Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 12 min ago
PreprintCC BY-NC-ND 4.0arXiv

Real-time monitoring of LHCb beam spot properties based on FPGA hit reconstruction

Abstract

We present a real-time trackless method to monitor the centre of the LHCb luminous region and the relative alignment of the two halves of the LHCb Vertex Locator, using cluster counts accumulated in selected regions of the detector and processed in firmware. A Principal Component Analysis performed on simulated data yields a set of weight vectors that reduce the position estimators to scalar products of the counter rates, executable with negligible computational overhead. With pp collision data from 2024, the transverse position of the luminous region is reconstructed with a statistical precision of approximately 4 micrometre per coordinate in a 90 millisecond accumulation window. A measurement of the longitudinal centre is demonstrated with a statistical precision of a few millimetres in simulated studies. The introduction of run-time configurable firmware counters has been studied in simulation to improve the transverse and longitudinal resolutions by a factor of three with respect to the fixed-geometry baseline.

Related

  1. Real-time lepton identification at LHCb in Run 3 using Lipschitz neural networks
    Adrian Casais Vidal, Kate A. Richardson, Maarten Van Veghel +3
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  2. Measurements of time-dependent b-hadron properties in LHCb
    Lucas Foreman
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  3. Reflector‐Free, Highly Confined Love‐Like SAWs Enabled by a Phononic Metasurface for Real‐Time Monitoring of Cell Dynamics
    Jessica Monaldi, Julio A Iglesias Martínez, Francis Kosior +4
    Advanced Functional MaterialsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral physicsHAL
  4. RTLViT: real-time lensless reconstruction with a lightweight vision transformer
    Leyla A. Kabuli, Vasilisa Ponomarenko, Laura Waller
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
  5. Real-time Track Reconstruction with FPGAs: an example from MUonE
    Michael McGinnis, David Monk, Kristian Hahn
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsarXiv
BibTeX
@misc{cordova2026realtime,
  title = {{Real-time monitoring of LHCb beam spot properties based on FPGA hit reconstruction}},
  author = {Giulio Cordova and Elena Graverini and Daniele Passaro and Federico Lazzari and Michael J. Morello and Giovanni Punzi},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.17932},
  eprint = {2610.17932},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.17932},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Real-time monitoring of LHCb beam spot properties based on FPGA hit reconstruction
AU  - Giulio Cordova
AU  - Elena Graverini
AU  - Daniele Passaro
AU  - Federico Lazzari
AU  - Michael J. Morello
AU  - Giovanni Punzi
PY  - 2026
DA  - 2026/10/13
PB  - arXiv
DO  - 10.48550/arxiv.2610.17932
UR  - https://arxiv.org/abs/2610.17932
AB  - We present a real-time trackless method to monitor the centre of the LHCb luminous region and the relative alignment of the two halves of the LHCb Vertex Locator, using cluster counts accumulated in selected regions of the detector and processed in firmware. A Principal Component Analysis performed on simulated data yields a set of weight vectors that reduce the position estimators to scalar products of the counter rates, executable with negligible computational overhead. With pp collision data from 2024, the transverse position of the luminous region is reconstructed with a statistical precision of approximately 4 micrometre per coordinate in a 90 millisecond accumulation window. A measurement of the longitudinal centre is demonstrated with a statistical precision of a few millimetres in simulated studies. The introduction of run-time configurable firmware counters has been studied in simulation to improve the transverse and longitudinal resolutions by a factor of three with respect to the fixed-geometry baseline.
ER  -