Instrument-Level Validation of Upper Sideband Syntonization Concept
Abstract
Upper Sideband Syntonization (USBS) is a two-way frequency-transfer concept proposed by the European Space Agency for distributed space radio interferometric systems. Previous investigations validated the concept primarily through frequency-stability and phase-transfer measurements. This work demonstrates the first end-to-end instrument-level validation of the USBS concept through coherent W-band cross-correlation measurements and image reconstruction. A P=2 USBS breadboard was integrated with a W-band radio interferometer developed for this test. The synchronized local oscillators (LOs) were evaluated through long-term cross-correlation measurements and coherent imaging of a point-like noise source. The results were compared with those obtained using a conventional common LO as well as two independent free-running LOs. The USBS-derived LOs maintained coherence over 500 s of cumulative effective integration time acquired over approximately five days of elapsed time and preserved inter-session phase stability over measurements spanning 40 days. The reconstructed image is nearly indistinguishable from that obtained with a common LO, whereas independent free-running LOs lead to severe coherence degradation, image distortion, and approximately 38 dB loss of peak response. The results demonstrate that USBS preserves the interferometric coherence required for W-band imaging and present the first end-to-end instrument-level validation of the USBS syntonization concept for future distributed space radio interferometric missions
Related
- The concept of thought forms as a consequence of the Acta Universi hypothesis on the nature of dark energy and data from the Dark Energy Spectroscopic Instrument (DESI)
- Lunar Dielectric Analyzer (LDA) for the Artemis First Landing Mission: Instrument Design and Operational Concept for In Situ Permittivity Measurements
- Concept Study of the Heterodyne Spectroscopy Instrument (HSI) for the Proposed Far-IR Spectroscopy Space Telescope (FIRSST)
- Confronting the Higgsino Interpretation of the LZ Event with the High-Energy Sideband
- HARMONI@ELT: instrument design, performance, and science capabilities
BibTeX
@misc{kudriashov2026instrumentlevel,
title = {{Instrument-Level Validation of Upper Sideband Syntonization Concept}},
author = {Volodymyr Kudriashov and Manuel Martin-Neira},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.10807},
eprint = {2609.10807},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.10807},
}
RIS
TY - UNPB
TI - Instrument-Level Validation of Upper Sideband Syntonization Concept
AU - Volodymyr Kudriashov
AU - Manuel Martin-Neira
PY - 2026
DA - 2026/09/09
PB - arXiv
DO - 10.48550/arxiv.2609.10807
UR - https://arxiv.org/abs/2609.10807
AB - Upper Sideband Syntonization (USBS) is a two-way frequency-transfer concept proposed by the European Space Agency for distributed space radio interferometric systems. Previous investigations validated the concept primarily through frequency-stability and phase-transfer measurements. This work demonstrates the first end-to-end instrument-level validation of the USBS concept through coherent W-band cross-correlation measurements and image reconstruction. A P=2 USBS breadboard was integrated with a W-band radio interferometer developed for this test. The synchronized local oscillators (LOs) were evaluated through long-term cross-correlation measurements and coherent imaging of a point-like noise source. The results were compared with those obtained using a conventional common LO as well as two independent free-running LOs. The USBS-derived LOs maintained coherence over 500 s of cumulative effective integration time acquired over approximately five days of elapsed time and preserved inter-session phase stability over measurements spanning 40 days. The reconstructed image is nearly indistinguishable from that obtained with a common LO, whereas independent free-running LOs lead to severe coherence degradation, image distortion, and approximately 38 dB loss of peak response. The results demonstrate that USBS preserves the interferometric coherence required for W-band imaging and present the first end-to-end instrument-level validation of the USBS syntonization concept for future distributed space radio interferometric missions
ER -