Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.
4 affiliations
- 1Institute of Information Technologies, MIREA-Russian Technological University, Moscow 119454, Russia.
- 2Department of Hospital Surgery, Sechenov First Moscow State Medical University, Moscow 119992, Russia.
- 3Psychiatric Day Hospital Department, Mental-Health Clinic No. 1 Named After N.A. Alexeev, Moscow 117152, Russia.
- 4Institute of Cybersecurity and Digital Technologies, MIREA-Russian Technological University, Moscow 119454, Russia.
Abstract
The frequency characteristic of biological systems is a sensitive tool for describing physiological dynamics, yet it has been virtually unused in pupillometry. A novel eye-tracking feature is proposed-the amplitude-frequency characteristic (AFC) of the "stimulus-pupil size" system-and evaluated as a candidate diagnostic marker on an open ADHD dataset. After quality control, 61 sessions (18 controls, 27 unmedicated ADHD, 16 on-medication ADHD) were analyzed. The AFC of the raw diameter signal reveals a systematic elevation of AFC amplitude in ADHD across the 0.5-30 Hz range, strongest in the 20-30 Hz band (Cohen's d = +0.995, p = 0.0034). This is a pilot and methodology- and reproducibility-focused study. At the individual diagnostic level, a normative composite z-score of three bands (10-15, 15-20, 20-30 Hz), computed relative to the control group with fixed weights and no training, reaches an ROC-AUC = 0.788 (Ctrl vs. off-ADHD: p = 0.0012). At the group level, a linear discriminant projection of the eight-band profile reaches an ROC-AUC = 0.854. The inter-individual variability of within-subject AFC stability is reduced by a factor of 2.97 in unmedicated ADHD (p = 0.0085) and normalizes under methylphenidate (paired Wilcoxon p = 0.0067, n = 17). The widely used ratio of high- to low-frequency AFC amplitude yields an inflated ROC-AUC of 0.865 on the pre-filtered signal, but only 0.63 on the raw signal. All diagnostic claims are exploratory. The proposed normative feature is simple, interpretable, requires no training set, and can be computed from a single pupil recording.
Related
- Fractional amplitude of low-frequency fluctuations (fALFF) changes in children with anisometropic amblyopia : A resting-state fMRI study
- Prognostic Value of Infarct-Zone Circumferential Strain by CMR Feature Tracking After Acute Myocardial Infarction Treated with Primary PCI
- Bone Marrow Dominant Erdheim-Chester Disease Lacking Characteristic Radiologic Findings: A Diagnostic Pitfall.
- Efficacy Evaluation of Repetitive Transcranial Magnetic Stimulation at Individual Frequency for Patients With Prolonged Disorders of Consciousness: A Preliminary Study Based on Mismatch Negative Amplitude.
- Diagnostic Feature Associations in Atypical Parkinsonian Disorders: A Survey of Movement Disorders Specialists
BibTeX
@article{nikulchev2026amplitudefrequency,
title = {{Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.}},
author = {Evgeny Nikulchev and Alexander N Kosenkov and Andrey Sokolov and Anna Alexeenko and Dmitry Ilin},
journal = {Journal of eye movement research},
year = {2026},
month = oct,
doi = {10.3390/jemr19060124},
url = {https://europepmc.org/article/MED/43081580},
note = {CC BY},
}
RIS
TY - JOUR
TI - Amplitude-Frequency Characteristic as a Novel Eye-Tracking Diagnostic Feature: A Pilot Study on an Open ADHD Dataset.
AU - Evgeny Nikulchev
AU - Alexander N Kosenkov
AU - Andrey Sokolov
AU - Anna Alexeenko
AU - Dmitry Ilin
PY - 2026
DA - 2026/10/30
JO - Journal of eye movement research
DO - 10.3390/jemr19060124
UR - https://europepmc.org/article/MED/43081580
AB - The frequency characteristic of biological systems is a sensitive tool for describing physiological dynamics, yet it has been virtually unused in pupillometry. A novel eye-tracking feature is proposed-the amplitude-frequency characteristic (AFC) of the "stimulus-pupil size" system-and evaluated as a candidate diagnostic marker on an open ADHD dataset. After quality control, 61 sessions (18 controls, 27 unmedicated ADHD, 16 on-medication ADHD) were analyzed. The AFC of the raw diameter signal reveals a systematic elevation of AFC amplitude in ADHD across the 0.5-30 Hz range, strongest in the 20-30 Hz band (Cohen's d = +0.995, p = 0.0034). This is a pilot and methodology- and reproducibility-focused study. At the individual diagnostic level, a normative composite z-score of three bands (10-15, 15-20, 20-30 Hz), computed relative to the control group with fixed weights and no training, reaches an ROC-AUC = 0.788 (Ctrl vs. off-ADHD: p = 0.0012). At the group level, a linear discriminant projection of the eight-band profile reaches an ROC-AUC = 0.854. The inter-individual variability of within-subject AFC stability is reduced by a factor of 2.97 in unmedicated ADHD (p = 0.0085) and normalizes under methylphenidate (paired Wilcoxon p = 0.0067, n = 17). The widely used ratio of high- to low-frequency AFC amplitude yields an inflated ROC-AUC of 0.865 on the pre-filtered signal, but only 0.63 on the raw signal. All diagnostic claims are exploratory. The proposed normative feature is simple, interpretable, requires no training set, and can be computed from a single pupil recording.
SN - 1995-8692
ER -