Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated just now
Peer-reviewedCC BY 4.0ACS Omega

Signal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II

  1. 1Federal University of Santa Maria , , , ,
  2. 2Federal Rural University of Pernambuco , , , ,

Abstract

Water security is a global priority and relies on reliable microbiological monitoring in treated effluents. In this work, we investigate a sensor-analytics component of Escherichia coli (E. coli) monitoring in treated wastewater through fluorescence time courses acquired with a miniaturized, Internet of Things-enabled incubation platform, named the Optical Bacterial Growth Sensor–Fluorescence Detector. The signal arises from hydrolysis of a β-d-glucuronide substrate mediated by E. coli-expressed β-glucuronidase activity, yielding characteristic kinetic profiles over time. Our primary target is the extraction and probabilistic modeling of the upper time-to-detection, TTD+, an operational timing feature of the recorded fluorescence response. In practical terms, TTD+ retrospectively identifies the onset of the upper stable signal region under the adopted criterion, providing a timing summary for assay duration planning. To model this time-domain boundary, we adopt the Joint Censoring and Sensor Model Approach (JCSMA) and further extend it by deriving analytical expressions for ordinary moments and entropy measures, including Rényi and Shannon entropies. The empirical comparison favors JCSMA within the evaluated model set, while simulation characterizes the sampling behavior of selected statistics under the fitted model. The resulting probabilities and quantiles provide summaries for assay duration planning under the adopted conditions. The study does not evaluate analytical figures of merit for E. coli quantification or the association between TTD+ and reference most probable number values.

Related

  1. Dual-band scanned-wavelength infrared laser-induced fluorescence of CO with time-domain modeling for 1 kHz thermometry
    Garrett C. Mathews, Jonathan Rustad, Christopher S. Goldenstein
    Optics ExpressPeer-reviewedPublisher termsFull textPhysical chemistryCrossref
  2. Tuning the fluorescence response of Zn-MOFs through ligand replacement for ultrasensitive metronidazole detection
    Karim Ben Kamel, Noureddine Amdouni, Yves Chevalier +1
    Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy [1994-...]Peer-reviewedPublisher termsFull textInorganic & organometallic chemistryHAL
  3. Selective Hg2+ Detection Using an Aza-BODIPY-Derived NIR Fluorescence Sensor: Environmental and Biological Applications
    Nirawit Kaewnok, Jitnapa Sirirak, Natdhera Sanmanee +3
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textPhysical chemistryCrossrefPMC
  4. Facile smartphone-assisted colorimetric detection of high-load Hg2+ in industrial wastewater using a silica-supported ion-imprinted polymer
    Ly Tan Nhiem, Phan Huynh Tue Nam, Tran Thi Nhung +1
    RSC advancesPeer-reviewedCC BY-NCFull textAnalytical chemistryEurope PMCEurope PMCPMC
  5. Cationic Phenylpyridine Labeling for Improved Oligosaccharide and Glycan Analysis by Capillary Electrophoresis with LED-Induced Fluorescence Detection
    Filip Dusa, Michal Gregus, Richard Cmelik +4
    ACS OmegaPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossref
BibTeX
@article{haab2026signalanalytics,
  title = {{Signal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II}},
  author = {Charles Andre Haab and Jussiane Souza Silva and Thiago Alexandro Nascimento de Andrade and Frank Gomes-Silva and Adriano Marques Jaime and Maíra Casali Malonn and Vandré Sonza Pinto and Darliana Mello Souza and Leandro Michels},
  journal = {ACS Omega},
  year = {2026},
  month = nov,
  doi = {10.1021/acsomega.6c07971},
  url = {https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c07971/5462564/Signal-Analytics-Modeling-of-Fluorescence-Maximum},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Signal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II
AU  - Charles Andre Haab
AU  - Jussiane Souza Silva
AU  - Thiago Alexandro Nascimento de Andrade
AU  - Frank Gomes-Silva
AU  - Adriano Marques Jaime
AU  - Maíra Casali Malonn
AU  - Vandré Sonza Pinto
AU  - Darliana Mello Souza
AU  - Leandro Michels
PY  - 2026
DA  - 2026/11/03
JO  - ACS Omega
DO  - 10.1021/acsomega.6c07971
UR  - https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c07971/5462564/Signal-Analytics-Modeling-of-Fluorescence-Maximum
AB  - Water security is a global priority and relies on reliable microbiological monitoring in treated effluents. In this work, we investigate a sensor-analytics component of Escherichia coli (E. coli) monitoring in treated wastewater through fluorescence time courses acquired with a miniaturized, Internet of Things-enabled incubation platform, named the Optical Bacterial Growth Sensor–Fluorescence Detector. The signal arises from hydrolysis of a β-d-glucuronide substrate mediated by E. coli-expressed β-glucuronidase activity, yielding characteristic kinetic profiles over time. Our primary target is the extraction and probabilistic modeling of the upper time-to-detection, TTD+, an operational timing feature of the recorded fluorescence response. In practical terms, TTD+ retrospectively identifies the onset of the upper stable signal region under the adopted criterion, providing a timing summary for assay duration planning. To model this time-domain boundary, we adopt the Joint Censoring and Sensor Model Approach (JCSMA) and further extend it by deriving analytical expressions for ordinary moments and entropy measures, including Rényi and Shannon entropies. The empirical comparison favors JCSMA within the evaluated model set, while simulation characterizes the sampling behavior of selected statistics under the fitted model. The resulting probabilities and quantiles provide summaries for assay duration planning under the adopted conditions. The study does not evaluate analytical figures of merit for E. coli quantification or the association between TTD+ and reference most probable number values.
SN  - 2470-1343
ER  -