Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 42 min ago
PreprintCC BY 4.0arXiv

New muon transfer cell for muonic x-ray spectroscopy on microgram-quantity targets based on liquid hydrogen

Abstract

The muon transfer method allows access to radioactive/rare atomic nuclei for determining their charge radii via muonic x-ray spectroscopy. In this study we present a new muon transfer cell based on liquid hydrogen optimized for low-energy x-ray spectroscopy by employing a thin-walled Mylar cell for the container of the liquid hydrogen. Based on simulations, the present liquid hydrogen cell achieves competitive efficiencies compared to existing devices using the muon transfer method. Additionally, the liquid-hydrogen-based muon transfer setup provides a short timescale for the diffusion process of the muonic hydrogen atoms in the cell, well below 200~ns.

Related

  1. Intracavity Dual-Resonance Stimulated Raman Spectroscopy with Cavity Ringdown Readout for Resolving Hydrogen Rotational Raman Transitions
    Qinxue Nie, Guanda Lyu, Yue Yan +1
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  2. Hydrogen and Lithium Isotope Analysis via Optical Spectroscopy of Laser-Produced Plasmas
    Elizabeth Kautz, Caleb Clark, Nusrat Karim +2
    arXivPreprintCC BY 4.0Full textPlasma physicsarXiv
  3. Raman Spectroscopy Reveals Isotope-specific Hydrogen Bond Kinetics in a Spherical Droplet leading to Preferential Evaporation of D2O in H2O-D2O Mixture
    Sujay Paul, Dinesh Sharma, Arun Chattopadhyay
    ChemRxivPreprintCC BY-NC-NDFull textAtomic, molecular & optical physicsChemRxiv
  4. Water hydrogen bond network elongation below the lower critical solution temperature in aqueous triethylamine solution probed by soft X-ray absorption spectroscopy
    Masanari Nagasaka, Kenji Mochizuki
    ChemRxivPreprintCC BYFull textAtomic, molecular & optical physicsChemRxiv
  5. Automated end-station at the soft X-ray beamline featuring robotic air-to-ultrahigh-vacuum sample transfer, scanning probe spectroscopy, and machine learning analysis
    Keita Hiromori, Masashige Miyamoto, Masafumi Horio +4
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
BibTeX
@misc{enciu2026muon,
  title = {{New muon transfer cell for muonic x-ray spectroscopy on microgram-quantity targets based on liquid hydrogen}},
  author = {M. Enciu and A. Antognini and K. Kirch and A. Knecht and K. Lehrke and J. Völkert and Y. Zhuang},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.38758},
  eprint = {2610.38758},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.38758},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - New muon transfer cell for muonic x-ray spectroscopy on microgram-quantity targets based on liquid hydrogen
AU  - M. Enciu
AU  - A. Antognini
AU  - K. Kirch
AU  - A. Knecht
AU  - K. Lehrke
AU  - J. Völkert
AU  - Y. Zhuang
PY  - 2026
DA  - 2026/10/28
PB  - arXiv
DO  - 10.48550/arxiv.2610.38758
UR  - https://arxiv.org/abs/2610.38758
AB  - The muon transfer method allows access to radioactive/rare atomic nuclei for determining their charge radii via muonic x-ray spectroscopy. In this study we present a new muon transfer cell based on liquid hydrogen optimized for low-energy x-ray spectroscopy by employing a thin-walled Mylar cell for the container of the liquid hydrogen. Based on simulations, the present liquid hydrogen cell achieves competitive efficiencies compared to existing devices using the muon transfer method. Additionally, the liquid-hydrogen-based muon transfer setup provides a short timescale for the diffusion process of the muonic hydrogen atoms in the cell, well below 200~ns.
ER  -