Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 8 min ago
Peer-reviewedCC BYDiagnostics (Basel, Switzerland)

Diagnostic Performance of 99mTc-MAG3 Renal Scintigraphy for Acute Tubular Necrosis and Acute Rejection in Kidney Transplant Recipients with Suspected Graft Dysfunction During the First 90 Days: A Single-Center, Biopsy-Referenced Retrospective Study

5 affiliations
  1. 1Organ Transplantation Unit, Department of Surgery, , Jerusalem 91120, Israel; (S.S.); (M.R.); (A.S.); (O.C.-A.)
  2. 2Department of Radiology, , Jerusalem 91120, Israel; (R.I.); (I.T.)
  3. 3Department of Nephrology, , Jerusalem 91120, Israel; (K.T.); (R.A.)
  4. 4Department of Medical Biophysics and Nuclear Medicine, , Jerusalem 91120, Israel;
  5. 5Department of Surgery, , Jerusalem 91120, Israel;

Related

  1. Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxymethylene Diphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy
    A. Costa, A. Suits, J. Miller +9
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  2. CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study
    Ömer Damar, Mahmut Yaman
    TomographyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  3. Diagnostic performance, implementation fidelity, and costs of the World Health Organization three-test HIV testing strategy in Malawi: a national retrospective evaluation
    T. Chimpandule, H. Tweya, L. Goeke +5
    medRxivPreprintCC BYFull textInfectious diseasemedRxiv
  4. Diagnostic performance of contrast-enhanced transabdominal ultrasound with gastric filling in preoperative T-staging of advanced gastric cancer: a retrospective study.
    Mingjia Lv, Wendi Zou, Yuan Song +4
    Journal of gastrointestinal oncologyPeer-reviewedCC BY-NC-NDFull textOncologyEurope PMC
  5. The clinical significance of baseline lung allograft dysfunction in single and bilateral lung transplant recipients
    Shahrzad M. Lari, Helen Liang, Behzad Dadfar +16
    JHLT openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{imam2026diagnostic,
  title = {{Diagnostic Performance of 99mTc-MAG3 Renal Scintigraphy for Acute Tubular Necrosis and Acute Rejection in Kidney Transplant Recipients with Suspected Graft Dysfunction During the First 90 Days: A Single-Center, Biopsy-Referenced Retrospective Study}},
  author = {Ashraf Imam and Suha Shabaneh and Riham Imam and Michael Rivin and Ahmad Salhab and Itamar Tamir and Keren Tzukert and Roy Abel and Simona Ben-Haim and Harbi Khalayleh and Oded Cohen-Arazi and Abed Khalaileh},
  journal = {Diagnostics (Basel, Switzerland)},
  year = {2026},
  month = oct,
  url = {https://europepmc.org/article/PMC/PMC13664237},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Diagnostic Performance of 99mTc-MAG3 Renal Scintigraphy for Acute Tubular Necrosis and Acute Rejection in Kidney Transplant Recipients with Suspected Graft Dysfunction During the First 90 Days: A Single-Center, Biopsy-Referenced Retrospective Study
AU  - Ashraf Imam
AU  - Suha Shabaneh
AU  - Riham Imam
AU  - Michael Rivin
AU  - Ahmad Salhab
AU  - Itamar Tamir
AU  - Keren Tzukert
AU  - Roy Abel
AU  - Simona Ben-Haim
AU  - Harbi Khalayleh
AU  - Oded Cohen-Arazi
AU  - Abed Khalaileh
PY  - 2026
DA  - 2026/10/01
JO  - Diagnostics (Basel, Switzerland)
UR  - https://europepmc.org/article/PMC/PMC13664237
SN  - 2075-4418
ER  -