgical bioprostheses, although data concerning the performance of latest iterations of transcatheter heart valves (THVs) are scarce.Aims
We aimed to compare procedural, clinical and haemodynamic outcomes of latest-generation THVs in ViV TAVI.Methods and results
This multicenter retrospective study included 381 consecutive patients undergoing ViV TAVI, 294 with self-expanding (SE), and 87 with a balloon expandable (BE) THV. Primary efficacy endpoints were Valve Academic Research Consortium (VARC)-3 technical and device success. Primary safety outcomes were all-cause death and re-hospitalization for heart failure (HF). Patients receiving SE valves were older (79 vs 75 years, P < .001). Time from surgery to ViV was longer in BE group (4 vs 3 years, P = .041). A numerically higher rate of coronary obstruction (4% vs 0%, P = .076) was observed in SE THVs, despite a more frequent coronary protection (24% vs 14%, P = .045). Technical (95% vs 98%, P = .380) and device success (89% vs 79%, P = .105) were similar. At 1 year, SE valves showed significantly lower mean gradients (14 ± 8 vs 21 ± 8 mmHg, P < .001). Rates of paravalvular leak and patient-prosthesis mismatch did not differ between groups. All-cause mortality (5% vs 4%, P = .928) and re-hospitalization for HF (4% vs 2%, P = .507) was also comparable among SE and BE, likewise myocardial infarction, stroke, and permanent pacemaker implantation.Conclusion
Latest iterations of SE and BE THVs provided favourable outcomes in ViV TAVI, without significant differences in safety/efficacy profile. SE platforms achieved lower residual gradients at 1 year.
Related
- Balloon-Expandable Vs Self-Expanding Valves for Transcatheter Aortic Valve Implantation in Internally Stented Surgical Valves
- Three-year outcomes of balloon-expandable valve-in-valve aortic valve implantation for failed transcatheter versus surgical valves
- Treatment of Failed Mitral Valve Bioprostheses or Repairs: Transcatheter Mitral Valve-in-Valve/Valve-in-Ring Versus Redo Surgical Mitral Valve Replacement
- Surgical aortic valve replacement-level aortotomy for self-expanding transcatheter aortic valve explantation
- Early Post-transcatheter Aortic Valve Implantation (TAVI) Haemodynamics With SAPIEN Balloon-Expandable and Evolut Self-Expanding Valve Platforms: A Retrospective Single-Centre Cohort Study.
BibTeX
@article{sisinni2026latestiteration,
title = {{Latest-iteration self-expanding vs balloon-expandable transcatheter heart valves for failed surgical bioprostheses: The INNOVATE registry.}},
author = {Antonio Sisinni and Antonio Popolo Rubbio and Azeem Latib and Ignacio J Amat Santos and Christina Brinkmann and Cristina Aurigemma and Claudio Montalto and Damiano Regazzoli and Carmine Musto and Giuseppe Massimo Sangiorgi and Zhou Yijiang and Rodrigo Estévez-Loureiro and Victor Alfonso Jimenez Diaz and Gaspare Sergio Cannone and Pier Pasquale Leone and Raffaele Del Maso and Alexandra M Rojas Sanchez and Nedy Brambilla and Francesco Burzotta and Jacopo A Oreglia and Joachim Schofer and Francesco Bedogni and Luca Testa},
journal = {European heart journal. Valvular and structural heart disease},
year = {2026},
month = jun,
doi = {10.1093/ehjvshd/xwag042},
url = {https://europepmc.org/article/MED/43053885},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - Latest-iteration self-expanding vs balloon-expandable transcatheter heart valves for failed surgical bioprostheses: The INNOVATE registry.
AU - Antonio Sisinni
AU - Antonio Popolo Rubbio
AU - Azeem Latib
AU - Ignacio J Amat Santos
AU - Christina Brinkmann
AU - Cristina Aurigemma
AU - Claudio Montalto
AU - Damiano Regazzoli
AU - Carmine Musto
AU - Giuseppe Massimo Sangiorgi
AU - Zhou Yijiang
AU - Rodrigo Estévez-Loureiro
AU - Victor Alfonso Jimenez Diaz
AU - Gaspare Sergio Cannone
AU - Pier Pasquale Leone
AU - Raffaele Del Maso
AU - Alexandra M Rojas Sanchez
AU - Nedy Brambilla
AU - Francesco Burzotta
AU - Jacopo A Oreglia
AU - Joachim Schofer
AU - Francesco Bedogni
AU - Luca Testa
PY - 2026
DA - 2026/06/01
JO - European heart journal. Valvular and structural heart disease
DO - 10.1093/ehjvshd/xwag042
UR - https://europepmc.org/article/MED/43053885
AB - Background Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is increasingly performed in degenerated surgical bioprostheses, although data concerning the performance of latest iterations of transcatheter heart valves (THVs) are scarce.Aims We aimed to compare procedural, clinical and haemodynamic outcomes of latest-generation THVs in ViV TAVI.Methods and results This multicenter retrospective study included 381 consecutive patients undergoing ViV TAVI, 294 with self-expanding (SE), and 87 with a balloon expandable (BE) THV. Primary efficacy endpoints were Valve Academic Research Consortium (VARC)-3 technical and device success. Primary safety outcomes were all-cause death and re-hospitalization for heart failure (HF). Patients receiving SE valves were older (79 vs 75 years, P < .001). Time from surgery to ViV was longer in BE group (4 vs 3 years, P = .041). A numerically higher rate of coronary obstruction (4% vs 0%, P = .076) was observed in SE THVs, despite a more frequent coronary protection (24% vs 14%, P = .045). Technical (95% vs 98%, P = .380) and device success (89% vs 79%, P = .105) were similar. At 1 year, SE valves showed significantly lower mean gradients (14 ± 8 vs 21 ± 8 mmHg, P < .001). Rates of paravalvular leak and patient-prosthesis mismatch did not differ between groups. All-cause mortality (5% vs 4%, P = .928) and re-hospitalization for HF (4% vs 2%, P = .507) was also comparable among SE and BE, likewise myocardial infarction, stroke, and permanent pacemaker implantation.Conclusion Latest iterations of SE and BE THVs provided favourable outcomes in ViV TAVI, without significant differences in safety/efficacy profile. SE platforms achieved lower residual gradients at 1 year.
SN - 2977-8565
ER -