D-dimer in Routine Hospital Practice: Diagnostic Accuracy for Venous Thromboembolism
- 1Medical Biology Department, Faculty of Medicine and Pharmacy, Abdelmalek Essaadi University, Tangier, MAR
- 2Hematology and Immunohematology Laboratory, Mohammed VI University Hospital Center, Tangier, MAR
Abstract
Background
D-dimer is a sensitive rule-out test for venous thromboembolism (VTE), but most validation data come from selected cohorts with suspected embolism, and its performance in unselected hospital populations is less well characterized. We assessed the diagnostic performance of plasma D-dimer for VTE in an unselected hospital population, with pulmonary embolism (PE) as a subgroup, and evaluated the impact of an age-adjusted D-dimer threshold.
Methods
In this one-year retrospective study (May 2025-April 2026), 100 patients were included from 143 consecutive plasma D-dimer requests at a tertiary university hospital in Tangier, Morocco, irrespective of department or clinical indication. D-dimer was measured by immunoturbidimetric assay (threshold 500 ng/mL) and compared with CT pulmonary angiography (CTPA) for PE and venous Doppler ultrasound for deep vein thrombosis (DVT) in patients with a documented reference standard, with PE as a pre-specified subgroup.
Results
The study population (53% female; mean age 55.6 years) had D-dimer requested across many departments, most often adult emergency (54%). Values were right-skewed (median 814 ng/mL); 65% were positive. Imaging confirmed thromboembolic disease in 15 patients, including 12 venous events (nine PE, three DVT), and excluded it in 26. For VTE, sensitivity was 91.7% (95% CI 61.5-99.8) and negative predictive value (NPV) 92.9% (95% CI 66.1-99.8), with specificity 50.0% (95% CI 29.9-70.1), positive predictive value (PPV) 45.8% (95% CI 25.6-67.2) and an area under the curve (AUC) of 0.72 (95% CI 0.55-0.87). For PE, sensitivity and NPV both reached 100% (95% CI 66.4-100.0 and 73.5-100.0), with specificity 52.2% (95% CI 30.6-73.2). An age-adjusted D-dimer threshold raised specificity for VTE to 65.4% without loss of sensitivity.
Conclusion
In this unselected hospital population, plasma D-dimer showed high sensitivity for PE but low specificity, in keeping with its established role as a rule-out test. Its use in routine practice should be guided by clinical pretest probability and, where appropriate, age-adjusted thresholds.
Related
- AI-Assisted Triage for Diabetic Retinopathy Integrated into Routine Diabetes Care: A Real-World Diagnostic Accuracy Study of the DAIRET® Algorithm
- Diagnostic accuracy of standard practice wrist MRI for scapholunate ligament injuries: a retrospective arthroscopic correlation study.
- Impact of an integrated hospital-community care pathway on the management of venous thromboembolism: the venous thromboembolic disease care pathway 93 study
- AGE-related efficacy and safety of darolutamide triplet therapy in metastatic hormone-sensitive prostate cancer: are we ready for routine clinical practice?
- Routine Vitamin and Iron Biomarkers Do Not Explain Variation in Anti-Müllerian Hormone: Implications for Ovarian Reserve Testing in Clinical Practice
BibTeX
@article{abdesselam2026ddimer,
title = {{D-dimer in Routine Hospital Practice: Diagnostic Accuracy for Venous Thromboembolism}},
author = {Ammour Abdesselam and Reda Amrani Souhli and Moussab Arbai and Mouna Houari},
journal = {Cureus},
year = {2026},
month = oct,
doi = {10.7759/cureus.117521},
url = {https://doi.org/10.7759/cureus.117521},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - D-dimer in Routine Hospital Practice: Diagnostic Accuracy for Venous Thromboembolism
AU - Ammour Abdesselam
AU - Reda Amrani Souhli
AU - Moussab Arbai
AU - Mouna Houari
PY - 2026
DA - 2026/10/06
JO - Cureus
DO - 10.7759/cureus.117521
UR - https://doi.org/10.7759/cureus.117521
AB - Background D-dimer is a sensitive rule-out test for venous thromboembolism (VTE), but most validation data come from selected cohorts with suspected embolism, and its performance in unselected hospital populations is less well characterized. We assessed the diagnostic performance of plasma D-dimer for VTE in an unselected hospital population, with pulmonary embolism (PE) as a subgroup, and evaluated the impact of an age-adjusted D-dimer threshold. Methods In this one-year retrospective study (May 2025-April 2026), 100 patients were included from 143 consecutive plasma D-dimer requests at a tertiary university hospital in Tangier, Morocco, irrespective of department or clinical indication. D-dimer was measured by immunoturbidimetric assay (threshold 500 ng/mL) and compared with CT pulmonary angiography (CTPA) for PE and venous Doppler ultrasound for deep vein thrombosis (DVT) in patients with a documented reference standard, with PE as a pre-specified subgroup. Results The study population (53% female; mean age 55.6 years) had D-dimer requested across many departments, most often adult emergency (54%). Values were right-skewed (median 814 ng/mL); 65% were positive. Imaging confirmed thromboembolic disease in 15 patients, including 12 venous events (nine PE, three DVT), and excluded it in 26. For VTE, sensitivity was 91.7% (95% CI 61.5-99.8) and negative predictive value (NPV) 92.9% (95% CI 66.1-99.8), with specificity 50.0% (95% CI 29.9-70.1), positive predictive value (PPV) 45.8% (95% CI 25.6-67.2) and an area under the curve (AUC) of 0.72 (95% CI 0.55-0.87). For PE, sensitivity and NPV both reached 100% (95% CI 66.4-100.0 and 73.5-100.0), with specificity 52.2% (95% CI 30.6-73.2). An age-adjusted D-dimer threshold raised specificity for VTE to 65.4% without loss of sensitivity. Conclusion In this unselected hospital population, plasma D-dimer showed high sensitivity for PE but low specificity, in keeping with its established role as a rule-out test. Its use in routine practice should be guided by clinical pretest probability and, where appropriate, age-adjusted thresholds.
SN - 2168-8184
ER -