Longitudinal changes in bleb morphology following the PAUL Glaucoma Implant visualized using ultrasonography
- 1Department of Ophthalmology University of Bonn Bonn Germany
- 2Department of Ophthalmology, Klinikum Dortmund University Witten/Herdecke Dortmund Germany
- 3Institute for Medical Biometry, Informatics and Epidemiology University of Bonn Bonn Germany
Abstract
Purpose: To evaluate bleb morphology longitudinally using sonography following glaucoma drainage device (GDD) surgery.
Methods: Prospective observational cohort study conducted from January 2022 to March 2024, with follow‐up up to 12 months postoperatively. Bleb morphology, including superior and inferior bleb height, transverse and longitudinal dimensions, and total bleb height, was assessed using 15‐MHz ultrasound (Quantel Medical, Compact Touch).
Results: Forty‐eight eyes undergoing PGI implantation were prospectively enrolled. Preoperative mean IOP was 23.6 mmHg (range, 13–42) on 3.2 medications. Mean total bleb height increased from 2.33 mm (range, 0.64–6.6) at day 14 to 4.14 mm (1.21–7.66) at month 3 and remained stable through month 12 (4.21 mm; 2.13–9.4). Double‐layered blebs predominated by month 1 and persisted thereafter. Mean IOP decreased to 12.7 mmHg at day 14 and remained between 13 and 15 mmHg through 12 months, while medication use declined to 0.9 drops. Mixed‐model analysis showed that absolute bleb height was significantly associated with higher IOP (β = 0.86, p = 0.043), independent of time. Accelerated bleb enlargement within the first 3 months correlated with higher IOP (β = 3.57, p = 0.003), whereas later changes showed no consistent associations.
Conclusions: Ultrasound imaging revealed progressive bleb enlargement after PGI implantation, stabilizing by 3–6 months. In the subgroup of patients who completed the 12‐month follow‐up, IOP reduction remained stable throughout the first postoperative year. Absolute bleb height showed a consistent association with IOP across time, whereas early growth rate was only predictive during the early postoperative period. These findings provide the first longitudinal sonographic evidence of bleb remodelling after GDD surgery and may guide postoperative assessment and intervention timing.
Related
- Baricitinib Attenuates Dermal and Pulmonary Fibrosis in a Bleomycin-Induced Murine Scleroderma Model: A Longitudinal High-Frequency Ultrasonography Study
- Surgical management of bilateral corneoconjunctival dermoids in a calf using conjunctival flap reconstruction following perioperative ocular ultrasonography
- Multifocal Posterior Pigment Epitheliopathy in a Pachychoroid Eye Following Ahmed Glaucoma Valve Implantation: A Case Report
- Case Report: Successful needle revision of an encapsulated bleb following PAUL glaucoma Implant surgery in a pediatric patient
- Endophthalmitis following glaucoma drainage device surgery
BibTeX
@article{liegl2026longitudinal,
title = {{Longitudinal changes in bleb morphology following the PAUL Glaucoma Implant visualized using ultrasonography}},
author = {Constance Liegl and Benjamin Aretz and Leonie Bourauel and Pascal Schipper and Carolin Deubel and Lilli Joussen and Michael Petrak and Frank G. Holz and Raffael Liegl and Karl Mercieca},
journal = {Acta Ophthalmologica},
year = {2026},
month = jul,
doi = {10.1111/aos.70180},
url = {https://doi.org/10.1111/aos.70180},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Longitudinal changes in bleb morphology following the PAUL Glaucoma Implant visualized using ultrasonography
AU - Constance Liegl
AU - Benjamin Aretz
AU - Leonie Bourauel
AU - Pascal Schipper
AU - Carolin Deubel
AU - Lilli Joussen
AU - Michael Petrak
AU - Frank G. Holz
AU - Raffael Liegl
AU - Karl Mercieca
PY - 2026
DA - 2026/07/22
JO - Acta Ophthalmologica
DO - 10.1111/aos.70180
UR - https://doi.org/10.1111/aos.70180
AB - Purpose: To evaluate bleb morphology longitudinally using sonography following glaucoma drainage device (GDD) surgery. Methods: Prospective observational cohort study conducted from January 2022 to March 2024, with follow‐up up to 12 months postoperatively. Bleb morphology, including superior and inferior bleb height, transverse and longitudinal dimensions, and total bleb height, was assessed using 15‐MHz ultrasound (Quantel Medical, Compact Touch). Results: Forty‐eight eyes undergoing PGI implantation were prospectively enrolled. Preoperative mean IOP was 23.6 mmHg (range, 13–42) on 3.2 medications. Mean total bleb height increased from 2.33 mm (range, 0.64–6.6) at day 14 to 4.14 mm (1.21–7.66) at month 3 and remained stable through month 12 (4.21 mm; 2.13–9.4). Double‐layered blebs predominated by month 1 and persisted thereafter. Mean IOP decreased to 12.7 mmHg at day 14 and remained between 13 and 15 mmHg through 12 months, while medication use declined to 0.9 drops. Mixed‐model analysis showed that absolute bleb height was significantly associated with higher IOP (β = 0.86, p = 0.043), independent of time. Accelerated bleb enlargement within the first 3 months correlated with higher IOP (β = 3.57, p = 0.003), whereas later changes showed no consistent associations. Conclusions: Ultrasound imaging revealed progressive bleb enlargement after PGI implantation, stabilizing by 3–6 months. In the subgroup of patients who completed the 12‐month follow‐up, IOP reduction remained stable throughout the first postoperative year. Absolute bleb height showed a consistent association with IOP across time, whereas early growth rate was only predictive during the early postoperative period. These findings provide the first longitudinal sonographic evidence of bleb remodelling after GDD surgery and may guide postoperative assessment and intervention timing.
SN - 1755-375X
SN - 1755-3768
ER -