Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 43 min ago
PreprintCC BY-SA 4.0arXiv

You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution

Abstract

Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.

Related

  1. Understanding the high-resolution spectral signatures of Ar-D2O in the 3OD stretch region measured by cavity ringdown absorption spectroscopy
    R. Glorieux, A. S. Bogomolov, M. Herman +3
    Molecular PhysicsPeer-reviewedLicence not statedPhysical chemistryGeneral physicsHAL
  2. Experimental Ni II Oscillator Strengths for Transitions from 3d84d to 3d84p Levels Measured Using High-resolution Fourier Transform Spectroscopy
    Ruijie Chen, Christian P. Clear, Gillian Nave +1
    arXivPreprintCC BY 4.0Full textSolar & stellar physicsAtomic, molecular & optical physicsarXiv
  3. Quantifying Information Hierarchy for Neutrino Oscillation Parameters at JUNO
    Yu-han Shu, Neetu Raj Singh Chundawat, Luis A. Delgadillo +1
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsQuantum physics & quantum informationarXiv
  4. Prior-information based super-resolution optical metrology of 2D nanoscale objects
    Jin-Kyu So, Eng Aik Chan, Carolina Rendón-Barraza +2
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
  5. Adaptive Information Mining: Approaching the Quantum Limit of Super-Resolution Imaging
    Seungman Choi, Peter Menart, Andrew Schramka +1
    arXivPreprintarXiv licenceFull textOptics & photonicsQuantum physics & quantum informationarXiv
BibTeX
@misc{khole2026cannot,
  title = {{You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution}},
  author = {Prathamesh Pradeep Khole and Shreya Handa and Utkarsh Gupta and Razvan Marinescu},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.36837},
  eprint = {2609.36837},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.36837},
  note = {CC BY-SA 4.0},
}
RIS
TY  - UNPB
TI  - You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution
AU  - Prathamesh Pradeep Khole
AU  - Shreya Handa
AU  - Utkarsh Gupta
AU  - Razvan Marinescu
PY  - 2026
DA  - 2026/09/29
PB  - arXiv
DO  - 10.48550/arxiv.2609.36837
UR  - https://arxiv.org/abs/2609.36837
AB  - Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.
ER  -