Skip to content
DraconiticResearch
Search Sources API
190,332 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY-NC-ND 4.0Scientific Reports

Deep learning based edge segmentation and classification for plasterboard defect detection

Abstract

This study presents a two-stage framework for binary plasterboard quality inspection that combines edge-region-of-interest (ROI) segmentation with lightweight classification. A production-line dataset of 5,557 images was acquired using an operator-triggered single-board-computer imaging system. On the 916-image manually masked subset, TransAttUNet produced higher ROI-overlap and boundary metrics than U-Net. The proposed MobileNetV2-MobileViT classifier contains 3.91 million parameters and was evaluated on a held-out set of 838 images, achieving 97.37% overall accuracy and 96.99% balanced accuracy. It achieved the highest accuracy among the evaluated transfer-learning baselines under the shared test protocol. Raspberry Pi 4 was used for image acquisition only; on-device inference, latency, memory, and power were not evaluated. Accordingly, the system should be interpreted as a compact, deployment-oriented framework that requires device-level validation before claims of real-time operation can be made.

Related

  1. Deep Learning for Real-Time Image Interpretation in Arthroscopy: A Systematic Review of Classification, Segmentation, and Detection Tasks
    Christopher Lasslett, Rohan Reddy, Gayathri Giritharan +5
    Eurasian Journal of MedicinePeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Multi-Backbone U-Net segmentation and interpretable hybrid deep learning classification for lung cancer detection in chest CT images
    Alireza Golkarieh, Kiana Kiashemshaki, Sajjad Rezvani Boroujeni +3
    BMC Pulmonary MedicinePeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  3. Multi-task deep learning framework for brain tumor classification and segmentation using ensemble feature extraction
    Retinderdeep Singh, Chander Prabha, Shahab Abdulla
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textNeurologyCrossref
  4. Boundary-aware multi-scale residual learning with hybrid radiomic–deep fusion for lung tumor segmentation and classification
    M. Sutharsan, K. R. Kavitha
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCrossref
  5. Deep learning-based segmentation, grading and genotype classification of glioma: a literature analysis
    Weihan Song, Yuan Hu, Yi Wang +3
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
BibTeX
@article{teke2026deep,
  title = {{Deep learning based edge segmentation and classification for plasterboard defect detection}},
  author = {Mustafa Teke and Mehmet Demir},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-76925-8},
  url = {https://www.nature.com/articles/s41598-026-76925-8},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Deep learning based edge segmentation and classification for plasterboard defect detection
AU  - Mustafa Teke
AU  - Mehmet Demir
PY  - 2026
DA  - 2026/10/20
JO  - Scientific Reports
DO  - 10.1038/s41598-026-76925-8
UR  - https://www.nature.com/articles/s41598-026-76925-8
AB  - This study presents a two-stage framework for binary plasterboard quality inspection that combines edge-region-of-interest (ROI) segmentation with lightweight classification. A production-line dataset of 5,557 images was acquired using an operator-triggered single-board-computer imaging system. On the 916-image manually masked subset, TransAttUNet produced higher ROI-overlap and boundary metrics than U-Net. The proposed MobileNetV2-MobileViT classifier contains 3.91 million parameters and was evaluated on a held-out set of 838 images, achieving 97.37% overall accuracy and 96.99% balanced accuracy. It achieved the highest accuracy among the evaluated transfer-learning baselines under the shared test protocol. Raspberry Pi 4 was used for image acquisition only; on-device inference, latency, memory, and power were not evaluated. Accordingly, the system should be interpreted as a compact, deployment-oriented framework that requires device-level validation before claims of real-time operation can be made.
SN  - 2045-2322
ER  -