Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 39 min ago
Peer-reviewedCC BYJournal of health economics and outcomes research

Health Economic Outcomes of Subacromial Balloon Spacer Implantation Across Surgical Care Pathways: A Propensity-Matched Analysis of German Statutory Insurance Claims

6 affiliations
  1. 1Stryker, Endoscopy Europe, Freiburg, Germany.
  2. 2Stryker GmbH & Co. KG, Duisburg, Germany.
  3. 3Inspiring-Health GmbH, Munich, Germany.
  4. 4WIG2 GmbH - Scientific Institute for Health Economics and Health System Research, Leipzig, Germany.
  5. 5Ostsee Klinik, Bad Schwartau, Germany.
  6. 6Gelenkchirurgie Orthopädie, Hannover, Germany.

Abstract

Background

Massive irreparable rotator cuff tears are managed along a surgical spectrum from arthroscopic debridement to reverse shoulder arthroplasty (RSA). The biodegradable subacromial balloon spacer is a minimally invasive option with limited real-world payer-perspective comparative evidence.Objectives

To quantify postoperative complications, payer reimbursement, and care-pathway utilization for balloon spacer implantation vs four surgical alternatives in routine statutory health insurance (SHI) practice.Methods

Retrospective propensity-score-matched cohort analysis of anonymized claims from a German SHI database (~4.5 million insured). Adults treated surgically for rotator cuff pathology (ICD-10-GM M75.1) between 2017 and 2020 were included. Balloon spacer patients (n = 99) were matched 1:2 on propensity scores against RSA, open repair, arthroscopic repair, and debridement. Primary outcomes were 12- and 24-month complication rates and index hospitalization costs; secondary outcomes were shoulder-related sick leave and time to first physiotherapy.Results

Balloon spacer hospitalization costs (€3502) were 65% lower than RSA (€9969) and modestly lower than open repair (€3829); arthroscopic repair (€3245) and debridement (€2464) were less expensive. Twelve-month complications were lower than RSA (1.3% vs 12.2%) and comparable to other comparators. Physiotherapy began earlier after balloon spacer (11.4 days) than RSA (27.6), open repair (20.0), or arthroscopic repair (18.1). In a small exploratory subgroup aged 60 to 64 years (n = 15 to 19 balloon spacer patients per comparison), sick leave duration and indirect costs were directionally lower for the balloon spacer, but these estimates are hypothesis-generating only. The balloon spacer occupied a cost-efficient position in the surgical care pathway, and the cost gap vs RSA was robust in an inpatient-only sensitivity analysis. Residual confounding by indication cannot be excluded.Conclusions

Within a large German SHI dataset, balloon spacer implantation was associated with substantially lower direct hospitalization costs than RSA, comparable safety to less invasive alternatives, and earlier physiotherapy initiation. A subgroup signal of reduced indirect costs in working-age patients rested on very small samples and should be regarded as hypothesis-generating rather than as input for payer policy modeling. These findings support the device as a de-escalation option for appropriately selected patients in payer systems facing rising arthroplasty utilization.

Related

  1. Economic Burden of Post-COVID Syndrome in Germany Between 2021 and 2025: A Statutory Health Insurance Claims Data Analysis.
    Daniel Gensorowsky, Emma Fröling, Kylie Braegelmann +6
    Journal of health economics and outcomes researchPeer-reviewedCC BYFull textNeurologyEurope PMC
  2. Ultrasound-guided peripheral regional anesthesia vs local infiltration anesthesia for cardiac device implantation: A propensity score–matched prospective observational cohort study
    Riyong Zhou, Ziyi Ni, Yaoxue Zang +8
    Heart rhythm O2Peer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Health insurance coverage and quality of care for reproductive and maternal health in LMICs: a multicountry propensity score matching study
    Tiara Marthias, Kanya Anindya, Barbara McPake +8
    BMJ Global HealthPeer-reviewedCC BY-NC 4.0Full textObstetrics, gynaecology & paediatricsPMC
  4. Economic Value and Caregiver Burden of Continuous Fascia iliaca Compartment Block in Elderly Patients with Intertrochanteric or Subtrochanteric Fracture: A Cost-Consequence Analysis Based on a Propensity Score-Matched Cohort.
    Zijian Wang, Hua Gao, Guoqiang Xu +2
    ClinicoEconomics and outcomes research : CEORPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMC
  5. Diagnostic Musculoskeletal Ultrasound in the Evaluation of the Subacromial Bursa
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{harms2026health,
  title = {{Health Economic Outcomes of Subacromial Balloon Spacer Implantation Across Surgical Care Pathways: A Propensity-Matched Analysis of German Statutory Insurance Claims}},
  author = {Marc Harms and Christoph Pross and Harald Kuhlmann and Tarcyane Barata Garcia and Jan Eßer and Jens Agneskirchner},
  journal = {Journal of health economics and outcomes research},
  year = {2026},
  month = sep,
  doi = {10.36469/001c.164920},
  url = {https://europepmc.org/article/PMC/PMC13727280},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Health Economic Outcomes of Subacromial Balloon Spacer Implantation Across Surgical Care Pathways: A Propensity-Matched Analysis of German Statutory Insurance Claims
AU  - Marc Harms
AU  - Christoph Pross
AU  - Harald Kuhlmann
AU  - Tarcyane Barata Garcia
AU  - Jan Eßer
AU  - Jens Agneskirchner
PY  - 2026
DA  - 2026/09/23
JO  - Journal of health economics and outcomes research
DO  - 10.36469/001c.164920
UR  - https://europepmc.org/article/PMC/PMC13727280
AB  - Background  Massive irreparable rotator cuff tears are managed along a surgical spectrum from arthroscopic debridement to reverse shoulder arthroplasty (RSA). The biodegradable subacromial balloon spacer is a minimally invasive option with limited real-world payer-perspective comparative evidence.Objectives  To quantify postoperative complications, payer reimbursement, and care-pathway utilization for balloon spacer implantation vs four surgical alternatives in routine statutory health insurance (SHI) practice.Methods  Retrospective propensity-score-matched cohort analysis of anonymized claims from a German SHI database (~4.5 million insured). Adults treated surgically for rotator cuff pathology (ICD-10-GM M75.1) between 2017 and 2020 were included. Balloon spacer patients (n = 99) were matched 1:2 on propensity scores against RSA, open repair, arthroscopic repair, and debridement. Primary outcomes were 12- and 24-month complication rates and index hospitalization costs; secondary outcomes were shoulder-related sick leave and time to first physiotherapy.Results  Balloon spacer hospitalization costs (€3502) were 65% lower than RSA (€9969) and modestly lower than open repair (€3829); arthroscopic repair (€3245) and debridement (€2464) were less expensive. Twelve-month complications were lower than RSA (1.3% vs 12.2%) and comparable to other comparators. Physiotherapy began earlier after balloon spacer (11.4 days) than RSA (27.6), open repair (20.0), or arthroscopic repair (18.1). In a small exploratory subgroup aged 60 to 64 years (n = 15 to 19 balloon spacer patients per comparison), sick leave duration and indirect costs were directionally lower for the balloon spacer, but these estimates are hypothesis-generating only. The balloon spacer occupied a cost-efficient position in the surgical care pathway, and the cost gap vs RSA was robust in an inpatient-only sensitivity analysis. Residual confounding by indication cannot be excluded.Conclusions  Within a large German SHI dataset, balloon spacer implantation was associated with substantially lower direct hospitalization costs than RSA, comparable safety to less invasive alternatives, and earlier physiotherapy initiation. A subgroup signal of reduced indirect costs in working-age patients rested on very small samples and should be regarded as hypothesis-generating rather than as input for payer policy modeling. These findings support the device as a de-escalation option for appropriately selected patients in payer systems facing rising arthroplasty utilization.
SN  - 2326-697X
SN  - 2327-2236
ER  -