Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 33 min ago
Peer-reviewedCC BY 4.0Diagnostics

Corneal Biomechanical and Tomographic Signatures for Keratoconus

5 affiliations
  1. 1Medical Informatics and Biostatistics, Department 11—Medical Education, Faculty of Medicine, “Iuliu Hațieganu” University of Medicine and Pharmacy, Louis Pasteur Str., No. 6, 400349 Cluj-Napoca, Romania
  2. 2Oculens Clinic, Calea Turzii, No. 134, 400347 Cluj-Napoca, Romania; (C.A.N.)
  3. 3Medical Specialties, Department 1—Maxillo-Facial Surgery and Radiology, Faculty of Dental Medicine, “Iuliu Hațieganu” University of Medicine and Pharmacy, Victor Babeş Str., No. 2–4, 400012 Cluj-Napoca, Romania
  4. 4Pathophysiology, Department 1—Morpho-Functional Sciences, Faculty of Medicine, “Iuliu Hațieganu” University of Medicine and Pharmacy, Victor Babeş Str., No. 2–4, 400012 Cluj-Napoca, Romania
  5. 5Ophthalmology, Department 12—Ophthalmology and Otorhinolaryngology (ENT), Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, Boulevard Eroii Sanitari No. 8, Sector 5, 050474 Bucharest, Romania

Abstract

Objectives: This study aimed to identify tomographic and biomechanical biomarkers that differentiate mild/moderate from advanced/severe keratoconus (KCN) based on the ABCD classification. The secondary objective was to assess the diagnostic performance of previously reported biomarkers for distinguishing KCN from KCN-free controls and to compare classifications derived from cohort-specific and previously established cutoff values, evaluating their consistency and potential generalizability in the Romanian KCN population. Methods: Adult patients who presented to the Oculens Clinic between 1 January 2024 and 1 September 2025 for clinical care were eligible for enrolment in this observational study. Diagnosis of KCN was made following current practice, and all participants underwent ophthalmologic examination followed by corneal tomography and biomechanical measurements. Results: Forty-four subjects with KCN and 38 controls, with a median age of 26.5 years. Patients with mild/moderate KCN (23 patients) were similar in terms of age and sex to those with advanced/severe KCN (21 patients). The values of Kmax showed the best performance in terms of AUC (0.908, 95%CI = [0.824 to 0.992], Se = 76.19 [52.83 to 91.78], Sp = 86.96 [66.41 to 97.22], cutoff = 54.15), with an excellent discriminatory ability in the identification of patients with mild/moderate KCN compared to advanced/severe KCN. Low TL values indicate advanced/severe disease, with the highest values of true positives (18), true negatives (22), and the smallest value of false negatives (3) but with a moderate AUC (0.880 [0.755 to 1.0]). The performances of previously reported cutoff values on the Romanian cohort were tested in 44 patients with KCN and 38 KCN-free individuals. The discriminatory abilities of the previously reported indices, except for KI and BAD-D which were overfitted, were retained in the current cohort, and all exhibited excellent (AUC lower bounds higher than 0.9) or good (AUC lower bounds higher than 0.8) discriminatory performances. The agreement between the current cutoff values and the classification generated by the previously reported cutoff values is sustained by almost perfect agreement in the classification as KCN or KCN-free (Cohen’s kappa values ≥ 0.81, and raw agreement ≥ 90%). Conclusions: Our findings support further evaluation of Kmax and corneal thinnest location as markers of keratoconus severity and as potential tools for disease detection. The high concordance observed between classification based on cohort-specific and previously established thresholds suggests consistent performance of these biomarkers within the study population. These parameters may represent promising tools for the management of patients with keratoconus, pending further validation.

Related

  1. Diagnostic Performance of Integrated Tomographic–Biomechanical Indices Across Keratoconus Stages in a Chinese Population
    Peipei Zhang, Xinyu Zhang, Ruizheng Gu +7
    Translational Vision Science & TechnologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Review of preoperative tomographic and biomechanical corneal assessment for refractive surgery
    Elizabeth Wen Ling Lim, Li Lim
    Taiwan Journal of OphthalmologyPeer-reviewedCC BY-NC-NDFull text2 citedMedical imaging & radiologyDOAJ
  3. Beyond Epithelial Thickness: Comprehensive Profiling of Corneal Epithelial Remodeling and Its Diagnostic Value Across Keratoconus Severity: The Noor Multimodal Corneal Imaging Study (NMCIS)
    Hassan Hashemi, Mehrnaz Atighehchian, Alireza Hashemi +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Extragonadal role of FSH in regulating corneal homeostasis in Keratoconus
    Amit Chatterjee, Levi N. Kanu, Amy E. Ross +7
    Communications BiologyPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCrossref
  5. Integrating corneal endophenotypes with classic GWAS approaches identifies novel keratoconus loci
    Hasan Shabani, Gregor Buch, Samantha S. Y. Lee +27
    Communications BiologyPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCrossref
BibTeX
@article{nicula2026corneal,
  title = {{Corneal Biomechanical and Tomographic Signatures for Keratoconus}},
  author = {Ariadna Patricia Nicula and Cristina Ariadna Nicula and Dorin Nicula and Adriana Elena Bulboacă and Valeria Coviltir and Sorana D. Bolboacă},
  journal = {Diagnostics},
  year = {2026},
  month = oct,
  doi = {10.3390/diagnostics16213506},
  url = {https://doi.org/10.3390/diagnostics16213506},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Corneal Biomechanical and Tomographic Signatures for Keratoconus
AU  - Ariadna Patricia Nicula
AU  - Cristina Ariadna Nicula
AU  - Dorin Nicula
AU  - Adriana Elena Bulboacă
AU  - Valeria Coviltir
AU  - Sorana D. Bolboacă
PY  - 2026
DA  - 2026/10/26
JO  - Diagnostics
DO  - 10.3390/diagnostics16213506
UR  - https://doi.org/10.3390/diagnostics16213506
AB  - Objectives: This study aimed to identify tomographic and biomechanical biomarkers that differentiate mild/moderate from advanced/severe keratoconus (KCN) based on the ABCD classification. The secondary objective was to assess the diagnostic performance of previously reported biomarkers for distinguishing KCN from KCN-free controls and to compare classifications derived from cohort-specific and previously established cutoff values, evaluating their consistency and potential generalizability in the Romanian KCN population. Methods: Adult patients who presented to the Oculens Clinic between 1 January 2024 and 1 September 2025 for clinical care were eligible for enrolment in this observational study. Diagnosis of KCN was made following current practice, and all participants underwent ophthalmologic examination followed by corneal tomography and biomechanical measurements. Results: Forty-four subjects with KCN and 38 controls, with a median age of 26.5 years. Patients with mild/moderate KCN (23 patients) were similar in terms of age and sex to those with advanced/severe KCN (21 patients). The values of Kmax showed the best performance in terms of AUC (0.908, 95%CI = [0.824 to 0.992], Se = 76.19 [52.83 to 91.78], Sp = 86.96 [66.41 to 97.22], cutoff = 54.15), with an excellent discriminatory ability in the identification of patients with mild/moderate KCN compared to advanced/severe KCN. Low TL values indicate advanced/severe disease, with the highest values of true positives (18), true negatives (22), and the smallest value of false negatives (3) but with a moderate AUC (0.880 [0.755 to 1.0]). The performances of previously reported cutoff values on the Romanian cohort were tested in 44 patients with KCN and 38 KCN-free individuals. The discriminatory abilities of the previously reported indices, except for KI and BAD-D which were overfitted, were retained in the current cohort, and all exhibited excellent (AUC lower bounds higher than 0.9) or good (AUC lower bounds higher than 0.8) discriminatory performances. The agreement between the current cutoff values and the classification generated by the previously reported cutoff values is sustained by almost perfect agreement in the classification as KCN or KCN-free (Cohen’s kappa values ≥ 0.81, and raw agreement ≥ 90%). Conclusions: Our findings support further evaluation of Kmax and corneal thinnest location as markers of keratoconus severity and as potential tools for disease detection. The high concordance observed between classification based on cohort-specific and previously established thresholds suggests consistent performance of these biomarkers within the study population. These parameters may represent promising tools for the management of patients with keratoconus, pending further validation.
SN  - 2075-4418
ER  -