Abstract

Purpose Conventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry. Methods In this Institutional Review Board–approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error. Results The model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of −3.96±48.44 mL, with limits of agreement from −98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0–100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture. Conclusion A deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.

Related

  1. Sagittal Long-Axis Bladder Diameter and CT-Measured Bladder Wall Thickness in Healthy Female Patients.
    Gavin L Feinberg, Celine Torkzad, Martha K Terris +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Acceptability, feasibility, quality of life and diabetes distress score outcomes: A pragmatic randomised clinical trial on continuous glucose monitoring for people with type 1 diabetes
    E. Marban-Castro, L. Muhwava, S. Girdwood +17
    medRxivPreprintCC BYFull textEndocrinology & metabolismmedRxiv
  3. Usability, acceptability and feasibility of continuous glucose monitoring among children and adolescents with type 1 diabetes in Kenya
    P. Amolo, L. Mungai, A. K. Karume +6
    medRxivPreprintCC BY-NCFull textEndocrinology & metabolismmedRxiv
  4. Localization-Aware Multiscale Deep Learning for Lumbar Foraminal Stenosis in Multi-Scanner Sagittal MRI: A Leakage-Controlled Evaluation
    Y. Riyazifar
    medRxivPreprintAll rights reservedFull textMedical imaging & radiologymedRxiv
  5. 124 Integrated single-cell transcriptomic profiling of urine-derived cells as a strategy for non-invasive therapeutic monitoring in bladder cancer
    John Sfakianos, Amir Horowitz, Chong Li +16
    Journal for ImmunoTherapy of CancerPeer-reviewedCC BYSurgery & anaesthesiaDOAJ
BibTeX
@article{kwon2026singlesagittalplane,
  title = {{A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study}},
  author = {Junhwan Kwon and Ilseob Song and Sangeun Park and Jongsoo Lee and Yangmo Yoo},
  journal = {Ultrasonography},
  year = {2026},
  month = jul,
  doi = {10.14366/usg.25258},
  url = {https://doi.org/10.14366/usg.25258},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study
AU  - Junhwan Kwon
AU  - Ilseob Song
AU  - Sangeun Park
AU  - Jongsoo Lee
AU  - Yangmo Yoo
PY  - 2026
DA  - 2026/07/01
JO  - Ultrasonography
DO  - 10.14366/usg.25258
UR  - https://doi.org/10.14366/usg.25258
AB  - Purpose Conventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry. Methods In this Institutional Review Board–approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error. Results The model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of −3.96±48.44 mL, with limits of agreement from −98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0–100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture. Conclusion A deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.
SN  - 2288-5943
SN  - 2288-5919
ER  -