Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY 4.0PLOS One

Microclimatic regulation effects of landscape elements on university campus in a temperate monsoon climate zone: A case study during extreme summer heat

  1. 1Forestry College, Shenyang Agricultural University, Shenyang, China
  2. 2Key Laboratory of Northern Landscape Plants and Regional Landscape, Shenyang, China

Abstract

Although temperate monsoon climate regions are traditionally known for their harsh winter climates, the combined effects of rapid urbanization and global climate change have significantly intensified summer urban heat island effects in these areas, making them a neglected yet increasingly severe challenge in high-latitude urban climate adaptation planning. This study takes a typical campus in Shenyang, a temperate monsoon climate region in Northeast China, as the experimental subject. It quantitatively dissects the non-linear statistical associations and regulatory mechanisms of biotic and abiotic landscape elements and their spatial configurations on microclimate parameters and human thermal comfort (Physiologically Equivalent Temperature, PET) by combining microclimate field observations with validated ENVI-met numerical simulations. Field measurement results show that the vertical structural characteristics of vegetation dominate cooling efficiency: evergreen trees and shrubs, with their dense radiation-blocking structures, exhibit optimal regulatory potential, with mean Physiological Equivalent Temperature (ΔPET) values reaching 10.6°C and 10.4°C, respectively, significantly outperforming deciduous trees (8.1°C). In contrast, abiotic elements play an auxiliary role, with dynamic water bodies and enclosed pavilions providing PET improvement values of 3.1°C and 2.9°C, respectively, while paving materials have limited direct regulatory capacity (< 2.0°C). Simulation optimization further reveals a significant “blue-green synergy” effect: the composite configuration of high-canopy evergreen trees and large-area dynamic water bodies forms the optimal spatial solution, reducing daily average PET to 48.7°C, a decrease of 7.3°C compared to the vegetation-free baseline scenario. Addressing the unique “humid-heat” challenge that distinguishes temperate monsoon climates from arid or semi-arid regions where summer thermal stress is often attributed solely to high temperatures, this study goes beyond merely documenting cooling effects to elucidate the “structural-thermal decoupling” mechanism in temperate monsoon climates. It challenges the conventional “deciduous-first” design paradigm by quantifying the superior radiative-blocking efficiency of evergreen species during extreme heatwaves, providing a physically-grounded framework for campus microclimate resilience.

Related

  1. Habitat and landscape outweigh stand age as drivers of species composition in managed temperate forests dominated by Quercus robur L. and Quercus petraea (Matt.) Liebl
    Natalia Mazurek, Ewa Stefańska-Krzaczek, Zygmunt Kącki
    Annals of Forest SciencePeer-reviewedCC BY 4.0Full textEcologyHAL
  2. Single-base mapping of m6A in lncRNAs reveals a distinct landscape linked to transposable elements and RNA processing
    E. Kwon, Z. Li, C. Zhou
    bioRxivPreprintCC BY-NC-NDFull textGenetics & genomicsbioRxiv
  3. Soils from different landscape elements diverge in response to multiple global change factors
    T. Hu, M. Bi, M. C. Rillig
    bioRxivPreprintCC BY-NCFull textEcologybioRxiv
  4. Transposable elements impact the human regulatory landscape through cell type specific epigenomic associations
    Jeffrey Hyacinthe, Guillaume Bourque
    Nature CommunicationsPeer-reviewedCC BY-NC-NDFull text9 citedGenetics & genomicsPlant biologyOpenAlex
  5. Avian Diversity and Community Structure in Magadh University Campus Landscape, Bodh Gaya
    M. Kumari, P. P. Das, K. Aditi
    bioRxivPreprintCC BYFull textZoology & animal behaviourbioRxiv
BibTeX
@article{fan2026microclimatic,
  title = {{Microclimatic regulation effects of landscape elements on university campus in a temperate monsoon climate zone: A case study during extreme summer heat}},
  author = {Lei Fan and Yixin Liang and Zixian Li and Yan Zhou},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0362099},
  url = {https://doi.org/10.1371/journal.pone.0362099},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Microclimatic regulation effects of landscape elements on university campus in a temperate monsoon climate zone: A case study during extreme summer heat
AU  - Lei Fan
AU  - Yixin Liang
AU  - Zixian Li
AU  - Yan Zhou
PY  - 2026
DA  - 2026/11/05
JO  - PLOS One
DO  - 10.1371/journal.pone.0362099
UR  - https://doi.org/10.1371/journal.pone.0362099
AB  - Although temperate monsoon climate regions are traditionally known for their harsh winter climates, the combined effects of rapid urbanization and global climate change have significantly intensified summer urban heat island effects in these areas, making them a neglected yet increasingly severe challenge in high-latitude urban climate adaptation planning. This study takes a typical campus in Shenyang, a temperate monsoon climate region in Northeast China, as the experimental subject. It quantitatively dissects the non-linear statistical associations and regulatory mechanisms of biotic and abiotic landscape elements and their spatial configurations on microclimate parameters and human thermal comfort (Physiologically Equivalent Temperature, PET) by combining microclimate field observations with validated ENVI-met numerical simulations. Field measurement results show that the vertical structural characteristics of vegetation dominate cooling efficiency: evergreen trees and shrubs, with their dense radiation-blocking structures, exhibit optimal regulatory potential, with mean Physiological Equivalent Temperature (ΔPET) values reaching 10.6°C and 10.4°C, respectively, significantly outperforming deciduous trees (8.1°C). In contrast, abiotic elements play an auxiliary role, with dynamic water bodies and enclosed pavilions providing PET improvement values of 3.1°C and 2.9°C, respectively, while paving materials have limited direct regulatory capacity (< 2.0°C). Simulation optimization further reveals a significant “blue-green synergy” effect: the composite configuration of high-canopy evergreen trees and large-area dynamic water bodies forms the optimal spatial solution, reducing daily average PET to 48.7°C, a decrease of 7.3°C compared to the vegetation-free baseline scenario. Addressing the unique “humid-heat” challenge that distinguishes temperate monsoon climates from arid or semi-arid regions where summer thermal stress is often attributed solely to high temperatures, this study goes beyond merely documenting cooling effects to elucidate the “structural-thermal decoupling” mechanism in temperate monsoon climates. It challenges the conventional “deciduous-first” design paradigm by quantifying the superior radiative-blocking efficiency of evergreen species during extreme heatwaves, providing a physically-grounded framework for campus microclimate resilience.
SN  - 1932-6203
ER  -