Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part I: General Cases
5 affiliations
- 1Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA; (M.M.R.); (M.H.)
- 2Sentara Health Research Center, Virginia Beach, VA 23464, USA
- 3Department of Medicine, Division of Cardiology, Macon and Joan Brock Virginia Health Sciences at Old Dominion University, Norfolk, VA 23501, USA; (J.M.H.); (L.J.R.)
- 4Advanced Heart Failure and Heart Transplantation, Sentara Norfolk General Hospital, Norfolk, VA 23507, USA
- 5School of Exercise Science, Old Dominion University, Norfolk, VA 23529, USA
Abstract
Background/Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart diseases. Method: Arterial pulse signals at the radial artery (RA) and carotid artery (CA) of each patient were successfully recorded from all 18 patients using micro-fabricated tactile sensors. Signal quality was screened before analysis, and the accepted signals were analyzed using a single-degree-of-freedom time–frequency (SDOF-TF) framework. Key CV parameters, including time-based indices—heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM), as well as harmonic amplitudes and normalized arterial pulse waveform (APW)—were extracted from measurements at rest and post-exercise across three rehabilitation visits in 18 patients with heterogeneous CV conditions. Longitudinal changes in CV parameters within subjects and variability between subjects were assessed. Results: Compared with a healthy reference, the patients exhibited heterogeneous CV profiles, with lower HRV in all patients except one with AF, who showed elevated HRV, and generally reduced post-exercise CV responses. Higher-order harmonic amplitudes were attenuated at the RA, while CA-derived APW measurements showed greater sensitivity to systolic upstroke slope. Marked inter-subject variability was evident in at-rest CV parameters and 5-min post-exercise responses. Longitudinal CV responses varied across rehabilitation visits, potentially reflecting multiple contributing factors. Conclusions: The 100% pulse acquisition rate supports the feasibility of the tactile sensor technology for pulse measurement, and the combined sensor technology and SDOF-TF framework enable quantitative characterization of shared and individualized CV patterns in cardiac patients and their post-exercise recovery, including time-based indices, harmonic signatures, site-specific differences, and interactions among CV parameters. These findings warrant further investigation in larger cohorts with appropriate physiological reference measurements.
Related
- Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part II: Special Cases
- Epimeric Vitamin D is Not Associated With Arterial Stiffness or Cardiovascular Outcomes in Patients With Advanced CKD.
- Risk Factors and Subtype-Specific Prediction Models for Arterial versus Venous Thrombotic Events in Chinese Patients with Lupus Nephritis: A Retrospective Cohort Study
- Sex- and Menopause-Specific Hormone-Related ECG Signatures and Incident Cardiovascular Risk in UK Biobank
- Hospitalized patients lack pathogen-specific comorbidity signatures: general vulnerability and case fatality drive differences in mortality
BibTeX
@article{rahman2026subjectspecific,
title = {{Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part I: General Cases}},
author = {Md Mahfuzur Rahman and Mamun Hasan and Jennifer F. May and John M. Herre and Leryn J. Reynolds and Zhili Hao},
journal = {Diagnostics},
year = {2026},
month = oct,
doi = {10.3390/diagnostics16213579},
url = {https://doi.org/10.3390/diagnostics16213579},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part I: General Cases
AU - Md Mahfuzur Rahman
AU - Mamun Hasan
AU - Jennifer F. May
AU - John M. Herre
AU - Leryn J. Reynolds
AU - Zhili Hao
PY - 2026
DA - 2026/10/29
JO - Diagnostics
DO - 10.3390/diagnostics16213579
UR - https://doi.org/10.3390/diagnostics16213579
AB - Background/Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart diseases. Method: Arterial pulse signals at the radial artery (RA) and carotid artery (CA) of each patient were successfully recorded from all 18 patients using micro-fabricated tactile sensors. Signal quality was screened before analysis, and the accepted signals were analyzed using a single-degree-of-freedom time–frequency (SDOF-TF) framework. Key CV parameters, including time-based indices—heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM), as well as harmonic amplitudes and normalized arterial pulse waveform (APW)—were extracted from measurements at rest and post-exercise across three rehabilitation visits in 18 patients with heterogeneous CV conditions. Longitudinal changes in CV parameters within subjects and variability between subjects were assessed. Results: Compared with a healthy reference, the patients exhibited heterogeneous CV profiles, with lower HRV in all patients except one with AF, who showed elevated HRV, and generally reduced post-exercise CV responses. Higher-order harmonic amplitudes were attenuated at the RA, while CA-derived APW measurements showed greater sensitivity to systolic upstroke slope. Marked inter-subject variability was evident in at-rest CV parameters and 5-min post-exercise responses. Longitudinal CV responses varied across rehabilitation visits, potentially reflecting multiple contributing factors. Conclusions: The 100% pulse acquisition rate supports the feasibility of the tactile sensor technology for pulse measurement, and the combined sensor technology and SDOF-TF framework enable quantitative characterization of shared and individualized CV patterns in cardiac patients and their post-exercise recovery, including time-based indices, harmonic signatures, site-specific differences, and interactions among CV parameters. These findings warrant further investigation in larger cohorts with appropriate physiological reference measurements.
SN - 2075-4418
ER -