Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 5 min ago
Peer-reviewedCC BY-NC-ND 4.0Scientific Reports

Effects of vertebral shortening during corrective osteotomy for spinal deformity on spinal cord biomechanics and cerebrospinal fluid-anterior spinal artery fluid-structure interaction

Abstract

Corrective osteotomy for severe spinal deformity requires vertebral shortening, but the safe degree of shortening remains uncertain. This study used fluid-structure interaction finite element analysis to investigate how graded vertebral shortening affects cerebrospinal fluid (CSF) dynamics and anterior spinal artery (ASA) perfusion. A three-dimensional T1-T12 model was reconstructed from computed tomography data obtained from a 16-year-old male with scoliosis. Posterior vertebral column resection at T8/T9 was simulated in four conditions: no shortening and shortening by one-third, one-half, and two-thirds. Coupled CSF-dura and blood-vessel wall models were used to quantify pressure, wall shear stress, flow velocity, structural stress, and displacement. With shortening of up to one-half, CSF wall shear stress (~ 0.04 Pa) and velocity (~ 0.014 m/s) remained stable, whereas ASA luminal pressure and velocity declined gradually together with vessel-wall stress and displacement, indicating preserved hemodynamic compensation and mechanical unloading. At two-thirds shortening, CSF wall shear stress (0.4998 Pa) and velocity (0.16009 m/s) increased by approximately 12-fold and 11-fold, respectively; dural stress increased by approximately 34%, whereas displacement increased by only 1.2%, demonstrating nonlinear stress-displacement decoupling. ASA luminal pressure, velocity, vessel-wall stress, and displacement also rebounded to their highest values. In this patient-specific model, shortening up to one-half was associated with relative stability of CSF dynamics and progressive vascular unloading, whereas two-thirds shortening produced marked nonlinear changes in CSF and ASA-related biomechanical variables. These findings suggest a model-derived biomechanical transition between one-half and two-thirds shortening; however, this transition should not be interpreted as a clinically validated safety threshold.

Related

  1. Biomechanical study on the interaction between the extent of lumbar vertebral lamina and facet joint removal and segmental stability: a finite element analysis
    Guoqiang Zhang, Xiangyao Sun, Aixing Pan +1
    BMC Musculoskeletal DisordersPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMCEurope PMC
  2. SCOPE (Scapular Corrections for Posterior Escape) for posterior glenohumeral instability: technique of posterior acromial corrective osteotomy with optional glenoid corrective osteotomy
    Jean-David Werthel, Matthias A. Zumstein, Bastian Sigrist +5
    JSES Reviews, Reports, and TechniquesPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMCEurope PMC
  3. Comparison of NASM Corrective Exercise Alone Versus with Kinesio Taping on Navicular Drop and Lower Limb Function in Female Adolescents with Flexible Flatfoot: A Randomized Clinical Trial
    Vahid Mazloum, Ali Honarvar, Seyedeh Sarina Tofighi +1
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  4. Association between prior corrective spinal alignment surgery and post-operative range of motion following reverse total shoulder arthroplasty
    Kazumasa Takayama, MD, Hiromu Ito, MD, PhD
    JSES Reviews, Reports, and TechniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  5. Effectiveness of Plyometric Exercises Versus Flatfoot Corrective Exercises on Balance and Foot Posture in Obese Children with a Flexible Flatfoot: A Comparative Study
    M. Manimala, P. Wajapey
    medRxivPreprintCC0Full textGeneral medicinemedRxiv
BibTeX
@article{yusufu2026effects,
  title = {{Effects of vertebral shortening during corrective osteotomy for spinal deformity on spinal cord biomechanics and cerebrospinal fluid-anterior spinal artery fluid-structure interaction}},
  author = {Alimujiang Yusufu and Abudula Abulaiti and Abuduwupuer Haibier and Yuan Ma},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-71867-7},
  url = {https://www.nature.com/articles/s41598-026-71867-7},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Effects of vertebral shortening during corrective osteotomy for spinal deformity on spinal cord biomechanics and cerebrospinal fluid-anterior spinal artery fluid-structure interaction
AU  - Alimujiang Yusufu
AU  - Abudula Abulaiti
AU  - Abuduwupuer Haibier
AU  - Yuan Ma
PY  - 2026
DA  - 2026/10/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-71867-7
UR  - https://www.nature.com/articles/s41598-026-71867-7
AB  - Corrective osteotomy for severe spinal deformity requires vertebral shortening, but the safe degree of shortening remains uncertain. This study used fluid-structure interaction finite element analysis to investigate how graded vertebral shortening affects cerebrospinal fluid (CSF) dynamics and anterior spinal artery (ASA) perfusion. A three-dimensional T1-T12 model was reconstructed from computed tomography data obtained from a 16-year-old male with scoliosis. Posterior vertebral column resection at T8/T9 was simulated in four conditions: no shortening and shortening by one-third, one-half, and two-thirds. Coupled CSF-dura and blood-vessel wall models were used to quantify pressure, wall shear stress, flow velocity, structural stress, and displacement. With shortening of up to one-half, CSF wall shear stress (~ 0.04 Pa) and velocity (~ 0.014 m/s) remained stable, whereas ASA luminal pressure and velocity declined gradually together with vessel-wall stress and displacement, indicating preserved hemodynamic compensation and mechanical unloading. At two-thirds shortening, CSF wall shear stress (0.4998 Pa) and velocity (0.16009 m/s) increased by approximately 12-fold and 11-fold, respectively; dural stress increased by approximately 34%, whereas displacement increased by only 1.2%, demonstrating nonlinear stress-displacement decoupling. ASA luminal pressure, velocity, vessel-wall stress, and displacement also rebounded to their highest values. In this patient-specific model, shortening up to one-half was associated with relative stability of CSF dynamics and progressive vascular unloading, whereas two-thirds shortening produced marked nonlinear changes in CSF and ASA-related biomechanical variables. These findings suggest a model-derived biomechanical transition between one-half and two-thirds shortening; however, this transition should not be interpreted as a clinically validated safety threshold.
SN  - 2045-2322
ER  -