Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 36 min ago
Peer-reviewedCC BY 4.0Scientific Reports

A self-adaptive fuzzy pitch control method for suppressing vibration of large-scale wind turbines under combined wind-seismic loading

Abstract

For large-scale wind turbines subjected to sudden seismic excitation during operation, a self-adaptive fuzzy pitch (SFP) control method is proposed to mitigate the structural seismic response. The displacement and velocity of tower-top fore-aft (TTFA) are used as input variables for the fuzzy controller, and a self-adaptive proportional factor is established through an exponential function. The pitch angle adjustment is taken as the output variable, which is then superimposed on the pitch angle given by the baseline pitch controller to realize SFP control. Through co-simulation of OpenFAST and Simulink, the results demonstrate that compared with the traditional proportional–integral (PI) control, the proposed SFP strategy reduces the peak TTFA displacement and acceleration by approximately 25% and 31% on average, respectively, under various earthquake records. Seismic fragility analysis further shows that at a peak ground acceleration (PGA) of 1.0 g, SFP control reduces the failure probabilities corresponding to yield displacement and elastic limit displacement by 43.05% and 20.82%, respectively. These quantitative findings confirm that the proposed method significantly enhances the structural safety of wind turbines under combined wind-seismic loading, providing a practical and robust intelligent control solution for wind farms located in seismically active regions.

Related

  1. Experimental and numerical investigation of voltage-dependent active vibration control on a notch-cracked composite mono leaf spring
    Choon Kit Chan, Rakesh Raushan, Vinod B. Hiwase +5
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study
    Ke Xu, Jiayi Chen, Sijia Deng +2
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Estimation and detection of rotor mass imbalance of wind turbines using convolutional neural network
    Yunqiang Yan
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  4. Improved inhibitory control following combined transcranial direct current stimulation (tDCS) and cognitive training in individuals with traumatic brain injury and impulsivity
    Hamza Jamal, Jazmin Camchong, Kelvin O. Lim +1
    PsyArXivPreprintCC BY 4.0Full textNeurosciencePsychiatry & mental healthOSF
  5. An adaptive cruise control system for autonomous vehicles using PRDC–CoROA-based hybrid optimization
    M. Sivaramkrishnan, M. Siva Ramkumar, Kiruthika Balakrishnan +1
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{xie2026selfadaptive,
  title = {{A self-adaptive fuzzy pitch control method for suppressing vibration of large-scale wind turbines under combined wind-seismic loading}},
  author = {Yunfei Xie and Chenyang Yuan and Weifeng Bai and Peiyu Ma and Yajun Lv and Junfeng Guan},
  journal = {Scientific Reports},
  year = {2026},
  month = sep,
  doi = {10.1038/s41598-026-73352-7},
  url = {https://www.nature.com/articles/s41598-026-73352-7},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A self-adaptive fuzzy pitch control method for suppressing vibration of large-scale wind turbines under combined wind-seismic loading
AU  - Yunfei Xie
AU  - Chenyang Yuan
AU  - Weifeng Bai
AU  - Peiyu Ma
AU  - Yajun Lv
AU  - Junfeng Guan
PY  - 2026
DA  - 2026/09/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-73352-7
UR  - https://www.nature.com/articles/s41598-026-73352-7
AB  - For large-scale wind turbines subjected to sudden seismic excitation during operation, a self-adaptive fuzzy pitch (SFP) control method is proposed to mitigate the structural seismic response. The displacement and velocity of tower-top fore-aft (TTFA) are used as input variables for the fuzzy controller, and a self-adaptive proportional factor is established through an exponential function. The pitch angle adjustment is taken as the output variable, which is then superimposed on the pitch angle given by the baseline pitch controller to realize SFP control. Through co-simulation of OpenFAST and Simulink, the results demonstrate that compared with the traditional proportional–integral (PI) control, the proposed SFP strategy reduces the peak TTFA displacement and acceleration by approximately 25% and 31% on average, respectively, under various earthquake records. Seismic fragility analysis further shows that at a peak ground acceleration (PGA) of 1.0 g, SFP control reduces the failure probabilities corresponding to yield displacement and elastic limit displacement by 43.05% and 20.82%, respectively. These quantitative findings confirm that the proposed method significantly enhances the structural safety of wind turbines under combined wind-seismic loading, providing a practical and robust intelligent control solution for wind farms located in seismically active regions.
SN  - 2045-2322
ER  -