Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYJournal of eye movement research

Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.

4 affiliations
  1. 1Institute of Information Technologies, MIREA-Russian Technological University, Moscow 119454, Russia.
  2. 2Department of Hospital Surgery, Sechenov First Moscow State Medical University, Moscow 119992, Russia.
  3. 3Psychiatric Day Hospital Department, Mental-Health Clinic No. 1 Named After N.A. Alexeev, Moscow 117152, Russia.
  4. 4Institute of Cybersecurity and Digital Technologies, MIREA-Russian Technological University, Moscow 119454, Russia.

Abstract

The frequency characteristic of biological systems is a sensitive tool for describing physiological dynamics, yet it has been virtually unused in pupillometry. A novel eye-tracking feature is proposed-the amplitude-frequency characteristic (AFC) of the "stimulus-pupil size" system-and evaluated as a candidate diagnostic marker on an open ADHD dataset. After quality control, 61 sessions (18 controls, 27 unmedicated ADHD, 16 on-medication ADHD) were analyzed. The AFC of the raw diameter signal reveals a systematic elevation of AFC amplitude in ADHD across the 0.5-30 Hz range, strongest in the 20-30 Hz band (Cohen's d = +0.995, p = 0.0034). This is a pilot and methodology- and reproducibility-focused study. At the individual diagnostic level, a normative composite z-score of three bands (10-15, 15-20, 20-30 Hz), computed relative to the control group with fixed weights and no training, reaches an ROC-AUC = 0.788 (Ctrl vs. off-ADHD: p = 0.0012). At the group level, a linear discriminant projection of the eight-band profile reaches an ROC-AUC = 0.854. The inter-individual variability of within-subject AFC stability is reduced by a factor of 2.97 in unmedicated ADHD (p = 0.0085) and normalizes under methylphenidate (paired Wilcoxon p = 0.0067, n = 17). The widely used ratio of high- to low-frequency AFC amplitude yields an inflated ROC-AUC of 0.865 on the pre-filtered signal, but only 0.63 on the raw signal. All diagnostic claims are exploratory. The proposed normative feature is simple, interpretable, requires no training set, and can be computed from a single pupil recording.

Related

  1. Fractional amplitude of low-frequency fluctuations (fALFF) changes in children with anisometropic amblyopia : A resting-state fMRI study
    Xueliang Yu, Lisheng Zhao, Weizhao Lu +6
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Prognostic Value of Infarct-Zone Circumferential Strain by CMR Feature Tracking After Acute Myocardial Infarction Treated with Primary PCI
    Danzeng Quyang, Qingchen Zhang, Huoyuan Xiao +4
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Bone Marrow Dominant Erdheim-Chester Disease Lacking Characteristic Radiologic Findings: A Diagnostic Pitfall.
    Elsire Boulanger Laborit, Sarisha Naidoo, Habib Moshref Razavi
    EJHaemPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  4. Efficacy Evaluation of Repetitive Transcranial Magnetic Stimulation at Individual Frequency for Patients With Prolonged Disorders of Consciousness: A Preliminary Study Based on Mismatch Negative Amplitude.
    Yu-Qin Zhao, Lin-Xi Li, Nuan Yang +9
    Brain and behaviorPeer-reviewedCC BYFull textNeurologyEurope PMC
  5. Diagnostic Feature Associations in Atypical Parkinsonian Disorders: A Survey of Movement Disorders Specialists
    C. Zweber, V. Iyer, E. Houston +4
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
BibTeX
@article{nikulchev2026amplitudefrequency,
  title = {{Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.}},
  author = {Evgeny Nikulchev and Alexander N Kosenkov and Andrey Sokolov and Anna Alexeenko and Dmitry Ilin},
  journal = {Journal of eye movement research},
  year = {2026},
  month = oct,
  doi = {10.3390/jemr19060124},
  url = {https://europepmc.org/article/MED/43081580},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.
AU  - Evgeny Nikulchev
AU  - Alexander N Kosenkov
AU  - Andrey Sokolov
AU  - Anna Alexeenko
AU  - Dmitry Ilin
PY  - 2026
DA  - 2026/10/30
JO  - Journal of eye movement research
DO  - 10.3390/jemr19060124
UR  - https://europepmc.org/article/MED/43081580
AB  - The frequency characteristic of biological systems is a sensitive tool for describing physiological dynamics, yet it has been virtually unused in pupillometry. A novel eye-tracking feature is proposed-the amplitude-frequency characteristic (AFC) of the "stimulus-pupil size" system-and evaluated as a candidate diagnostic marker on an open ADHD dataset. After quality control, 61 sessions (18 controls, 27 unmedicated ADHD, 16 on-medication ADHD) were analyzed. The AFC of the raw diameter signal reveals a systematic elevation of AFC amplitude in ADHD across the 0.5-30 Hz range, strongest in the 20-30 Hz band (Cohen's d = +0.995, p = 0.0034). This is a pilot and methodology- and reproducibility-focused study. At the individual diagnostic level, a normative composite z-score of three bands (10-15, 15-20, 20-30 Hz), computed relative to the control group with fixed weights and no training, reaches an ROC-AUC = 0.788 (Ctrl vs. off-ADHD: p = 0.0012). At the group level, a linear discriminant projection of the eight-band profile reaches an ROC-AUC = 0.854. The inter-individual variability of within-subject AFC stability is reduced by a factor of 2.97 in unmedicated ADHD (p = 0.0085) and normalizes under methylphenidate (paired Wilcoxon p = 0.0067, n = 17). The widely used ratio of high- to low-frequency AFC amplitude yields an inflated ROC-AUC of 0.865 on the pre-filtered signal, but only 0.63 on the raw signal. All diagnostic claims are exploratory. The proposed normative feature is simple, interpretable, requires no training set, and can be computed from a single pupil recording.
SN  - 1995-8692
ER  -