Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY-NC-NDJournal of vascular surgery cases and innovative techniques

Mechanism-guided endograft explantation eliminates shear-mediated aortic injury in a controlled simulation study.

  1. 1Texas A&M School of Engineering Medicine, Houston, TX.
  2. 2Department of Cardiovascular Surgery, Houston Methodist Hospital, Houston, TX.

Abstract

Objective

Endograft explantation is associated with high morbidity and mortality, driven in part by uncontrolled shear-mediated aortic injury. In this study, we evaluated whether a mechanism-based explantation device could reduce this injury and improve the procedural performance.Methods

In a controlled simulation using a multilayered three-dimensional printed aortic model, 25 vascular trainees and surgeons performed endograft explantation using both a conventional syringe technique and a novel device (EndoEx). The outcomes included quantitative intimal injury, procedure time, and validated usability metrics.Results

The EndoEx device reduced intimal injury by approximately 90% compared with the syringe technique (0.94% vs 9.56%; P < .001), representing near-elimination of shear-mediated disruption. The procedure time was moderately longer (+32 seconds; P < .05). EndoEx demonstrated superior usability across all domains, including ease of use, safety perception, and overall cognitive load (P < .05).Conclusions

In this controlled simulation, a mechanism-based explantation strategy (EndoEx) markedly reduced shear-mediated aortic injury while improving operator control. These findings support further in vivo evaluation and establish a mechanistic foundation for a device-based approach to endovascular aneurysm repair explantation that warrants clinical validation.

Related

  1. Surgical explantation following early transcatheter aortic valve failure: Technical considerations for complex situations.
    R Michael Reul, Alexander P Nissen, Bradley G Leshnower
    JTCVS structural and endovascularPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Surgical aortic valve replacement-level aortotomy for self-expanding transcatheter aortic valve explantation
    Israa Saleh, Raymond L. Benza, Deepak R. Talreja +3
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Opioid Withdrawal Following Intrathecal Morphine Pump Explantation Managed with a Structured Oral Opioid Taper: A Case Study
    Jamal Hasoon, Preetash Sundar, Omar Viswanath +3
    Psychopharmacology BulletinPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  4. Case Report: A case of severe chronic infection of an intraperitoneally placed composite mesh treated with complete mesh explantation and primary tissue repair using the anterior component separation technique
    Branko Bakula, Marko Sever, Ante Ivkošić +4
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Functional pseudocoarctation after branched arch endograft implantation in a patient with previous type A aortic dissection repair
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{moin2026mechanismguided,
  title = {{Mechanism-guided endograft explantation eliminates shear-mediated aortic injury in a controlled simulation study.}},
  author = {Zain Moin and Alayne Morrel and Maham Rahimi},
  journal = {Journal of vascular surgery cases and innovative techniques},
  year = {2026},
  month = sep,
  doi = {10.1016/j.jvscit.2026.102489},
  url = {https://europepmc.org/article/MED/42904182},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Mechanism-guided endograft explantation eliminates shear-mediated aortic injury in a controlled simulation study.
AU  - Zain Moin
AU  - Alayne Morrel
AU  - Maham Rahimi
PY  - 2026
DA  - 2026/09/03
JO  - Journal of vascular surgery cases and innovative techniques
DO  - 10.1016/j.jvscit.2026.102489
UR  - https://europepmc.org/article/MED/42904182
AB  - Objective  Endograft explantation is associated with high morbidity and mortality, driven in part by uncontrolled shear-mediated aortic injury. In this study, we evaluated whether a mechanism-based explantation device could reduce this injury and improve the procedural performance.Methods  In a controlled simulation using a multilayered three-dimensional printed aortic model, 25 vascular trainees and surgeons performed endograft explantation using both a conventional syringe technique and a novel device (EndoEx). The outcomes included quantitative intimal injury, procedure time, and validated usability metrics.Results  The EndoEx device reduced intimal injury by approximately 90% compared with the syringe technique (0.94% vs 9.56%; P < .001), representing near-elimination of shear-mediated disruption. The procedure time was moderately longer (+32 seconds; P < .05). EndoEx demonstrated superior usability across all domains, including ease of use, safety perception, and overall cognitive load (P < .05).Conclusions  In this controlled simulation, a mechanism-based explantation strategy (EndoEx) markedly reduced shear-mediated aortic injury while improving operator control. These findings support further in vivo evaluation and establish a mechanistic foundation for a device-based approach to endovascular aneurysm repair explantation that warrants clinical validation.
SN  - 2468-4287
ER  -