Comparison of Standing, Prone, and Sitting Protocols for Knee Joint Position Sense Testing in Non-Athletic Adolescent Females: A Non-Weight-Bearing Open Kinetic Chain Study.
5 affiliations
- 1Institute for Children and Youth Healthcare of Vojvodina, 21000 Novi Sad, Serbia.
- 2Department of Surgery, Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
- 3University Clinical Center of Vojvodina, 21000 Novi Sad, Serbia.
- 4Faculty of Sport and Physical Education, University of Novi Sad, 21000 Novi Sad, Serbia.
- 5Training Expertise, 21000 Novi Sad, Serbia.
Abstract
Background/Objectives: Knee joint position sense (KJPS) assessment lacks standardized testing protocols, and it remains unclear how commonly used non-weight-bearing protocols-standing, prone, and sitting-and target angle influence reproduction error. This study aimed to compare KJPS error across these three protocols and three target knee-flexion angles (30°, 45°, 60°) in non-athletic adolescent females. Methods: In this within-subjects study, 30 non-athletic female participants aged 15-18 years (16.47 ± 1.04) performed an active angle-reproduction task with the tested limb non-weight-bearing, recorded using a VICON motion analysis system. Absolute Error (AE) and Constant Error (CE) were calculated, together with the between-participant dispersion of CE (SD-CE). Results: AE showed a significant main effect of protocol (F = 4.33, p = 0.018, ηp² = 0.130), confirmed by permutation testing, but no significant angle effect or interaction. Sitting produced lower AE than prone testing (mean difference = 2.98°, Holm-adjusted p = 0.023). CE was significantly positive in all nine conditions, confirming a systematic tendency to overshoot the target angle. SD-CE was lowest in sitting, intermediate in standing, and highest in prone. Conclusions: Testing protocol influenced KJPS accuracy and between-participant dispersion, whereas no target-angle effect was detected within the tested protocol configurations. The sitting protocol emerged as a promising candidate for further reliability and standardization research in this population.
Related
- Relationships between physical fitness and early standing-start kinematic characteristics in adolescent male track cyclists.
- Transperineal Ultrasound Comparison of Longitudinal Sling Position and Dynamic Sling Configuration After Altis and MiniStop Single-Incision Mini-Slings for Stress Urinary Incontinence
- Comparison of coronal alignment measured on postoperative short-leg and standing long-leg radiographs following total knee arthroplasty.
- A comparison of intravenous-only and intra-articular-plus-intravenous protocols of autologous conditioned serum in dogs with hip osteoarthritis—a retrospective study
- Comparison of the efficacy between modified prone split-leg position and lithotomy position in retrograde intrarenal surgery for upper urinary tract calculi
BibTeX
@article{milankov2026comparison,
title = {{Comparison of Standing, Prone, and Sitting Protocols for Knee Joint Position Sense Testing in Non-Athletic Adolescent Females: A Non-Weight-Bearing Open Kinetic Chain Study.}},
author = {Vukadin Milankov and Boris Privrodski and Miodrag Vranješ and Andrijana Milankov and Srđan Ninković and Nikola Andrić and Marko D M Stojanović},
journal = {Journal of functional morphology and kinesiology},
year = {2026},
month = oct,
doi = {10.3390/jfmk11040447},
url = {https://europepmc.org/article/MED/43081347},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparison of Standing, Prone, and Sitting Protocols for Knee Joint Position Sense Testing in Non-Athletic Adolescent Females: A Non-Weight-Bearing Open Kinetic Chain Study.
AU - Vukadin Milankov
AU - Boris Privrodski
AU - Miodrag Vranješ
AU - Andrijana Milankov
AU - Srđan Ninković
AU - Nikola Andrić
AU - Marko D M Stojanović
PY - 2026
DA - 2026/10/25
JO - Journal of functional morphology and kinesiology
DO - 10.3390/jfmk11040447
UR - https://europepmc.org/article/MED/43081347
AB - Background/Objectives: Knee joint position sense (KJPS) assessment lacks standardized testing protocols, and it remains unclear how commonly used non-weight-bearing protocols-standing, prone, and sitting-and target angle influence reproduction error. This study aimed to compare KJPS error across these three protocols and three target knee-flexion angles (30°, 45°, 60°) in non-athletic adolescent females. Methods: In this within-subjects study, 30 non-athletic female participants aged 15-18 years (16.47 ± 1.04) performed an active angle-reproduction task with the tested limb non-weight-bearing, recorded using a VICON motion analysis system. Absolute Error (AE) and Constant Error (CE) were calculated, together with the between-participant dispersion of CE (SD-CE). Results: AE showed a significant main effect of protocol (F = 4.33, p = 0.018, ηp² = 0.130), confirmed by permutation testing, but no significant angle effect or interaction. Sitting produced lower AE than prone testing (mean difference = 2.98°, Holm-adjusted p = 0.023). CE was significantly positive in all nine conditions, confirming a systematic tendency to overshoot the target angle. SD-CE was lowest in sitting, intermediate in standing, and highest in prone. Conclusions: Testing protocol influenced KJPS accuracy and between-participant dispersion, whereas no target-angle effect was detected within the tested protocol configurations. The sitting protocol emerged as a promising candidate for further reliability and standardization research in this population.
SN - 2411-5142
ER -