Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 48 min ago
PreprintCC BY 4.0arXiv

Heating of black-Si by microwaves at 2.45 GHz: effect of nano-needle orientation

Abstract

Silicon, which is highly reflective and has negligible absorption at the microwave 2.45 GHz range, can be heated when it is turned into black-Si with a surface texture of nano-needles made by SF6/O2 plasma etching. Microwave heating of flat Si and of black-Si with vertical and with tilted (oriented) nano-needles was compared under identical conditions in a cylindrical TM010 resonator. Samples were placed horizontally on a 150-micrometer-thick cover glass, which standardized their height and position inside the cavity and allowed a common calibration of the radiation thermometer against a K-type thermocouple. Under a stepwise protocol of only 2-3-4 W of microwave power (60 s per step), black-Si with vertical needles reached ~ 260 C, systematically exceeding flat Si (~ 190 C), while black-Si with oriented needles showed a delayed but abrupt onset of heating at 3 W. In situ monitoring of the cavity resonance revealed a 2-3 MHz downshift of the resonance frequency f for all samples, with the drift consistently appearing once the sample temperature exceeded ~ 120 - 150 C, consistent with thermally activated carrier generation in Si. At a given temperature, each sample loads the cavity at a different f and quality factor Q, indicating an orientation-dependent effective permittivity of the nano-needle array, in line with the strong form birefringence of tilted black-Si. Application potential and challenges in the quantitative temperature and permittivity determination are discussed.

Related

  1. Dependence of the acoustic propulsion of nano- and microcones on their orientation and aspect ratio
    Johannes Voß, Raphael Wittkowski
    arXivPreprintarXiv licenceFull textCondensed matterFluid dynamicsarXiv
  2. Orientation-selective microwave heating of laser-graphitized diamond at 2.45 GHz
    Massimiliano Zamengo, Meguya Ryu, Haoran Mu +6
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  3. A dark-matter-sensitive orientation clock near rotating black holes
    Mohsen Fathi
    arXivPreprintCC BY 4.0Full textCosmologyHigh-energy astrophysicsarXiv
  4. Constraining spinning primordial black holes with interstellar dust heating
    Qianyong Li, Yupeng Yang
    arXivPreprintCC BY 4.0Full textCosmologyGravitation & general relativityarXiv
  5. Magnetic Reconnection Heating of Thin Accretion Disks around Kerr Black Holes
    Zhen Li
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsGravitation & general relativityarXiv
BibTeX
@misc{zamengo2026heating,
  title = {{Heating of black-Si by microwaves at 2.45 GHz: effect of nano-needle orientation}},
  author = {Massimiliano Zamengo and Haoran Mu and Hsin-Hui Huang and Tomas Katkus and Darius Gailevičius and Saulius Juodkazis and Junko Morikawa},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.13683},
  eprint = {2609.13683},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.13683},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Heating of black-Si by microwaves at 2.45 GHz: effect of nano-needle orientation
AU  - Massimiliano Zamengo
AU  - Haoran Mu
AU  - Hsin-Hui Huang
AU  - Tomas Katkus
AU  - Darius Gailevičius
AU  - Saulius Juodkazis
AU  - Junko Morikawa
PY  - 2026
DA  - 2026/09/12
PB  - arXiv
DO  - 10.48550/arxiv.2609.13683
UR  - https://arxiv.org/abs/2609.13683
AB  - Silicon, which is highly reflective and has negligible absorption at the microwave 2.45 GHz range, can be heated when it is turned into black-Si with a surface texture of nano-needles made by SF6/O2 plasma etching. Microwave heating of flat Si and of black-Si with vertical and with tilted (oriented) nano-needles was compared under identical conditions in a cylindrical TM010 resonator. Samples were placed horizontally on a 150-micrometer-thick cover glass, which standardized their height and position inside the cavity and allowed a common calibration of the radiation thermometer against a K-type thermocouple. Under a stepwise protocol of only 2-3-4 W of microwave power (60 s per step), black-Si with vertical needles reached ~ 260 C, systematically exceeding flat Si (~ 190 C), while black-Si with oriented needles showed a delayed but abrupt onset of heating at 3 W. In situ monitoring of the cavity resonance revealed a 2-3 MHz downshift of the resonance frequency f for all samples, with the drift consistently appearing once the sample temperature exceeded ~ 120 - 150 C, consistent with thermally activated carrier generation in Si. At a given temperature, each sample loads the cavity at a different f and quality factor Q, indicating an orientation-dependent effective permittivity of the nano-needle array, in line with the strong form birefringence of tilted black-Si. Application potential and challenges in the quantitative temperature and permittivity determination are discussed.
ER  -