Skip to content
DraconiticResearch
Search Sources API
197,783 studies31 sourcesUpdated 7 min ago
PreprintarXiv licencearXiv

The Fluid Mechanics of Truncus Arteriosus

Abstract

Truncus arteriosus (TA) is a rare, severe congenital heart disease in which the two main arteries exiting the heart fail to separate in utero resulting in one truncus and truncal valve, carrying mixed oxygenated and deoxygenated blood. About 25% of patients have a quadricuspid valve, which is prone to regurgitation and re-intervention. Despite its relevance for valve performance and mixing, fluid mechanics in TA are poorly understood. Patient-specific fluid-structure interaction simulations were performed based on CT imaging before and after TA repair. The quadricuspid valve was constructed using elasticity-based design with the patient's free edge length and geometric height extracted from echocardiography. Interaction between blood and valve was simulated with the Immersed Boundary Method. Boundary conditions were tuned to the patient's data. Mixing of oxygenated and deoxygenated blood and streaming were assessed via Lagrangian Coherent Structures (LCS) and Lagrangian Particle Tracing (LPT). Low pressures, forward flow and streamwise vortices in the one-sided pulmonary arteries (PAs) throughout the cardiac cycle affected leaflet motion, leading to asymmetric closure and regurgitation. Holodiastolic aortic flow reversal supplied PA flow and the regurgitant jet. LCS and LPT indicated favorable streaming of oxygenated blood from the LV to the aorta and deoxygenated blood from the RV to the PAs. After truncal surgery, normal hemodynamics were restored. This is the first study of fluid mechanics of TA. Using qualitative and quantitative flow analysis, we identified disrupted preoperative hemodynamics caused by one-sided PAs and showed how normal hemodynamics were re-established after repair. Favorable streaming was demonstrated aligned with patient reports. Thus, favorable streaming is plausible in total mixing lesions and patient-specific modeling may aid in its detection.

Related

  1. Mapping Spatially Heterogeneous and History-Dependent Hydrogel Mechanics Using Fluid-Driven Cyclic Shear
    Pragya Kushwaha, Xuxiang Qian, Sangwoo Shin +1
    ChemRxivPreprintCC BYFull textGeneral medicineChemRxiv
  2. Absent right pulmonary artery with patent ductus arteriosus and Eisenmenger syndrome
    European heart journal. Imaging methods and practicePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Fetal closure of ductus arteriosus in monochorionic diamniotic twins
    Maciej Ziebakowski, Oskar Sylwestrzak, Lukasz Sokolowski +2
    Ginekologia PolskaPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyDOAJ
  4. Anomalous Origin of the Right Pulmonary Artery from the Ascending Aorta in an Adult After Prior Patent Ductus Arteriosus Surgery
    Dan Li, Shuo Liang, Hong Zhang
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Associations Between Longitudinal Antenatal Hematological Indicators and Risk of Patent Ductus Arteriosus in Newborns — Beijing, China, 2011–2025
    Xiaoqian Jia, Pengbo Yuan, Jufen Liu +3
    China CDC weeklyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@misc{bornemann2026fluid,
  title = {{The Fluid Mechanics of Truncus Arteriosus}},
  author = {Karoline-Marie Bornemann and Perry S. Choi and Jay A. Huber and Hannah L. McMullen and Alexander K. Reed and Amit Sharir and Shiraz A. Maskatia and Alison L. Marsden and Michael R. Ma and Alexander D. Kaiser},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.36470},
  eprint = {2609.36470},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.36470},
}
RIS
TY  - UNPB
TI  - The Fluid Mechanics of Truncus Arteriosus
AU  - Karoline-Marie Bornemann
AU  - Perry S. Choi
AU  - Jay A. Huber
AU  - Hannah L. McMullen
AU  - Alexander K. Reed
AU  - Amit Sharir
AU  - Shiraz A. Maskatia
AU  - Alison L. Marsden
AU  - Michael R. Ma
AU  - Alexander D. Kaiser
PY  - 2026
DA  - 2026/09/29
PB  - arXiv
DO  - 10.48550/arxiv.2609.36470
UR  - https://arxiv.org/abs/2609.36470
AB  - Truncus arteriosus (TA) is a rare, severe congenital heart disease in which the two main arteries exiting the heart fail to separate in utero resulting in one truncus and truncal valve, carrying mixed oxygenated and deoxygenated blood. About 25% of patients have a quadricuspid valve, which is prone to regurgitation and re-intervention. Despite its relevance for valve performance and mixing, fluid mechanics in TA are poorly understood. Patient-specific fluid-structure interaction simulations were performed based on CT imaging before and after TA repair. The quadricuspid valve was constructed using elasticity-based design with the patient's free edge length and geometric height extracted from echocardiography. Interaction between blood and valve was simulated with the Immersed Boundary Method. Boundary conditions were tuned to the patient's data. Mixing of oxygenated and deoxygenated blood and streaming were assessed via Lagrangian Coherent Structures (LCS) and Lagrangian Particle Tracing (LPT). Low pressures, forward flow and streamwise vortices in the one-sided pulmonary arteries (PAs) throughout the cardiac cycle affected leaflet motion, leading to asymmetric closure and regurgitation. Holodiastolic aortic flow reversal supplied PA flow and the regurgitant jet. LCS and LPT indicated favorable streaming of oxygenated blood from the LV to the aorta and deoxygenated blood from the RV to the PAs. After truncal surgery, normal hemodynamics were restored. This is the first study of fluid mechanics of TA. Using qualitative and quantitative flow analysis, we identified disrupted preoperative hemodynamics caused by one-sided PAs and showed how normal hemodynamics were re-established after repair. Favorable streaming was demonstrated aligned with patient reports. Thus, favorable streaming is plausible in total mixing lesions and patient-specific modeling may aid in its detection.
ER  -