Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY-NC-NDPlastic and reconstructive surgery. Global open

Robotic Versus Endoscopic Approach in Single-port Nipple-sparing Mastectomy With Direct-to-implant Prepectoral Breast Reconstruction.

  1. 1From the Division of Breast Surgery, Department of General Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China.
  2. 2Division of Hepatobiliary and Pancreatic Surgery, Department of General Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China.

Abstract

Background

This study compares surgical and implant-related outcomes between robotic and endoscopic approaches in single-port nipple-sparing mastectomy with direct-to-implant prepectoral breast reconstruction.Methods

In this retrospective cohort study, 54 patients undergoing nipple-sparing mastectomy with prepectoral reconstruction were divided into a robotic group (n = 21) and an endoscopic group (n = 33). Perioperative variables, including operative time, blood loss, drainage duration, hospital stay, and costs, as well as postoperative complications, were analyzed and compared between the 2 groups.Results

Median follow-up was 4.45 months for the robotic group and 8.73 months for the endoscopic group. The robotic approach required significantly longer operative time (244.32 ± 43.10 versus 178.72 ± 47.53 min, P < 0.001) and incurred substantially higher cost (US $14,464.77 ± $503.38 versus $10,303.79 ± $1017.26, P < 0.001). No significant differences were observed in intraoperative blood loss, length of hospital stay, drainage duration, or postoperative complication rates between the 2 groups.Conclusions

Robot-assisted nipple-sparing mastectomy with direct-to-implant prepectoral reconstruction is currently associated with longer operative time and higher cost compared with the endoscopic approach. Larger prospective studies with extended follow-up are needed to assess its oncological safety and aesthetic outcomes.

Related

  1. Long-term oncological outcomes after nipple-sparing mastectomy and implant-based immediate breast reconstruction in a population-based cohort of breast cancer patients
    BJS openPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMC
  2. Bilateral risk-reducing nipple-sparing mastectomy with implant-based reconstruction after previous breast-conserving treatment including radiotherapy: an exploratory multicenter cohort study
    Francisco Pimentel Cavalcante, Marcelo Antonini, Antonio L. Frasson +21
    BMC SurgeryPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  3. Peri-areolar dermal reinforcement to prevent prosthetic-related complications in prepectoral reconstruction with a compromised nipple-areola complex: a surgical technique
    Joon-Sung Lee, Sang-Oh Lee, Du-Hyong Cho +2
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. A New Approach to Nipple-Sparing Mastectomy for Patients with Ptotic Breasts: A Single-Center, Retrospective Analysis of Feasibility and Treatment Outcomes
    Paweł Pyka, Andrzej Frejnagel, Dzmitry Karkotka +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefEurope PMC
  5. Nipple or skin-sparing mastectomy flap: can preoperative breast-MRI predict post-operative complications?
    L. I. Sgaramella, A. Pasculli, F. P. Prete +35
    Updates in SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{li2026robotic,
  title = {{Robotic Versus Endoscopic Approach in Single-port Nipple-sparing Mastectomy With Direct-to-implant Prepectoral Breast Reconstruction.}},
  author = {Mengxin Li and Guangqian Shen and Shan Li and Hongchuan Jiang and Ren Lang and Zihan Wang},
  journal = {Plastic and reconstructive surgery. Global open},
  year = {2026},
  month = nov,
  doi = {10.1097/gox.0000000000008188},
  url = {https://europepmc.org/article/MED/43061655},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Robotic Versus Endoscopic Approach in Single-port Nipple-sparing Mastectomy With Direct-to-implant Prepectoral Breast Reconstruction.
AU  - Mengxin Li
AU  - Guangqian Shen
AU  - Shan Li
AU  - Hongchuan Jiang
AU  - Ren Lang
AU  - Zihan Wang
PY  - 2026
DA  - 2026/11/19
JO  - Plastic and reconstructive surgery. Global open
DO  - 10.1097/gox.0000000000008188
UR  - https://europepmc.org/article/MED/43061655
AB  - Background  This study compares surgical and implant-related outcomes between robotic and endoscopic approaches in single-port nipple-sparing mastectomy with direct-to-implant prepectoral breast reconstruction.Methods  In this retrospective cohort study, 54 patients undergoing nipple-sparing mastectomy with prepectoral reconstruction were divided into a robotic group (n = 21) and an endoscopic group (n = 33). Perioperative variables, including operative time, blood loss, drainage duration, hospital stay, and costs, as well as postoperative complications, were analyzed and compared between the 2 groups.Results  Median follow-up was 4.45 months for the robotic group and 8.73 months for the endoscopic group. The robotic approach required significantly longer operative time (244.32 ± 43.10 versus 178.72 ± 47.53 min, P < 0.001) and incurred substantially higher cost (US $14,464.77 ± $503.38 versus $10,303.79 ± $1017.26, P < 0.001). No significant differences were observed in intraoperative blood loss, length of hospital stay, drainage duration, or postoperative complication rates between the 2 groups.Conclusions  Robot-assisted nipple-sparing mastectomy with direct-to-implant prepectoral reconstruction is currently associated with longer operative time and higher cost compared with the endoscopic approach. Larger prospective studies with extended follow-up are needed to assess its oncological safety and aesthetic outcomes.
SN  - 2169-7574
ER  -