Experimental Investigation of Tear Strength, Stress Relaxation, and Anisotropy of Polypropylene Surgical Meshes
- 1Faculty of Mechanical Engineering, PK Krakow University of Technology, 24 Warszawska Street, 31-155 Krakow, Poland
Abstract
In this study, the mechanical behavior of polypropylene surgical meshes was investigated with a focus on tear strength, stress relaxation, and anisotropy. Four commercially available meshes with different structural architectures and grammages were tested. Mechanical characterization was performed by means of trouser tear tests and stress relaxation tests conducted for 1 h at a constant strain of 20%. Tear strength, secant stiffness, apparent Young’s modulus, initial and residual stresses, and normalized relaxation response were determined, and the anisotropic behavior of the meshes was evaluated in two orthogonal directions. Significant differences were observed among the investigated meshes. Materials with higher grammage and more compact structures exhibited greater tear strength, whereas lighter meshes showed lower strength and increased susceptibility to tear propagation. All meshes demonstrated pronounced viscoelastic behavior, characterized by an initial rapid stress decay followed by slower relaxation processes and gradual stabilization. The absolute stress response and stiffness were strongly dependent on mesh structure and loading direction, whereas normalized stress relaxation parameters were largely independent of orientation. The combined evaluation of tear resistance and time-dependent mechanical response highlights the importance of structural parameters and anisotropy in determining the performance of surgical meshes. These findings contribute to a better understanding of mesh mechanical behavior and may support the optimization of mesh design and the development of implants with improved durability and mechanical reliability under physiological loading conditions.
Related
- Experimental investigation of fiber hybridized ECC using PVA, polypropylene, and high-modulus glass fibers with class F Fly ash and OPC
- A Strength‑Based Neurodiversity‑Affirming Investigation of Digital Interventions for Autistic Children in China: Multi‑Perspective Thematic Analysis With Parents and Therapists
- Nutritional profiling and pharmacological investigation of Baccaurea motleyana peel and seed through experimental and computational approach
- Experimental investigation of pile diameter and group configuration effects on soil pile interaction and lateral group efficiency in sand
- Experimental and theoretical investigation of parameter-driven stability and chaos in a non-linear neuron circuit model
BibTeX
@article{lagan2026experimental,
title = {{Experimental Investigation of Tear Strength, Stress Relaxation, and Anisotropy of Polypropylene Surgical Meshes}},
author = {Sylwia Łagan},
journal = {Polymers},
year = {2026},
month = oct,
doi = {10.3390/polym18202595},
url = {https://www.mdpi.com/2073-4360/18/20/2595},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Experimental Investigation of Tear Strength, Stress Relaxation, and Anisotropy of Polypropylene Surgical Meshes
AU - Sylwia Łagan
PY - 2026
DA - 2026/10/21
JO - Polymers
DO - 10.3390/polym18202595
UR - https://www.mdpi.com/2073-4360/18/20/2595
AB - In this study, the mechanical behavior of polypropylene surgical meshes was investigated with a focus on tear strength, stress relaxation, and anisotropy. Four commercially available meshes with different structural architectures and grammages were tested. Mechanical characterization was performed by means of trouser tear tests and stress relaxation tests conducted for 1 h at a constant strain of 20%. Tear strength, secant stiffness, apparent Young’s modulus, initial and residual stresses, and normalized relaxation response were determined, and the anisotropic behavior of the meshes was evaluated in two orthogonal directions. Significant differences were observed among the investigated meshes. Materials with higher grammage and more compact structures exhibited greater tear strength, whereas lighter meshes showed lower strength and increased susceptibility to tear propagation. All meshes demonstrated pronounced viscoelastic behavior, characterized by an initial rapid stress decay followed by slower relaxation processes and gradual stabilization. The absolute stress response and stiffness were strongly dependent on mesh structure and loading direction, whereas normalized stress relaxation parameters were largely independent of orientation. The combined evaluation of tear resistance and time-dependent mechanical response highlights the importance of structural parameters and anisotropy in determining the performance of surgical meshes. These findings contribute to a better understanding of mesh mechanical behavior and may support the optimization of mesh design and the development of implants with improved durability and mechanical reliability under physiological loading conditions.
SN - 2073-4360
ER -