Skip to content
DraconiticResearch
Search Sources API
197,788 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BYJournal of clinical medicine

Automated Regional Detection of Intervortex Venous Anastomosis on Ultra-Widefield Indocyanine Green Angiography Using a Two-Stage Deep Learning Framework

  1. 1Department of Ophthalmology, College of Medicine, Yeungnam University, Daegu 42415, Republic of Korea
  2. 2Yeungnam Eye Center, Yeungnam University Hospital, Daegu 42415, Republic of Korea

Abstract

Objectives: This study aimed to develop and validate a deep learning–based system for automated detection of intervortex venous anastomosis (IVA) on ultra-widefield indocyanine green angiography (UWF-ICGA). Methods: A total of 183 UWF-ICGA images with an original resolution of 3900 × 3072 pixels were included. A two-stage deep learning framework was developed. In the first stage, an object detection model automatically localized four predefined quadrants within each UWF-ICGA image. In the second stage, each extracted quadrant was classified according to the presence or absence of IVA. Quadrants demonstrating definite venous connections between adjacent vortex vein drainage territories were defined as IVA-positive, whereas quadrants without identifiable intervortex venous connections were defined as IVA-negative. Brightness normalization was applied before analysis, and images were resized to 512 × 512 pixels using linear interpolation. The object detection model was trained using 155 images and tested using 28 images. The 183 original images generated 732 quadrant images, of which 622 were used for training and 110 for testing of the classification model. Model performance was evaluated using accuracy, precision, recall, F1 score, and confusion matrices. Results: The object detection model correctly localized all predefined quadrants in the test dataset, achieving an accuracy, precision, recall, and F1 score of 100.0%. All 112 manually labeled regions from 28 test images were correctly matched by the model. The IVA classification model achieved an accuracy of 93.63%, precision of 95.39%, recall of 91.46%, and F1 score of 93.38%. Among 110 test quadrants, all 69 IVA-negative quadrants were correctly classified, while 34 of 41 IVA-positive quadrants were correctly identified. Seven IVA-positive quadrants were misclassified as negative, whereas no IVA-negative quadrant was classified as positive. When IVA-positive was considered the positive class, the corresponding sensitivity and specificity were 82.9% and 100%, respectively. Conclusions: A two-stage deep learning system enabled automated detection of IVA on UWF-ICGA with high classification performance. Automated assessment of IVA may provide an objective and reproducible approach for evaluating choroidal venous remodeling and may serve as a platform for future quantitative investigations of vortex vein abnormalities.

Related

  1. Automated detection of the CT-angiography spot sign in acute intracerebral hemorrhage
    Dar Dowlatshahi, Dar Dowlatshahi, Santanu Chakraborty +3
    Frontiers in RadiologyPeer-reviewedCC BYFull textNeurologyDOAJ
  2. The Role of Intraoperative Indocyanine Green Fluorescence Angiography in Reducing Anastomotic Leak After Colorectal Resection: A Systematic Review of Randomised Controlled Trials
    Layan Abu-Khalaf, Yahia Khalil, Raya Abu-Khalaf +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Age-Related Hypofluorescent Indocyanine Green Angiography Spots : Prevalence, Characteristics, and Associated Features in Age-Related Macular Degeneration
    Chui Ming Gemmy Cheung, Zehua Jiang, Noa Gilead +3
    Ophthalmology sciencePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. PRISM: Phase-Resolved Isotropic Subtraction Mapping for Automated Multi-Phase CT Digital Subtraction Angiography
    R. Rodriguez, R. Ramirez, H. Rathore
    medRxivPreprintCC BY-NC-NDFull textMedical imaging & radiologymedRxiv
  5. Quantification of plaque and detection of high-risk plaque characteristics based on coronary computed tomography angiography: comparison between superresolution deep learning reconstruction and hybrid iterative reconstruction
    Limiao Zou, Keting Xu, Xiaohuan Liu +26
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
BibTeX
@article{jeong2026automated,
  title = {{Automated Regional Detection of Intervortex Venous Anastomosis on Ultra-Widefield Indocyanine Green Angiography Using a Two-Stage Deep Learning Framework}},
  author = {Areum Jeong and Min Sagong},
  journal = {Journal of clinical medicine},
  year = {2026},
  month = oct,
  doi = {10.3390/jcm15197709},
  url = {https://europepmc.org/article/PMC/PMC13665899},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Automated Regional Detection of Intervortex Venous Anastomosis on Ultra-Widefield Indocyanine Green Angiography Using a Two-Stage Deep Learning Framework
AU  - Areum Jeong
AU  - Min Sagong
PY  - 2026
DA  - 2026/10/01
JO  - Journal of clinical medicine
DO  - 10.3390/jcm15197709
UR  - https://europepmc.org/article/PMC/PMC13665899
AB  - Objectives: This study aimed to develop and validate a deep learning–based system for automated detection of intervortex venous anastomosis (IVA) on ultra-widefield indocyanine green angiography (UWF-ICGA). Methods: A total of 183 UWF-ICGA images with an original resolution of 3900 × 3072 pixels were included. A two-stage deep learning framework was developed. In the first stage, an object detection model automatically localized four predefined quadrants within each UWF-ICGA image. In the second stage, each extracted quadrant was classified according to the presence or absence of IVA. Quadrants demonstrating definite venous connections between adjacent vortex vein drainage territories were defined as IVA-positive, whereas quadrants without identifiable intervortex venous connections were defined as IVA-negative. Brightness normalization was applied before analysis, and images were resized to 512 × 512 pixels using linear interpolation. The object detection model was trained using 155 images and tested using 28 images. The 183 original images generated 732 quadrant images, of which 622 were used for training and 110 for testing of the classification model. Model performance was evaluated using accuracy, precision, recall, F1 score, and confusion matrices. Results: The object detection model correctly localized all predefined quadrants in the test dataset, achieving an accuracy, precision, recall, and F1 score of 100.0%. All 112 manually labeled regions from 28 test images were correctly matched by the model. The IVA classification model achieved an accuracy of 93.63%, precision of 95.39%, recall of 91.46%, and F1 score of 93.38%. Among 110 test quadrants, all 69 IVA-negative quadrants were correctly classified, while 34 of 41 IVA-positive quadrants were correctly identified. Seven IVA-positive quadrants were misclassified as negative, whereas no IVA-negative quadrant was classified as positive. When IVA-positive was considered the positive class, the corresponding sensitivity and specificity were 82.9% and 100%, respectively. Conclusions: A two-stage deep learning system enabled automated detection of IVA on UWF-ICGA with high classification performance. Automated assessment of IVA may provide an objective and reproducible approach for evaluating choroidal venous remodeling and may serve as a platform for future quantitative investigations of vortex vein abnormalities.
SN  - 2077-0383
ER  -