Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 55 min ago
Peer-reviewedCC BY 4.0The Egyptian Heart Journal

Recurrent prosthetic valve endocarditis with suspected perivalvular abscess caused by Staphylococcus caprae in a bone marrow transplant recipient: a case report

  1. 1Division of Cardiovascular Surgery, Department of Surgery, Sapporo Medical University, Sapporo, Japan
  2. 2Division of Cardiovascular-Kidney-Metabolic Medicine, Department of Internal Medicine, Sapporo Medical University, Sapporo, Japan
  3. 3Department of Hematology, Sapporo Medical University, Sapporo, Japan

Abstract

Background: Infective endocarditis (IE) in bone marrow transplantation (BMT) recipients is uncommon but carries high mortality. Recurrent prosthetic valve endocarditis (PVE) in immunocompromised hosts presents particular challenges in surgical decision-making. Staphylococcus caprae, a coagulase-negative staphylococcus of caprine origin, is rarely implicated in human IE. We report a rare case of recurrent S. caprae PVE with suspected perivalvular abscess in a BMT recipient managed with advance care planning (ACP) and home-based palliative care.

Case presentation: A 63-year-old male had undergone allogeneic BMT for high-risk myelodysplastic syndrome (MDS) and was receiving immunosuppression for chronic graft-versus-host disease. Approximately 13 months after BMT, he developed cardiogenic shock due to S. caprae IE causing severe aortic regurgitation and underwent emergency aortic valve replacement (AVR) with a 27-mm INSPIRIS RESILIA bioprosthesis (Edwards Lifesciences) and concomitant coronary artery bypass grafting. The initial event has been previously reported. Approximately eight weeks after completion of a 42-day antimicrobial course, he was readmitted with fever and rigors, and blood cultures again grew S. caprae with an antimicrobial susceptibility profile indistinguishable from that of the index isolate; strain-level molecular typing was not performed. Transesophageal echocardiography approximately one month later showed an isoechoic structure at the subaortic curtain, raising suspicion of a perivalvular abscess. Blood cultures remained positive, and a new paravalvular leak developed during follow-up. Through serial multidisciplinary consultations, re-operation was judged to carry prohibitive risk, and the patient declined further surgery. Home-based palliative care with long-term suppressive oral linezolid was chosen in accordance with his preferences. He died peacefully at home with his family approximately 13 months after the index cardiac surgery and 10 months after recurrent bacteremia.

Conclusions: Recurrent S. caprae PVE with suspected perivalvular involvement in a BMT recipient poses difficult management decisions. Residual prosthetic or perivalvular infection is a plausible explanation, but re-infection cannot be excluded. When reoperation is high risk and inconsistent with the patient's wishes, ACP-guided palliative care with suppressive antimicrobial therapy may be an individualized option.

Related

  1. Recurrent Prosthetic Valve Endocarditis With Aortic Root Abscess in Fontan Circulation
    Ahmed Wahba, Sameh M. Said
    JACC Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  2. In-host adaptation of Staphylococcus aureus during recurrent prosthetic joint infections: a retrospective longitudinal study
    Charles Maurille, François Gravey, Jean-Christophe Giard +6
    Microbiology SpectrumPeer-reviewedCC BYInfectious diseaseHAL
  3. From Valve to Spine and Spleen: Multisystem Complications of Gemella haemolysans Prosthetic‐Valve Endocarditis
    Eric Baghdasaryan, Sari Lada, Rafi Orphali +2
    Case Reports in CardiologyPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMCEurope PMC
  4. Prosthetic Aortic Valve Infective Endocarditis Complicated With Malignant Arrhythmias: Diagnostic and Management Challenges
    Imthiaz Manoly, Safia Fathima Anver Pasha, Mohannad M Al Asaad +1
    CureusPeer-reviewedCC BY 4.0Full textInfectious diseasePMC
  5. Surgical Decision‐Making in Staphylococcus aureus Infective Endocarditis With Structural Valve Destruction Despite the Absence of Overt Heart Failure: The Role of the Endocarditis Team
    Muktadir Adnan, Tanyeer Taher, Hridita Ashraf +2
    Clinical Case ReportsPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
BibTeX
@article{nakajima2026recurrent,
  title = {{Recurrent prosthetic valve endocarditis with suspected perivalvular abscess caused by Staphylococcus caprae in a bone marrow transplant recipient: a case report}},
  author = {Tomohiro Nakajima and Yutaka Iba and Tsuyoshi Shibata and Junji Nakazawa and Hidemichi Kouzu and Satoshi Iyama},
  journal = {The Egyptian Heart Journal},
  year = {2026},
  month = nov,
  doi = {10.1186/s43044-026-00803-x},
  url = {https://doi.org/10.1186/s43044-026-00803-x},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Recurrent prosthetic valve endocarditis with suspected perivalvular abscess caused by Staphylococcus caprae in a bone marrow transplant recipient: a case report
AU  - Tomohiro Nakajima
AU  - Yutaka Iba
AU  - Tsuyoshi Shibata
AU  - Junji Nakazawa
AU  - Hidemichi Kouzu
AU  - Satoshi Iyama
PY  - 2026
DA  - 2026/11/16
JO  - The Egyptian Heart Journal
DO  - 10.1186/s43044-026-00803-x
UR  - https://doi.org/10.1186/s43044-026-00803-x
AB  - Background: Infective endocarditis (IE) in bone marrow transplantation (BMT) recipients is uncommon but carries high mortality. Recurrent prosthetic valve endocarditis (PVE) in immunocompromised hosts presents particular challenges in surgical decision-making. Staphylococcus caprae, a coagulase-negative staphylococcus of caprine origin, is rarely implicated in human IE. We report a rare case of recurrent S. caprae PVE with suspected perivalvular abscess in a BMT recipient managed with advance care planning (ACP) and home-based palliative care.  Case presentation: A 63-year-old male had undergone allogeneic BMT for high-risk myelodysplastic syndrome (MDS) and was receiving immunosuppression for chronic graft-versus-host disease. Approximately 13 months after BMT, he developed cardiogenic shock due to S. caprae IE causing severe aortic regurgitation and underwent emergency aortic valve replacement (AVR) with a 27-mm INSPIRIS RESILIA bioprosthesis (Edwards Lifesciences) and concomitant coronary artery bypass grafting. The initial event has been previously reported. Approximately eight weeks after completion of a 42-day antimicrobial course, he was readmitted with fever and rigors, and blood cultures again grew S. caprae with an antimicrobial susceptibility profile indistinguishable from that of the index isolate; strain-level molecular typing was not performed. Transesophageal echocardiography approximately one month later showed an isoechoic structure at the subaortic curtain, raising suspicion of a perivalvular abscess. Blood cultures remained positive, and a new paravalvular leak developed during follow-up. Through serial multidisciplinary consultations, re-operation was judged to carry prohibitive risk, and the patient declined further surgery. Home-based palliative care with long-term suppressive oral linezolid was chosen in accordance with his preferences. He died peacefully at home with his family approximately 13 months after the index cardiac surgery and 10 months after recurrent bacteremia.  Conclusions: Recurrent S. caprae PVE with suspected perivalvular involvement in a BMT recipient poses difficult management decisions. Residual prosthetic or perivalvular infection is a plausible explanation, but re-infection cannot be excluded. When reoperation is high risk and inconsistent with the patient's wishes, ACP-guided palliative care with suppressive antimicrobial therapy may be an individualized option.
SN  - 1110-2608
SN  - 2090-911X
ER  -