Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BY 4.0Diagnostics

Effect of the Measurement Interface on Maximal Expiratory Pressure During Voluntary Cough in Young Adults

4 affiliations
  1. 1Postdoctorado en Ciencias Morfológicas, Universidad de La Frontera, Temuco 4811230, Chile
  2. 2Escuele de Kinesiología, Universidad Católica del Maule, Talca 4811230, Chile; (C.V.G.); (F.Y.Q.); (P.M.-G.); (M.E.-C.)
  3. 3Centro de Excelencia en Estudios Morfológicos y Quirúrgicos, Universidad de La Frontera, Temuco 4811230, Chile
  4. 4Departamento de Neurología Pediátrica, Escuela de Medicina, Pontificia Universidad Católica de Chile, Santiago 8320165, Chile

Abstract

Background/Objectives: To determine whether there are differences between a nozzle and an oronasal mask in the measurement of maximal expiratory pressure (MEP) during a voluntary cough maneuver in young university students. Methods: Forty university students aged 20–25 years were recruited, comprising 20 males and 20 females. Forced vital capacity and MEP were measured during a voluntary cough maneuver. All participants were assessed using both interfaces. The order of the interfaces used to measure MEP during the voluntary cough maneuver was randomized, once the order was determined, the evaluations were conducted on two separate days: one for the nozzle and another for the oronasal mask. Subsequently, participants were asked to report their perception of air leakage and comfort associated with each device. Results: There was no significant main effect of the interface on MEP after adjusting for gender, peak expiratory flow (PEF), and body mass index (BMI) (F(1.36) = 3.285; p = 0.078; η2p = 0.084). There was a significant interaction between interface and BMI (F(1,36) = 6.391; p = 0.016; η2p = 0.151). Gender and PEF were significantly associated with MEP (gender: F(1,36) = 16.698; p < 0.001; η2p = 0.317; PEF: F(1,36) = 8.985; p = 0.005; η2p = 0.200). Conclusions: In young adults, the measurement interface alone did not significantly alter MEP. The relationship between BMI and MEP varied according to the interface used, as evidenced by the interface × BMI interaction; gender and PEF were significantly associated with MEP.

Related

  1. Geniohyoid Muscle and Diaphragm Ultrasonography and Maximal Expiratory Pressure During Four Weeks of Expiratory Muscle Strength Training in Healthy Young Men: An Exploratory Pilot Study.
    Shinichi Watanabe, Riku Hirayama, Haruto Miyata +6
    Muscles (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Effect of intraoperative high positive end-expiratory pressure with recruitment manoeuvres versus low positive end-expiratory pressure on postoperative lung function in obese adults: a substudy of the protective ventilation in obese patients randomised controlled trial
    Damien Rousseleau, Thomas Bluth, Bas Bruneel +5
    BJA openPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Right-left discordance of pulmonary artery wedge pressure under high positive end-expiratory pressure in acute eccentric mitral regurgitation
    European heart journal. Case reportsPeer-reviewedCC BY-NCFull textCardiovascular medicineEurope PMC
  4. Dietary nitrate does not alter the rate of torque development during maximal voluntary isometric or electrically evoked tetanic contractions in young men or women
    Lenna K. Gottschild, Jay P. Pillai, Madison J. Fry +3
    bioRxivPreprintCC BY-NC-NDFull textPhysiologybioRxivPMC
  5. Effect of Metatarsophalangeal Joint Position on Maximal Voluntary Isometric Ankle Plantar‐Flexion Torque
    Hiroto Shiotani, Katsuki Takahashi, Kosei Taniai +2
    Scandinavian journal of medicine & science in sportsPeer-reviewedCC BYFull textGeneral medicineEurope PMCEurope PMCPMC
BibTeX
@article{munozcofre2026effect,
  title = {{Effect of the Measurement Interface on Maximal Expiratory Pressure During Voluntary Cough in Young Adults}},
  author = {Rodrigo Muñoz-Cofré and Cristian Villar Gonzalez and Francisca Yáñez Quiñones and Paul Medina-González and Mariano del Sol and Raúl Escobar Henríquez and Máximo Escobar-Cabello},
  journal = {Diagnostics},
  year = {2026},
  month = nov,
  doi = {10.3390/diagnostics16213626},
  url = {https://doi.org/10.3390/diagnostics16213626},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Effect of the Measurement Interface on Maximal Expiratory Pressure During Voluntary Cough in Young Adults
AU  - Rodrigo Muñoz-Cofré
AU  - Cristian Villar Gonzalez
AU  - Francisca Yáñez Quiñones
AU  - Paul Medina-González
AU  - Mariano del Sol
AU  - Raúl Escobar Henríquez
AU  - Máximo Escobar-Cabello
PY  - 2026
DA  - 2026/11/03
JO  - Diagnostics
DO  - 10.3390/diagnostics16213626
UR  - https://doi.org/10.3390/diagnostics16213626
AB  - Background/Objectives: To determine whether there are differences between a nozzle and an oronasal mask in the measurement of maximal expiratory pressure (MEP) during a voluntary cough maneuver in young university students. Methods: Forty university students aged 20–25 years were recruited, comprising 20 males and 20 females. Forced vital capacity and MEP were measured during a voluntary cough maneuver. All participants were assessed using both interfaces. The order of the interfaces used to measure MEP during the voluntary cough maneuver was randomized, once the order was determined, the evaluations were conducted on two separate days: one for the nozzle and another for the oronasal mask. Subsequently, participants were asked to report their perception of air leakage and comfort associated with each device. Results: There was no significant main effect of the interface on MEP after adjusting for gender, peak expiratory flow (PEF), and body mass index (BMI) (F(1.36) = 3.285; p = 0.078; η2p = 0.084). There was a significant interaction between interface and BMI (F(1,36) = 6.391; p = 0.016; η2p = 0.151). Gender and PEF were significantly associated with MEP (gender: F(1,36) = 16.698; p < 0.001; η2p = 0.317; PEF: F(1,36) = 8.985; p = 0.005; η2p = 0.200). Conclusions: In young adults, the measurement interface alone did not significantly alter MEP. The relationship between BMI and MEP varied according to the interface used, as evidenced by the interface × BMI interaction; gender and PEF were significantly associated with MEP.
SN  - 2075-4418
ER  -