Skip to content
DraconiticResearch
Search Sources API
223,421 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY 4.0Cureus

Accuracy of the Final Growth Ultrasound in Predicting Birthweight Centile in Women With Class III Obesity: A Retrospective Cohort Study

  1. 1Obstetrics and Gynaecology, Aneurin Bevan University Health Board, Gwent, GBR
  2. 2Emergency Medicine, Midland Metropolitan University Hospital, Smethwick, GBR
  3. 3Obstetrics and Gynaecology, The Grange University Hospital, Cwmbran, GBR

Abstract

Introduction

This study evaluated agreement between final third-trimester ultrasound estimated fetal weight (EFW) centile and subsequent birthweight centile in singleton pregnancies among women with class III obesity (body mass index (BMI) ≥40 kg/m²). Secondary objectives were to assess antenatal detection of small-for-gestational-age (SGA) and large-for-gestational-age (LGA) infants and associations of maternal BMI and scan-to-delivery interval with centile prediction error.

Methods

We conducted a retrospective cohort study of singleton pregnancies in women with booking BMI ≥40 kg/m². Agreement between final ultrasound EFW centile and birthweight centile was assessed using centile differences, correlation, SGA/appropriate-for-gestational-age (AGA)/LGA categorical agreement, and weighted Cohen’s kappa. Secondary analyses assessed diagnostic performance for SGA and LGA and associations of maternal BMI and scan-to-delivery interval with centile error.

Results

A total of 245 pregnancies had complete data. Mean maternal BMI was 44.8 kg/m², and mean scan-to-delivery interval was 14.4 days. EFW centile was positively correlated with birthweight centile (r = 0.732, p < 0.001). The median absolute centile difference was 13.1 centiles, and the mean signed difference was +3.6 centiles (95% confidence interval (CI) 1.0-6.2). Overall SGA/AGA/LGA category agreement was 82.4% (weighted κ = 0.502). Sensitivity was 26.9% for SGA and 46.9% for LGA, with specificities of 99.5% and 97.2%, respectively. Absolute centile error did not differ significantly across BMI or scan-to-delivery interval groups.

Conclusions

Final third-trimester ultrasound EFW centile was positively correlated with birthweight centile in women with class III obesity, but clinically important individual discrepancies remained. The final scan had high specificity but low sensitivity for identifying infants subsequently born SGA or LGA. Increasing BMI within the class III obesity range and scan-to-delivery interval were not significantly associated with greater centile error.

Related

  1. Diagnostic Accuracy of Multiparametric Ultrasound Versus Cross-Sectional Imaging for Differentiating Benign and Malignant Cervical Lymph Nodes: A Histopathology-Referenced Retrospective Study
    Inva Muçi, Steffen Dommerich, Philipp Arens +5
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Ultrasound parameters for predicting high bleeding risk and efficacy of uterine artery embolization in gestational sac-type cesarean scar pregnancy: a retrospective single-center study
    Quanlin Ren, Tian Tian, Hong Luo
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  3. Comparison of ultrasound accuracy versus clinical fetal weight estimation – a retrospective cross-sectional study
    Agnieszka A. Strojny, Stepan Feduniw, Arkadiusz Baran +7
    Ginekologia PolskaPeer-reviewedCC BY-NC-NDFull textObstetrics, gynaecology & paediatricsDOAJ
  4. Post-surgical abdominal wall endometriosis: a retrospective cohort study on clinical features, ultrasound accuracy and recurrence
    Shutong Lin, Lu Yu, Zhenglin Mou +2
    Frontiers in MedicinePeer-reviewedCC BY 4.0Full textObstetrics, gynaecology & paediatricsPMC
  5. A stage-based dynamic model for predicting bronchopulmonary dysplasia in very preterm infants using longitudinal lung ultrasound: a retrospective cohort study
    Huihui Yang, Xiongpeng He, Xijie Xu +3
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMCEurope PMCPMC
BibTeX
@article{mahurkar2026accuracy,
  title = {{Accuracy of the Final Growth Ultrasound in Predicting Birthweight Centile in Women With Class III Obesity: A Retrospective Cohort Study}},
  author = {Supreet Mahurkar and Shermin Riaz and Bojana Salovic and Soneya Chowdhury and Anjali Anjali and Sajitha Parveen},
  journal = {Cureus},
  year = {2026},
  month = nov,
  doi = {10.7759/cureus.119371},
  url = {https://doi.org/10.7759/cureus.119371},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Accuracy of the Final Growth Ultrasound in Predicting Birthweight Centile in Women With Class III Obesity: A Retrospective Cohort Study
AU  - Supreet Mahurkar
AU  - Shermin Riaz
AU  - Bojana Salovic
AU  - Soneya Chowdhury
AU  - Anjali Anjali
AU  - Sajitha Parveen
PY  - 2026
DA  - 2026/11/09
JO  - Cureus
DO  - 10.7759/cureus.119371
UR  - https://doi.org/10.7759/cureus.119371
AB  - Introduction  This study evaluated agreement between final third-trimester ultrasound estimated fetal weight (EFW) centile and subsequent birthweight centile in singleton pregnancies among women with class III obesity (body mass index (BMI) ≥40 kg/m²). Secondary objectives were to assess antenatal detection of small-for-gestational-age (SGA) and large-for-gestational-age (LGA) infants and associations of maternal BMI and scan-to-delivery interval with centile prediction error.  Methods  We conducted a retrospective cohort study of singleton pregnancies in women with booking BMI ≥40 kg/m². Agreement between final ultrasound EFW centile and birthweight centile was assessed using centile differences, correlation, SGA/appropriate-for-gestational-age (AGA)/LGA categorical agreement, and weighted Cohen’s kappa. Secondary analyses assessed diagnostic performance for SGA and LGA and associations of maternal BMI and scan-to-delivery interval with centile error.  Results  A total of 245 pregnancies had complete data. Mean maternal BMI was 44.8 kg/m², and mean scan-to-delivery interval was 14.4 days. EFW centile was positively correlated with birthweight centile (r = 0.732, p < 0.001). The median absolute centile difference was 13.1 centiles, and the mean signed difference was +3.6 centiles (95% confidence interval (CI) 1.0-6.2). Overall SGA/AGA/LGA category agreement was 82.4% (weighted κ = 0.502). Sensitivity was 26.9% for SGA and 46.9% for LGA, with specificities of 99.5% and 97.2%, respectively. Absolute centile error did not differ significantly across BMI or scan-to-delivery interval groups.  Conclusions  Final third-trimester ultrasound EFW centile was positively correlated with birthweight centile in women with class III obesity, but clinically important individual discrepancies remained. The final scan had high specificity but low sensitivity for identifying infants subsequently born SGA or LGA. Increasing BMI within the class III obesity range and scan-to-delivery interval were not significantly associated with greater centile error.
SN  - 2168-8184
ER  -