Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 14 min ago
Peer-reviewedCC BY-NC-SARevue des Sciences de la Santé

Évaluation intégrée de la qualité physico-chimique et microbiologique des eaux du district d'Isandra (Madagascar) par couplage de la txrf et de la modélisation par logique floue

4 affiliations
  1. 1Industrial, Agricultural and Food Process and Systems Engineering, University of Antananarivo, Antananarivo; Higher Institute of Technology and the Environment, University of Fianarantsoa, Fianarantsoa; Laboratory for the Valorization of Natural Resources, Polytechnic High School of Antananarivo, University of Antananarivo, Antananarivo, Madagascar
  2. 2Industrial, Agricultural and Food Process and Systems Engineering, University of Antananarivo, Antananarivo; Laboratory for the Valorization of Natural Resources, Polytechnic High School of Antananarivo, University of Antananarivo, Antananarivo, Madagascar
  3. 3Industrial, Agricultural and Food Process and Systems Engineering, University of Antananarivo, Antananarivo; Geochemistry and Medicinal Chemistry, University of Fianarantsoa, Fianarantsoa, Madagascar
  4. 4Higher Institute of Technology and the Environment, University of Fianarantsoa, Fianarantsoa; Geochemistry and Medicinal Chemistry, University of Fianarantsoa, Fianarantsoa, Madagascar

Abstract

L'accès universel à une eau salubre en milieu rural tropical constitue un défi majeur de santé publique, particulièrement dans les régions de socle cristallin telles que le district d'Isandra à Madagascar. Face aux limites des évaluations normatives unilatérales, cette étude propose une approche méthodologique novatrice articulant des analyses analytiques de pointe et des outils décisionnels avancés. En couplant la spectroscopie de fluorescence X à réflexion totale (TXRF) et l'indice de qualité de l'eau fondé sur la logique floue (FWQI), la recherche évalue la vulnérabilité hydrochimique et microbiologique de quinze stations hydrologiques. Les résultats mettent en évidence des dépassements critiques des seuils de potabilité, notamment des teneurs en fer dissous atteignant 5,38 mg/L et des concentrations de plomb toxique s'élevant jusqu'à 0,053 mg/L. De surcroît, 46,67 % des captages présentent une contamination fécale active. La modélisation par logique floue révèle que 60 % des ouvrages subissent un risque sanitaire marqué et 13,33 % un danger critique. Ce couplage méthodologique s'avère un instrument d'aide à la décision indispensable pour optimiser la gouvernance des ressources hydriques et cibler les interventions d'urgence sanitaire.

Related

  1. Préserver la santé mentale en vieillissant. Modélisation d’un programme probant de santé mentale pour les personnes âgées vivant à domicile
    Gwladys Acoulon, Zékya Ulmer, Iouri Bernache-Assollant +2
    Santé PubliquePeer-reviewedLicence not statedFull text1 citedEpidemiology & public healthHAL
  2. Low rifampicin and early signs of next-line drug resistances: findings from Madagascar’s 2023–24 nationwide drug resistance survey
    Rila Ratovoson, Astrid M. Knoblauch, Simon Grandjean Lapierre +14
    Scientific ReportsPeer-reviewedCC BY 4.0Full textInfectious diseaseCrossref
  3. Small dried fish as an affordable source of key micronutrients in Madagascar: nutritional benefits and contamination risks
    L. D. Todimazava, M. J. Darias, C. Mouquet-Rivier +2
    medRxivPreprintCC BYFull textNutritionmedRxiv
  4. Voices from the front line: Community health workers’ perspectives on effectiveness and needs in Madagascar’s tuberculosis response
    Onja Gabrielle Ravololohanitra, Alphonsine Razanamiarana, Michel Tiaray Harison +6
    PLOS Global Public HealthPeer-reviewedCC BYFull textEpidemiology & public healthInfectious diseasePLOSEurope PMC
  5. Spatial modeling of risk factors for human exposure to West Nile virus in rural Madagascar
    M. Randriamihaja, L. T. Rasoloharimanana, S. Veeragandham +16
    medRxivPreprintCC BYFull textEpidemiology & public healthmedRxiv
BibTeX
@article{rasolondraibe2026évaluation,
  title = {{Évaluation intégrée de la qualité physico-chimique et microbiologique des eaux du district d'Isandra (Madagascar) par couplage de la txrf et de la modélisation par logique floue}},
  author = {Hobilalaina Onimamy RASOLONDRAIBE and Joharisoa Fifaliana RASOLOFOSON and Zafimamonjy Louis Odon FETISONDRAIBE and Boniface Erménégilde RALAIBIA and Emma Voahanginirina RAMANAMPISOA and Daniel Andriamanjato RAZAFINDRAZANAKOLONA and Baholy ROBIJAONA RAHELIVOLOLONIAINA},
  journal = {Revue des Sciences de la Santé},
  year = {2026},
  month = aug,
  doi = {10.71004/rss.026.v5.i2.165},
  url = {https://doi.org/10.71004/rss.026.v5.i2.165},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Évaluation intégrée de la qualité physico-chimique et microbiologique des eaux du district d'Isandra (Madagascar) par couplage de la txrf et de la modélisation par logique floue
AU  - Hobilalaina Onimamy RASOLONDRAIBE
AU  - Joharisoa Fifaliana RASOLOFOSON
AU  - Zafimamonjy Louis Odon FETISONDRAIBE
AU  - Boniface Erménégilde RALAIBIA
AU  - Emma Voahanginirina RAMANAMPISOA
AU  - Daniel Andriamanjato RAZAFINDRAZANAKOLONA
AU  - Baholy ROBIJAONA RAHELIVOLOLONIAINA
PY  - 2026
DA  - 2026/08/01
JO  - Revue des Sciences de la Santé
DO  - 10.71004/rss.026.v5.i2.165
UR  - https://doi.org/10.71004/rss.026.v5.i2.165
AB  - L'accès universel à une eau salubre en milieu rural tropical constitue un défi majeur de santé publique, particulièrement dans les régions de socle cristallin telles que le district d'Isandra à Madagascar. Face aux limites des évaluations normatives unilatérales, cette étude propose une approche méthodologique novatrice articulant des analyses analytiques de pointe et des outils décisionnels avancés. En couplant la spectroscopie de fluorescence X à réflexion totale (TXRF) et l'indice de qualité de l'eau fondé sur la logique floue (FWQI), la recherche évalue la vulnérabilité hydrochimique et microbiologique de quinze stations hydrologiques. Les résultats mettent en évidence des dépassements critiques des seuils de potabilité, notamment des teneurs en fer dissous atteignant 5,38 mg/L et des concentrations de plomb toxique s'élevant jusqu'à 0,053 mg/L. De surcroît, 46,67 % des captages présentent une contamination fécale active. La modélisation par logique floue révèle que 60 % des ouvrages subissent un risque sanitaire marqué et 13,33 % un danger critique. Ce couplage méthodologique s'avère un instrument d'aide à la décision indispensable pour optimiser la gouvernance des ressources hydriques et cibler les interventions d'urgence sanitaire.
SN  - 3078-6959
SN  - 3078-8226
ER  -