Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BYJournal of imaging

Ultrasound vs. MRI Assessment of Rotator Cuff Tear Severity: A Systematic Review and Meta-Analysis of Supraspinatus Tears.

  1. 1Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB T6G 2B7, Canada.

Abstract

Rotator cuff tears involving the supraspinatus tendon are a common cause of shoulder pain. Ultrasound (US) is accessible, dynamic, and less costly than MRI, but its diagnostic performance may vary with tear severity and operator expertise. This systematic review and meta-analysis evaluated the diagnostic performance of US for supraspinatus tears using MRI as the non-invasive reference imaging standard. MEDLINE, Embase, Scopus, and CINAHL Plus were searched for studies published from January 2015 to June 2026, and study quality was assessed using QUADAS-2. A total of 23 studies involving 1452 participants were included. Mean sensitivity, specificity, and accuracy were 89.7%, 97.3%, and 95.4%, respectively, for full-thickness tears, compared with 71.6%, 93.1%, and 80.2% for partial-thickness tears. HSROC analysis excluding studies with high overall risk of bias showed pooled sensitivity and specificity of 83% and 88% for any tear, 67% and 91% for partial-thickness tears, and 72% and 97% for full-thickness tears. Agreement was generally more consistent for full-thickness tears, while operator expertise and study quality varied. Overall, US demonstrated stronger diagnostic performance for full-thickness than partial-thickness supraspinatus tears and may be considered an accessible initial imaging option in appropriate clinical settings, with MRI remaining complementary for equivocal or subtle partial-thickness tears and preoperative assessment.

Related

  1. Application of musculoskeletal ultrasound in postoperative rehabilitation assessment and monitoring after rotator cuff repair: A systematic review
    Ying Shi, Yi Bao, Chuanxiong Li
    PLOS OnePeer-reviewedCC BY 4.0Full textClinical trials & evidence synthesisMedical imaging & radiologyPLOS
  2. Ultrasound Assessment of the Coracohumeral Ligament and Rotator Interval and Its Association With Physical Function in Patients With Adhesive Capsulitis of the Shoulder: A Scoping Review.
    Takato Itou, Hikaru Funayose, Yuichi Isaji
    CureusPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Double Row Side-to-Side Rotator Cuff Repair With Tensionable Knotless Anchors for Traumatic Transtendinous Supraspinatus Tears.
    Michael S Rocca, Camila Grandberg, Sophia I McMahon +4
    Video journal of sports medicinePeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  4. Effects of Extracorporeal Shock Wave Therapy, Photobiomodulation, Ultrasound, and Electrotherapy Modalities on Rotator Cuff-Related Shoulder Pain: A Systematic Review.
    Dennis Bühl, Alexandra Unger, Andreas Konrad
    Journal of functional morphology and kinesiologyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Can Deltoid Hounsfield Unit/Supraspinatus Hounsfield Unit Predict Postoperative Rotator Cuff Retear?
    Xieyu Wang, Guihu Liu, Xiaolong Wang +3
    Orthopaedic surgeryPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{kassam2026ultrasound,
  title = {{Ultrasound vs. MRI Assessment of Rotator Cuff Tear Severity: A Systematic Review and Meta-Analysis of Supraspinatus Tears.}},
  author = {Kareena Kassam and Shrimanti Ghosh and Stephanie Wichuk and Tina Qian and Jessica Knight and Cassandra Gallant and Steel McDonald and Jacob L Jaremko and Abhilash R Hareendranathan},
  journal = {Journal of imaging},
  year = {2026},
  month = nov,
  doi = {10.3390/jimaging12110586},
  url = {https://europepmc.org/article/MED/43082976},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Ultrasound vs. MRI Assessment of Rotator Cuff Tear Severity: A Systematic Review and Meta-Analysis of Supraspinatus Tears.
AU  - Kareena Kassam
AU  - Shrimanti Ghosh
AU  - Stephanie Wichuk
AU  - Tina Qian
AU  - Jessica Knight
AU  - Cassandra Gallant
AU  - Steel McDonald
AU  - Jacob L Jaremko
AU  - Abhilash R Hareendranathan
PY  - 2026
DA  - 2026/11/19
JO  - Journal of imaging
DO  - 10.3390/jimaging12110586
UR  - https://europepmc.org/article/MED/43082976
AB  - Rotator cuff tears involving the supraspinatus tendon are a common cause of shoulder pain. Ultrasound (US) is accessible, dynamic, and less costly than MRI, but its diagnostic performance may vary with tear severity and operator expertise. This systematic review and meta-analysis evaluated the diagnostic performance of US for supraspinatus tears using MRI as the non-invasive reference imaging standard. MEDLINE, Embase, Scopus, and CINAHL Plus were searched for studies published from January 2015 to June 2026, and study quality was assessed using QUADAS-2. A total of 23 studies involving 1452 participants were included. Mean sensitivity, specificity, and accuracy were 89.7%, 97.3%, and 95.4%, respectively, for full-thickness tears, compared with 71.6%, 93.1%, and 80.2% for partial-thickness tears. HSROC analysis excluding studies with high overall risk of bias showed pooled sensitivity and specificity of 83% and 88% for any tear, 67% and 91% for partial-thickness tears, and 72% and 97% for full-thickness tears. Agreement was generally more consistent for full-thickness tears, while operator expertise and study quality varied. Overall, US demonstrated stronger diagnostic performance for full-thickness than partial-thickness supraspinatus tears and may be considered an accessible initial imaging option in appropriate clinical settings, with MRI remaining complementary for equivocal or subtle partial-thickness tears and preoperative assessment.
SN  - 2313-433X
ER  -