The Simons Observatory: Analysis of methods for polarization calibration of multiple instruments
Abstract
Cosmic birefringence, the rotation of the CMB linear polarization plane across the Universe, is a powerful test of parity-violating physics beyond the Standard Model. Static isotropic rotation, however, is limited by an instrument's absolute polarization-angle calibration. We present a method for transferring absolute calibration between Simons Observatory (SO) instruments, validated on map-level simulations of the Large Aperture Telescope (LAT) and Small Aperture Telescopes (SATs) with lensed CMB polarization, polarized Galactic foregrounds, correlated instrumental noise, and polarization-angle miscalibration. We develop two pipelines: a joint LAT+SAT likelihood transferring calibration through their overlap, and the Minami-Komatsu foreground-based method, which separates cosmic birefringence from instrumental miscalibration using Galactic dust polarization without an external angle prior. We derive a general variance budget showing that calibration transfer improves sensitivity only when the combined reference and overlap transfer uncertainties remain below the receiving instrument's calibration uncertainty. While transfer does not lower the absolute-angle floor for isotropic β, it anchors the receiving instrument's multipole range. The relative-angle uncertainty is ∼ 0.1∘ for ℓmaxSAT=300, improving to ∼ 0.04∘ at ℓmaxSAT=600, subject to SAT beam and transfer-function control. Finally, for β=0.3∘, we show how the LAT's ℓ-range distinguishes scale-independent dark-energy rotation from scale-dependent axion dark-matter models via CℓEB.
Related
- Extended Bayesian Estimation for In-flight Calibration of Space-based Instruments
- The Simons Observatory: Overview of the Cryogenic Half-wave Plate Polarization Modulators
- The Simons Observatory: Rotation Performance of Cryogenic Half-Wave Plate Polarization Modulators
- The Simons Observatory: Frequency-resolved beam calibration for the SO SATs with POLOCALC
- A data-driven absolute amplitude calibration for the Radio Neutrino Observatory Greenland (RNO-G)
BibTeX
@misc{collaboration2026simons,
title = {{The Simons Observatory: Analysis of methods for polarization calibration of multiple instruments}},
author = {The Simons Observatory Collaboration and Anto I. Lonappan and Patricia Diego-Palazuelos and Carlos Hervías-Caimapo and Kam Arnold and Susanna Azzoni and Carlo Baccigalupi and Matteo Billi and Erminia Calabrese and Yuji Chinone and Matthew Chu and Mark Devlin and Josquin Errard and Nicholas Galitzki and Bradley R. Johnson and Brian Keating and Andréa Landais and Toshiya Namikawa and Federico Nati and Giuseppe Puglisi and Christian L. Reichardt and Kevin Wolz},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.31235},
eprint = {2611.31235},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.31235},
}
RIS
TY - UNPB
TI - The Simons Observatory: Analysis of methods for polarization calibration of multiple instruments
AU - The Simons Observatory Collaboration
AU - Anto I. Lonappan
AU - Patricia Diego-Palazuelos
AU - Carlos Hervías-Caimapo
AU - Kam Arnold
AU - Susanna Azzoni
AU - Carlo Baccigalupi
AU - Matteo Billi
AU - Erminia Calabrese
AU - Yuji Chinone
AU - Matthew Chu
AU - Mark Devlin
AU - Josquin Errard
AU - Nicholas Galitzki
AU - Bradley R. Johnson
AU - Brian Keating
AU - Andréa Landais
AU - Toshiya Namikawa
AU - Federico Nati
AU - Giuseppe Puglisi
AU - Christian L. Reichardt
AU - Kevin Wolz
PY - 2026
DA - 2026/11/23
PB - arXiv
DO - 10.48550/arxiv.2611.31235
UR - https://arxiv.org/abs/2611.31235
AB - Cosmic birefringence, the rotation of the CMB linear polarization plane across the Universe, is a powerful test of parity-violating physics beyond the Standard Model. Static isotropic rotation, however, is limited by an instrument's absolute polarization-angle calibration. We present a method for transferring absolute calibration between Simons Observatory (SO) instruments, validated on map-level simulations of the Large Aperture Telescope (LAT) and Small Aperture Telescopes (SATs) with lensed CMB polarization, polarized Galactic foregrounds, correlated instrumental noise, and polarization-angle miscalibration. We develop two pipelines: a joint LAT+SAT likelihood transferring calibration through their overlap, and the Minami-Komatsu foreground-based method, which separates cosmic birefringence from instrumental miscalibration using Galactic dust polarization without an external angle prior. We derive a general variance budget showing that calibration transfer improves sensitivity only when the combined reference and overlap transfer uncertainties remain below the receiving instrument's calibration uncertainty. While transfer does not lower the absolute-angle floor for isotropic β, it anchors the receiving instrument's multipole range. The relative-angle uncertainty is ∼ 0.1^∘ for ℓ_max^SAT=300, improving to ∼ 0.04^∘ at ℓ_max^SAT=600, subject to SAT beam and transfer-function control. Finally, for β=0.3^∘, we show how the LAT's ℓ-range distinguishes scale-independent dark-energy rotation from scale-dependent axion dark-matter models via C_ℓ^EB.
ER -