Severe Hypercapnia and Hemodynamic Instability During Carbon Dioxide Insufflation During Robot-Assisted Thoracic Surgery
- 1Thoracic Surgery, National Hospital Organization Iwakuni Clinical Center, Iwakuni, JPN
- 2Anesthesia, National Hospital Organization Iwakuni Clinical Center, Iwakuni, JPN
Abstract
The carbon dioxide (CO₂) insufflation system enhances robot-assisted thoracoscopic surgery (RATS) by maintaining a stable capnothorax and facilitating smoke evacuation. However, CO₂ insufflation can cause hypercapnia and hemodynamic instability, requiring vigilant monitoring. We report a case examining the severity and time course of CO₂-induced hypercapnia during capnothorax-assisted robot-assisted thoracoscopic surgery (RATS). A 68-year-old obese man underwent robot-assisted lung resection with capnothorax, resulting in elevated CO₂ levels that caused atrial fibrillation and hypotension. Blood gas analysis showed severe acidosis and hypercapnia. Following discontinuation of the capnothorax, hypercapnia improved within 37 minutes. The surgery was completed successfully without capnothorax, and the patient was discharged on postoperative day 6 without complications. While CO₂ insufflation supports minimally invasive surgery, this case documents an extreme hypercapnic event with an arterial partial pressure of carbon dioxide (PaCO₂) of 110 mmHg with rapid cardiovascular compromise in a high-risk patient using the capnothorax system, underscoring the need for vigilant monitoring, even with advanced insufflation technology.
Related
- Hypotension prediction index to predict hemodynamic instability related to renal replacement therapy in critically ill patients: A prospective observational study
- Tranexamic acid in laparoscopic sleeve gastrectomy: bleeding control amid thrombotic concerns and hemodynamic instability: a randomized double-blinded clinical trial.
- A snare-assisted pull-up technique for side-branch component delivery during thoracic endovascular aortic repair for distal aortic arch aneurysm using Gore Thoracic Branch Endoprosthesis
- Modified dual-portal robotic-assisted thoracic surgery using a Japanese-manufactured robotic platform
- AI-assisted 3D thoracic body composition analysis identifies candidate imaging markers associated with overall survival in older patients with lung cancer receiving radiotherapy
BibTeX
@article{watanabe2026severe,
title = {{Severe Hypercapnia and Hemodynamic Instability During Carbon Dioxide Insufflation During Robot-Assisted Thoracic Surgery}},
author = {Mototsugu Watanabe and Noriaki Shiraha and Yoshinobu Shikatani and Kenji Uehara},
journal = {Cureus},
year = {2026},
month = sep,
doi = {10.7759/cureus.117142},
url = {https://europepmc.org/article/PMC/PMC13718260},
note = {CC BY},
}
RIS
TY - JOUR
TI - Severe Hypercapnia and Hemodynamic Instability During Carbon Dioxide Insufflation During Robot-Assisted Thoracic Surgery
AU - Mototsugu Watanabe
AU - Noriaki Shiraha
AU - Yoshinobu Shikatani
AU - Kenji Uehara
PY - 2026
DA - 2026/09/29
JO - Cureus
DO - 10.7759/cureus.117142
UR - https://europepmc.org/article/PMC/PMC13718260
AB - The carbon dioxide (CO₂) insufflation system enhances robot-assisted thoracoscopic surgery (RATS) by maintaining a stable capnothorax and facilitating smoke evacuation. However, CO₂ insufflation can cause hypercapnia and hemodynamic instability, requiring vigilant monitoring. We report a case examining the severity and time course of CO₂-induced hypercapnia during capnothorax-assisted robot-assisted thoracoscopic surgery (RATS). A 68-year-old obese man underwent robot-assisted lung resection with capnothorax, resulting in elevated CO₂ levels that caused atrial fibrillation and hypotension. Blood gas analysis showed severe acidosis and hypercapnia. Following discontinuation of the capnothorax, hypercapnia improved within 37 minutes. The surgery was completed successfully without capnothorax, and the patient was discharged on postoperative day 6 without complications. While CO₂ insufflation supports minimally invasive surgery, this case documents an extreme hypercapnic event with an arterial partial pressure of carbon dioxide (PaCO₂) of 110 mmHg with rapid cardiovascular compromise in a high-risk patient using the capnothorax system, underscoring the need for vigilant monitoring, even with advanced insufflation technology.
SN - 2168-8184
ER -