Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 50 min ago
PreprintCC BY-NC-NDmedRxiv

Dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (dual-wavelength TOF-iSCOS) for co-registered blood-flow and hemoglobin sensing

  1. 1Institute of Physical Chemistry PAS

Abstract

Diffuse optical measurements of blood flow, blood volume, and blood oxygenation often use separate devices and photon populations. Combining these contrasts within a common photon population would enable their direct co-registration while retaining time-of-flight-based depth discrimination. We introduce dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (TOF-iSCOS), built on an interferometric near-infrared spectroscopy (iNIRS) architecture that temporally multiplexes 780 and 852 nm swept lasers through a shared detection channel. It recovers co-registered flow-sensitive field dynamics and wavelength-resolved attenuation from the same complex-field acquisition. Three 50 ps TOF gates sample increasingly late-arriving photons. Within each gate, g1 was calculated directly as the normalized temporal autocorrelation of the reconstructed complex field.{kappa} 2(T) was reconstructed by finite-time integration of measured g1 and finite-integration fits yielded decorrelation rates. No camera speckle-variance contrast or Siegert substitution was used. Gate-integrated TPSF intensities yielded optical-density changes{Delta} OD, and division by the baseline-TPSF-weighted mean photon path length gave effective{Delta} {micro}a for two-wavelength hemoglobin inversion. In 12 forearm cuff-occlusion recordings from 11 adults, TOF-iSCOS detected flow suppression during occlusion and reactive hyperemia after release at both wavelengths. At 780 nm, the Late-minus-Early reactive-hyperemia amplitude in the relative blood-flow index (rBFI) was +0.647 (95% CI 0.194 to 1.124), whereas the Early-minus-Late cuff{Delta} {micro}a contrast was +0.196 cm-1 (95% CI 0.123 to 0.280). In the photon-limited 852 nm Late gate, the accepted-frame fraction was 0.994 for{kappa} 2-based fitting versus 0.831 for g1-based fitting. Exploratory phase-resolved analysis suggested that the initial hemoglobin response was concentrated in early-arriving photons, while later responses differed in magnitude and direction. Wavelength, field dynamics, and photon time-of-flight thus provide complementary physiological information; the largest response need not identify the phase of interest.

Related

  1. Error in Hemoglobin Concentration
    JAMA Network OpenPeer-reviewedCC BY 4.0General medicineCrossref
  2. Prognostic value of the hemoglobin, albumin, lymphocyte, and platelet score in nonmetastatic renal cell carcinoma after nephrectomy
    Zheng Huang, Dan Chen
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Increased mean corpuscular hemoglobin concentration : A case report as an early clue of chronic severe hyponatremia
    Jianping Chen, Shi Chen, Xinzheng Li +2
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Human hemoglobin protects the parasite cytoskeleton during Plasmodium falciparum gametocyte development
    Xu Wang, Jianwei Zeng, Pengge Qian +3
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
  5. Hemoglobin glycation index and the dynamic progression of cardiometabolic multimorbidity and mortality: a multi-state Markov analysis
    Chang Liu, Wenkai Zhu, Yuzhen Jiang +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
BibTeX
@misc{nowackapieszak2026dualwavelength,
  title = {{Dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (dual-wavelength TOF-iSCOS) for co-registered blood-flow and hemoglobin sensing}},
  author = {K. Nowacka-Pieszak and M. Marzejon and N. Mogharari and D. Borycki},
  howpublished = {medRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.02.26362024},
  url = {https://www.medrxiv.org/content/10.64898/2026.09.02.26362024v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (dual-wavelength TOF-iSCOS) for co-registered blood-flow and hemoglobin sensing
AU  - K. Nowacka-Pieszak
AU  - M. Marzejon
AU  - N. Mogharari
AU  - D. Borycki
PY  - 2026
DA  - 2026/09/02
PB  - medRxiv
DO  - 10.64898/2026.09.02.26362024
UR  - https://www.medrxiv.org/content/10.64898/2026.09.02.26362024v1
AB  - Diffuse optical measurements of blood flow, blood volume, and blood oxygenation often use separate devices and photon populations. Combining these contrasts within a common photon population would enable their direct co-registration while retaining time-of-flight-based depth discrimination. We introduce dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (TOF-iSCOS), built on an interferometric near-infrared spectroscopy (iNIRS) architecture that temporally multiplexes 780 and 852 nm swept lasers through a shared detection channel. It recovers co-registered flow-sensitive field dynamics and wavelength-resolved attenuation from the same complex-field acquisition. Three 50 ps TOF gates sample increasingly late-arriving photons. Within each gate, g1 was calculated directly as the normalized temporal autocorrelation of the reconstructed complex field.{kappa} 2(T) was reconstructed by finite-time integration of measured g1 and finite-integration fits yielded decorrelation rates. No camera speckle-variance contrast or Siegert substitution was used. Gate-integrated TPSF intensities yielded optical-density changes{Delta} OD, and division by the baseline-TPSF-weighted mean photon path length gave effective{Delta} {micro}a for two-wavelength hemoglobin inversion. In 12 forearm cuff-occlusion recordings from 11 adults, TOF-iSCOS detected flow suppression during occlusion and reactive hyperemia after release at both wavelengths. At 780 nm, the Late-minus-Early reactive-hyperemia amplitude in the relative blood-flow index (rBFI) was +0.647 (95% CI 0.194 to 1.124), whereas the Early-minus-Late cuff{Delta} {micro}a contrast was +0.196 cm-1 (95% CI 0.123 to 0.280). In the photon-limited 852 nm Late gate, the accepted-frame fraction was 0.994 for{kappa} 2-based fitting versus 0.831 for g1-based fitting. Exploratory phase-resolved analysis suggested that the initial hemoglobin response was concentrated in early-arriving photons, while later responses differed in magnitude and direction. Wavelength, field dynamics, and photon time-of-flight thus provide complementary physiological information; the largest response need not identify the phase of interest.
ER  -