Persistent peri-device leak following left atrial appendage occlusion treated with hybrid coil- and plug-based closure: a case report.
- 1Department of Cardiology, Odense University Hospital, J.B. Winsløwsvej 4, Odense C 5000, Denmark.
Abstract
Background
Left atrial appendage occlusion (LAAO) is an emerging alternative to long-term anticoagulation in patients with atrial fibrillation, but peri-device leaks remain a clinical challenge.Case summary
A 63-year-old man with permanent atrial fibrillation, heart failure, a prior ischaemic stroke history was referred for LAAO due to recurrent anticoagulation-related bleeding. Pre-procedural computer tomography (CT) showed a markedly enlarged appendage suitable for a 35-mm WATCHMAN FLX, which was implanted under intracardiac echocardiography guidance, with subsequent transition to aspirin. Three months later, CT revealed a tilted device with a peri-skirt leak; an ischaemic stroke had occurred in the interim, and anticoagulation was resumed. An Amplatzer Vascular Plug II was implanted but follow-up CT demonstrated persistent contrast passage and more but incomplete occlusion. Three months later, the patient experienced a second stroke, and CT confirmed ongoing peri-device flow. A hybrid leak-closure procedure was performed with coils in the appendage and within the device, followed by a 12-mm plug at the leak channel, achieving near-complete occlusion. At 7-month follow-up, the patient remained on rivaroxaban therapy, briefly interrupted due to haematuria associated with nephrolithiasis.Discussion
Most cases of peri-device leak after LAAO are related to suboptimal device alignment, incomplete endothelialization, or persistent peri-skirt channels. In our case, device tilt with a peri-skirt tract persisted despite initial plug-based closure. This case provides insight into the potential role of hybrid coil- and plug-based strategies in enhancing occlusion but also highlights that anticoagulation remains necessary when full occlusion is not obtained.
Related
- Suture-Mediated Vascular Closure Improves Same-Day Discharge in Atrial Fibrillation Ablation and Left Atrial Appendage Occlusion
- Persistent iatrogenic atrial septal defect after single-puncture, double transseptal access for 4D ICE-guided left atrial appendage occlusion: Incidence and clinical outcomes
- Recurrent Pleuropericardial Effusions Following Amplatzer Amulet Left Atrial Appendage Occlusion: A Case of Post-Cardiac Injury Syndrome
- Concomitant atrial fibrillation ablation and left atrial appendage occlusion: rationale, outcomes, and future directions
- Left Atrial Appendage Occlusion Device Infection: A Rare Case Report and Literature Review
BibTeX
@article{sulaiman2026persistent,
title = {{Persistent peri-device leak following left atrial appendage occlusion treated with hybrid coil- and plug-based closure: a case report.}},
author = {Ardashir Ibrahim Sulaiman and Jens Trøan and Martin Kirk Christensen and Lisette Okkels Jensen and Mikkel Hougaard},
journal = {European heart journal. Case reports},
year = {2026},
month = oct,
doi = {10.1093/ehjcr/ytag817},
url = {https://europepmc.org/article/MED/43011619},
note = {CC BY},
}
RIS
TY - JOUR
TI - Persistent peri-device leak following left atrial appendage occlusion treated with hybrid coil- and plug-based closure: a case report.
AU - Ardashir Ibrahim Sulaiman
AU - Jens Trøan
AU - Martin Kirk Christensen
AU - Lisette Okkels Jensen
AU - Mikkel Hougaard
PY - 2026
DA - 2026/10/31
JO - European heart journal. Case reports
DO - 10.1093/ehjcr/ytag817
UR - https://europepmc.org/article/MED/43011619
AB - Background Left atrial appendage occlusion (LAAO) is an emerging alternative to long-term anticoagulation in patients with atrial fibrillation, but peri-device leaks remain a clinical challenge.Case summary A 63-year-old man with permanent atrial fibrillation, heart failure, a prior ischaemic stroke history was referred for LAAO due to recurrent anticoagulation-related bleeding. Pre-procedural computer tomography (CT) showed a markedly enlarged appendage suitable for a 35-mm WATCHMAN FLX, which was implanted under intracardiac echocardiography guidance, with subsequent transition to aspirin. Three months later, CT revealed a tilted device with a peri-skirt leak; an ischaemic stroke had occurred in the interim, and anticoagulation was resumed. An Amplatzer Vascular Plug II was implanted but follow-up CT demonstrated persistent contrast passage and more but incomplete occlusion. Three months later, the patient experienced a second stroke, and CT confirmed ongoing peri-device flow. A hybrid leak-closure procedure was performed with coils in the appendage and within the device, followed by a 12-mm plug at the leak channel, achieving near-complete occlusion. At 7-month follow-up, the patient remained on rivaroxaban therapy, briefly interrupted due to haematuria associated with nephrolithiasis.Discussion Most cases of peri-device leak after LAAO are related to suboptimal device alignment, incomplete endothelialization, or persistent peri-skirt channels. In our case, device tilt with a peri-skirt tract persisted despite initial plug-based closure. This case provides insight into the potential role of hybrid coil- and plug-based strategies in enhancing occlusion but also highlights that anticoagulation remains necessary when full occlusion is not obtained.
SN - 2514-2119
ER -