Comparative efficacy of “Superimposed Line” sign and maxillary gap in first-trimester screening for cleft palate: a retrospective case-control study
- 1Department of Ultrasound, Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan, China
- 2Department of Otolaryngology, Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan, China
Abstract
BackgroundTo compare the diagnostic performance of two first-trimester sonographic markers—the “superimposed line” sign and the maxillary gap (GAP)—for screening fetal cleft palate, and to evaluate their underlying physical mechanisms (acoustic interface integrity vs. mechanical displacement).MethodsWe conducted a retrospective case-control study of 120 fetuses (60 confirmed cleft palate cases, 60 matched controls) at 11–13+6 weeks. We analyzed the standard mid-sagittal plane used for Nuchal Translucency (NT) measurement. Diagnostic criteria were defined as the absence of the echogenic “superimposed line” or a GAP width ≥1.5 mm. We compared sensitivity, specificity, and inter-method agreement using McNemar's test and Cohen's Kappa.ResultsThe “superimposed line” sign demonstrated a sensitivity of 90.0% (54/60; 95% CI: 79.5–96.2%) and specificity of 100%. The GAP method demonstrated a sensitivity of 78.3% (47/60; 95% CI: 65.8–87.9%) and specificity of 100%. The “superimposed line” sign detected significantly more cases than the GAP method (χ2 = 90.81, P < 0.001). Discordant analysis revealed that in 7 cases, the cleft disrupted the acoustic interface (absent line) but failed to cause significant vomer displacement (normal GAP).ConclusionsThe “superimposed line” sign offers superior diagnostic sensitivity compared to the maxillary gap in the first trimester. It detects bony disruption directly via acoustic principles, proving effective even when mechanical displacement is minimal. We recommend integrating this sign into routine NT screening protocols.
Related
- First-Trimester Pregnancy Tumour of the Anterior Maxillary Gingiva: A Case Report of Lobular Capillary Hemangioma.
- Structural Fetal Anomalies Identified During First-Trimester Screening: A Single-Centre Experience in Romania
- Mapping Preeclampsia Risk Thresholds to Screen-Positive Rates in Routine First-Trimester Screening: A Single-Centre Audit
- Preoperative Staphylococcus aureus nasal screening and decolonization for the prevention of periprosthetic joint infection in elective total joint arthroplasty: A single-center retrospective comparative study.
- Five-Year Marginal Bone-Level Changes Around Immediately Loaded or Immediately Restored Implants After Maxillary Sinus Floor Elevation: A Retrospective Cohort Analysis of Three Implant-Site Preparation Techniques
BibTeX
@article{hu2026comparative,
title = {{Comparative efficacy of “Superimposed Line” sign and maxillary gap in first-trimester screening for cleft palate: a retrospective case-control study}},
author = {Lirong Hu and Cong Chen and Qin Hu and Qinyi Jiang and Yi Hu and Mengqi Wu and Yuanyuan Yue},
journal = {Frontiers in Medicine},
year = {2026},
month = nov,
doi = {10.3389/fmed.2026.1818315},
url = {https://doi.org/10.3389/fmed.2026.1818315},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparative efficacy of “Superimposed Line” sign and maxillary gap in first-trimester screening for cleft palate: a retrospective case-control study
AU - Lirong Hu
AU - Cong Chen
AU - Qin Hu
AU - Qinyi Jiang
AU - Yi Hu
AU - Mengqi Wu
AU - Yuanyuan Yue
PY - 2026
DA - 2026/11/18
JO - Frontiers in Medicine
DO - 10.3389/fmed.2026.1818315
UR - https://doi.org/10.3389/fmed.2026.1818315
AB - BackgroundTo compare the diagnostic performance of two first-trimester sonographic markers—the “superimposed line” sign and the maxillary gap (GAP)—for screening fetal cleft palate, and to evaluate their underlying physical mechanisms (acoustic interface integrity vs. mechanical displacement).MethodsWe conducted a retrospective case-control study of 120 fetuses (60 confirmed cleft palate cases, 60 matched controls) at 11–13+6 weeks. We analyzed the standard mid-sagittal plane used for Nuchal Translucency (NT) measurement. Diagnostic criteria were defined as the absence of the echogenic “superimposed line” or a GAP width ≥1.5 mm. We compared sensitivity, specificity, and inter-method agreement using McNemar's test and Cohen's Kappa.ResultsThe “superimposed line” sign demonstrated a sensitivity of 90.0% (54/60; 95% CI: 79.5–96.2%) and specificity of 100%. The GAP method demonstrated a sensitivity of 78.3% (47/60; 95% CI: 65.8–87.9%) and specificity of 100%. The “superimposed line” sign detected significantly more cases than the GAP method (χ2 = 90.81, P < 0.001). Discordant analysis revealed that in 7 cases, the cleft disrupted the acoustic interface (absent line) but failed to cause significant vomer displacement (normal GAP).ConclusionsThe “superimposed line” sign offers superior diagnostic sensitivity compared to the maxillary gap in the first trimester. It detects bony disruption directly via acoustic principles, proving effective even when mechanical displacement is minimal. We recommend integrating this sign into routine NT screening protocols.
SN - 2296-858X
ER -