Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BYBone & joint research

Influence of stem undersizing during direct anterior approach for total hip arthroplasty on periprosthetic bone biomechanics : a finite element analysis

  1. 1First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, Brno, Czechia
  2. 2Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czechia

Abstract

Aims: Stem undersizing during cementless total hip arthroplasty (THA) may occur more frequently when the procedure is performed through the direct anterior approach (DAA) because of limited femoral exposure. Insufficient stem–bone contact may compromise primary stability and alter load transfer in the proximal femur. The aim was to investigate the biomechanical effects of femoral stem undersizing on periprosthetic bone using finite element analysis. A secondary objective was to evaluate whether the presence of a femoral stem collar modifies these biomechanical effects.

Methods: Patient-specific finite element models of the full femur were generated from CT data. Eight finite element models were analyzed, combining four implantation configurations of the AMIStem-P designs (Adequate Fit, Adequate Fit–Collared, Undersized, and Undersized–Collared) with two cancellous bone density conditions, representing 100% and 90% cancellous bone density. A hip joint force representing the peak loading phase during normal walking/single-leg support was applied. Strain intensity in periprosthetic trabecular bone was assessed according to Frost’s mechanostat theory, and von Mises stress distribution in the femoral stem was evaluated.

Results: Stem undersizing markedly increased strain intensity in the periprosthetic trabecular bone and enlarged regions exceeding the mechanostat overload threshold (> 3,000 µε). Adequate stem–bone fit with cortical support substantially reduced the volume of overloaded bone tissue. The presence of a collar reduced strain levels, particularly in undersized configurations, indicating improved proximal load transfer. Reduced cancellous bone density resulted in a moderate additional increase in strain. Simulated load reduction markedly decreased periprosthetic strain levels. Implant stresses remained well below material limits.

Conclusion: Femoral stem undersizing may substantially increase strain within the periprosthetic trabecular bone and enlarge regions exposed to overload conditions. Achieving adequate stem–bone fit with cortical support was associated with a marked reduction in periprosthetic bone strain. The presence of a collar appeared to partially mitigate the adverse mechanical effects of undersizing by improving proximal load transfer.

Cite this article: Bone Joint Res 2026;15(11):1354–1363.

Related

  1. Early Periprosthetic Femoral Fractures and Stem Subsidence After Direct Anterior Total Hip Arthroplasty Using a Collared, Fully Hydroxyapatite-Coated Stem
    Hiroshige Hamada, Yoko Miura, Taishi Ninomiya +1
    Journal of OrthopaedicsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMCEurope PMC
  2. Culture-Specific Outcomes of Intra-Articular Antibiotic Infusion With Implant-Retaining Debridement for Periprosthetic Joint Infection After Unicompartmental Knee Arthroplasty
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. From Measured Accuracy to Patient Outcome: Navigation in Total Hip Arthroplasty and Molecular Diagnosis of Periprosthetic Joint Infection: A Narrative Review
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Extensor Mechanism Reconstruction Following Periprosthetic Joint Infection After Total Knee Arthroplasty: A Systematic Review
    Camilla Prosenz, Hisham Fansa, Hannah Engel +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Implant sonication supporting the diagnosis of low-grade periprosthetic joint infection following reverse shoulder arthroplasty: a case report
    Gi-Won Seo, Kunil Seo, Yong-Beom Kim
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{liskay2026influence,
  title = {{Influence of stem undersizing during direct anterior approach for total hip arthroplasty on periprosthetic bone biomechanics : a finite element analysis}},
  author = {Jakub Liskay and Petr Marcián and Vasileios Apostolopoulos and Luboš Nachtnebl and Tomáš Tomáš},
  journal = {Bone \& joint research},
  year = {2026},
  month = nov,
  doi = {10.1302/2046-3758.1511.bjr-2026-0175.r1},
  url = {https://europepmc.org/article/PMC/PMC13754448},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Influence of stem undersizing during direct anterior approach for total hip arthroplasty on periprosthetic bone biomechanics : a finite element analysis
AU  - Jakub Liskay
AU  - Petr Marcián
AU  - Vasileios Apostolopoulos
AU  - Luboš Nachtnebl
AU  - Tomáš Tomáš
PY  - 2026
DA  - 2026/11/01
JO  - Bone & joint research
DO  - 10.1302/2046-3758.1511.bjr-2026-0175.r1
UR  - https://europepmc.org/article/PMC/PMC13754448
AB  - Aims: Stem undersizing during cementless total hip arthroplasty (THA) may occur more frequently when the procedure is performed through the direct anterior approach (DAA) because of limited femoral exposure. Insufficient stem–bone contact may compromise primary stability and alter load transfer in the proximal femur. The aim was to investigate the biomechanical effects of femoral stem undersizing on periprosthetic bone using finite element analysis. A secondary objective was to evaluate whether the presence of a femoral stem collar modifies these biomechanical effects.  Methods: Patient-specific finite element models of the full femur were generated from CT data. Eight finite element models were analyzed, combining four implantation configurations of the AMIStem-P designs (Adequate Fit, Adequate Fit–Collared, Undersized, and Undersized–Collared) with two cancellous bone density conditions, representing 100% and 90% cancellous bone density. A hip joint force representing the peak loading phase during normal walking/single-leg support was applied. Strain intensity in periprosthetic trabecular bone was assessed according to Frost’s mechanostat theory, and von Mises stress distribution in the femoral stem was evaluated.  Results: Stem undersizing markedly increased strain intensity in the periprosthetic trabecular bone and enlarged regions exceeding the mechanostat overload threshold (> 3,000 µε). Adequate stem–bone fit with cortical support substantially reduced the volume of overloaded bone tissue. The presence of a collar reduced strain levels, particularly in undersized configurations, indicating improved proximal load transfer. Reduced cancellous bone density resulted in a moderate additional increase in strain. Simulated load reduction markedly decreased periprosthetic strain levels. Implant stresses remained well below material limits.  Conclusion: Femoral stem undersizing may substantially increase strain within the periprosthetic trabecular bone and enlarge regions exposed to overload conditions. Achieving adequate stem–bone fit with cortical support was associated with a marked reduction in periprosthetic bone strain. The presence of a collar appeared to partially mitigate the adverse mechanical effects of undersizing by improving proximal load transfer.  Cite this article: Bone Joint Res 2026;15(11):1354–1363.
SN  - 2046-3758
ER  -