Technical Performance and Automated-manual Scoring Agreement in Type III Home Sleep Apnea Testing: A Single-center Study from Saudi Arabia.
6 affiliations
- 1Department of Medicine, College of Medicine, Najran University, Najran, Saudi Arabia.
- 2Sleep Medicine Department, King Saud University Medical City, Riyadh, Saudi Arabia.
- 3Department of Medicine, College of Medicine, University Sleep Disorders Center, King Saud University, Riyadh, Saudi Arabia.
- 4Department of Medicine, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
- 5Family and Community Medicine, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
- 6The Strategic Technologies Program of the National Plan for Sciences and Technology and Innovation in the Kingdom of Saudi Arabia, Riyadh, Saudi Arabia.
Abstract
Background
Obstructive sleep apnea (OSA) is a prevalent disorder that carries significant health risks. Home sleep apnea testing (HSAT) is a cost-effective alternative to in-lab polysomnography for diagnosing OSA.Objectives
To evaluate the technical performance and automated-manual scoring agreement of type III HSAT in a Saudi population with a high pretest probability of OSA, and to establish a local performance baseline that can inform future multicenter and cross-regional comparisons.Methods
This retrospective study included adults with a high pretest probability of moderate-severe OSA who underwent type III HSAT at a tertiary sleep center in Riyadh, Saudi Arabia. Automated HSAT recordings (Nox T3 device) were re-scored manually by a blinded sleep technologist. Key outcomes included technical success and agreement between automated and manual scoring of respiratory indices.Results
A total of 173 participants were included, of which 128 (74.4%) had OSA. HSAT was technically successful in 90.7% of cases. Automated apnea-hypopnea index demonstrated high overall concordance with manual scoring (CCC = 0.919; 95% CI: 0.893-0.940), with minimal mean bias. The apnea index (CCC = 0.993; 95% CI: 0.990-0.995) and oxygen desaturation index (CCC = 0.973; 95% CI: 0.964-0.980) demonstrated excellent concordance, while the hypopnea index showed moderate concordance (CCC = 0.820; 95% CI: 0.764-0.864) with modest automated underestimation. In technically failed cases, nasal airflow showed the poorest signal quality (mean ± SD, 58.4% ± 27.4%) followed by pulse oximetry (86.7% ± 25.1%).Conclusion
Among adults from Saudi Arabia, type III HSAT had a high technical success rate and strong overall agreement between automated and manual scoring. These findings support the use of HSAT as a reliable diagnostic alternative in appropriately selected adults with a high pretest probability of OSA.
Related
- Analytical Agreement and Diagnostic Performance of a Commercial Point-of-Care Lipid Testing System for Lipid Profile and Atherogenic Ratios
- Camera-Based AI-Assisted Scoring for the Balance Error Scoring System: A Cross-sectional Validity and Agreement Study
- Interobserver agreement of non-parallel transmission technology zoomed-diffusion-weighted imaging (DWI) for ordinal biparametric Vesical Imaging-Reporting and Data System (VI-RADS)-based scoring in bladder cancer lesions ≥1 cm
- How much of the incremental protocol does a lactate threshold need? Agreement between three-stage and five-stage testing across seven lactate-derived indices in swimmers
- Model evaluation for automated scoring of electropenetrography waveform data from mosquitoes
BibTeX
@article{aldhabei2026technical,
title = {{Technical Performance and Automated-manual Scoring Agreement in Type III Home Sleep Apnea Testing: A Single-center Study from Saudi Arabia.}},
author = {Sultan Aldhabei and Raghad Alhajaji and Salih A Aleissi and Hamza O Dhafar and Samar Z Nashwan and Mohammad Alrashed and Abdullah Aldhuwaihy and Talal Alghadir and Mohammed H Alhumud and Ahmed T Alhawamdeh and Ahmed S Bahammam},
journal = {Saudi journal of medicine \& medical sciences},
year = {2026},
month = oct,
doi = {10.4103/sjmms.sjmms_100_26},
url = {https://europepmc.org/article/MED/42974588},
note = {CC BY-NC-SA},
}
RIS
TY - JOUR
TI - Technical Performance and Automated-manual Scoring Agreement in Type III Home Sleep Apnea Testing: A Single-center Study from Saudi Arabia.
AU - Sultan Aldhabei
AU - Raghad Alhajaji
AU - Salih A Aleissi
AU - Hamza O Dhafar
AU - Samar Z Nashwan
AU - Mohammad Alrashed
AU - Abdullah Aldhuwaihy
AU - Talal Alghadir
AU - Mohammed H Alhumud
AU - Ahmed T Alhawamdeh
AU - Ahmed S Bahammam
PY - 2026
DA - 2026/10/14
JO - Saudi journal of medicine & medical sciences
DO - 10.4103/sjmms.sjmms_100_26
UR - https://europepmc.org/article/MED/42974588
AB - Background Obstructive sleep apnea (OSA) is a prevalent disorder that carries significant health risks. Home sleep apnea testing (HSAT) is a cost-effective alternative to in-lab polysomnography for diagnosing OSA.Objectives To evaluate the technical performance and automated-manual scoring agreement of type III HSAT in a Saudi population with a high pretest probability of OSA, and to establish a local performance baseline that can inform future multicenter and cross-regional comparisons.Methods This retrospective study included adults with a high pretest probability of moderate-severe OSA who underwent type III HSAT at a tertiary sleep center in Riyadh, Saudi Arabia. Automated HSAT recordings (Nox T3 device) were re-scored manually by a blinded sleep technologist. Key outcomes included technical success and agreement between automated and manual scoring of respiratory indices.Results A total of 173 participants were included, of which 128 (74.4%) had OSA. HSAT was technically successful in 90.7% of cases. Automated apnea-hypopnea index demonstrated high overall concordance with manual scoring (CCC = 0.919; 95% CI: 0.893-0.940), with minimal mean bias. The apnea index (CCC = 0.993; 95% CI: 0.990-0.995) and oxygen desaturation index (CCC = 0.973; 95% CI: 0.964-0.980) demonstrated excellent concordance, while the hypopnea index showed moderate concordance (CCC = 0.820; 95% CI: 0.764-0.864) with modest automated underestimation. In technically failed cases, nasal airflow showed the poorest signal quality (mean ± SD, 58.4% ± 27.4%) followed by pulse oximetry (86.7% ± 25.1%).Conclusion Among adults from Saudi Arabia, type III HSAT had a high technical success rate and strong overall agreement between automated and manual scoring. These findings support the use of HSAT as a reliable diagnostic alternative in appropriately selected adults with a high pretest probability of OSA.
SN - 1658-631X
SN - 2321-4856
ER -