Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 34 min ago
PreprintarXiv licencearXiv

A low-cost compact muon detector for millikelvin operation

Abstract

Ionizing radiation produces correlated errors in superconducting qubits, posing some challenges to quantum error correction. In addition, it causes background events in other superconducting cryogenic devices, such as kinetic inductance detectors and superconducting nanowire single-photon detectors. Cosmic muons are a component of this background that can only be partly shielded against at ground level, but can be tagged by an independent detector inside the cryostat, so that the affected data can be vetoed, or the muon tags incorporated into error correction. We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence. We characterize the SiPMs from room temperature down to 10 mK, including the breakdown and upper-limit voltages that define the operating bias range. Operated as a muon counter, the detector measures a coincidence rate that, as expected, is independent of temperature within uncertainties and agrees with analytical and Monte Carlo predictions. Below approximately 8 K, each muon event produces two pulses, one narrow and one broad, an effect that, to our knowledge, has not been reported before. Coincidences with an independent muon detector outside the cryostat confirm that muons are still counted reliably in this regime. By studying the appearance of double pulses as a function of temperature and magnetic field up to 4.5 T, we find a behavior consistent with the phase diagram of a type-II superconductor. This links the double pulses to a superconducting material in the SiPM, likely an adhesion layer or diffusion barrier introduced during manufacturing. The mechanism by which the superconducting state produces the second pulse is not yet understood.

Related

  1. The CosmicWatch Desktop Muon Detector (v3X): Prototype Design and Adaptation for Spaceflight
    Anvay Ajmera, Spencer N. G. Axani
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  2. Continuous-wave operation of a compact 1550-nm Si/InP heterogeneously integrated photonic-crystal surface-emitting laser
    Kangjiang Yang, Xiaoyu Zhang, zixuan zhang +11
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Charge-dependent atmospheric muon flux at 17 GV geomagnetic cutoff with the mini-ICAL detector
    S. Pethuraj, Raj Shah, G. Majumder +1
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsarXiv
  4. Muon Bulb: A Cosmic-Ray Detector Inside a Light Bulb
    Yuvaraj Elangovan
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  5. Muon Detection and Direction Reconstruction with the Upgraded 1-ton Water Cherenkov Prototype Detector at CJPL-I
    Yapeng Wang, Yuzi Yang, Shaomin Chen +35
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
BibTeX
@misc{ibrayev2026lowcost,
  title = {{A low-cost compact muon detector for millikelvin operation}},
  author = {Tengiz Ibrayev and Danish Khan and Alex Herscovics and Komal Kataruka and Matilda Lawton and Sandhya Sharma and Steven Waddy and Laura Manenti},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.20132},
  eprint = {2610.20132},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.20132},
}
RIS
TY  - UNPB
TI  - A low-cost compact muon detector for millikelvin operation
AU  - Tengiz Ibrayev
AU  - Danish Khan
AU  - Alex Herscovics
AU  - Komal Kataruka
AU  - Matilda Lawton
AU  - Sandhya Sharma
AU  - Steven Waddy
AU  - Laura Manenti
PY  - 2026
DA  - 2026/10/14
PB  - arXiv
DO  - 10.48550/arxiv.2610.20132
UR  - https://arxiv.org/abs/2610.20132
AB  - Ionizing radiation produces correlated errors in superconducting qubits, posing some challenges to quantum error correction. In addition, it causes background events in other superconducting cryogenic devices, such as kinetic inductance detectors and superconducting nanowire single-photon detectors. Cosmic muons are a component of this background that can only be partly shielded against at ground level, but can be tagged by an independent detector inside the cryostat, so that the affected data can be vetoed, or the muon tags incorporated into error correction. We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence. We characterize the SiPMs from room temperature down to 10 mK, including the breakdown and upper-limit voltages that define the operating bias range. Operated as a muon counter, the detector measures a coincidence rate that, as expected, is independent of temperature within uncertainties and agrees with analytical and Monte Carlo predictions. Below approximately 8 K, each muon event produces two pulses, one narrow and one broad, an effect that, to our knowledge, has not been reported before. Coincidences with an independent muon detector outside the cryostat confirm that muons are still counted reliably in this regime. By studying the appearance of double pulses as a function of temperature and magnetic field up to 4.5 T, we find a behavior consistent with the phase diagram of a type-II superconductor. This links the double pulses to a superconducting material in the SiPM, likely an adhesion layer or diffusion barrier introduced during manufacturing. The mechanism by which the superconducting state produces the second pulse is not yet understood.
ER  -