Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 29 min ago
Peer-reviewedCC BYCureus

Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.

5 affiliations
  1. 1Emergency, Broomfield Hospital, Chelmsford, GBR.
  2. 2Radiology, Broomfield Hospital, Chelmsford, GBR.
  3. 3Intensive Care Unit, Broomfield Hospital, Chelmsford, GBR.
  4. 4Radiology, Southend University Hospital NHS Foundation Trust, Southend-on-Sea, GBR.
  5. 5Medical Education, Peterborough City Hospital, Peterborough, GBR.

Abstract

Scaphoid fractures are the most common carpal bone fracture. Non-union and avascular necrosis are complications of a missed fracture. Therefore, if plain radiographs are normal and symptoms persist, further imaging such as computed tomography (CT) or magnetic resonance imaging (MRI) are often performed. Previous systematic reviews have largely compared their diagnostic accuracy indirectly using separate patient cohorts. Our objective is to determine the diagnostic accuracy of CT for occult scaphoid fractures in patients who underwent both CT and MRI following a negative or equivocal initial radiograph, and to assess concordance between CT and MRI findings. A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. OVID MEDLINE, OVID Embase, and the Cochrane Library were searched for studies published from inception up to August 31, 2026. Eligible studies enrolled adults with clinically suspected scaphoid fracture and a negative or equivocal initial radiograph who subsequently underwent both CT and MRI. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Studies affected by partial verification or incorporation bias were excluded from quantitative synthesis. CT sensitivity and specificity were pooled using a bivariate random-effects model. Concordance between CT and MRI was reported using percentage agreement and Cohen's kappa. Eight studies met the inclusion criteria. Six studies contributed to the primary pooled analysis of CT diagnostic accuracy, with one study reporting two CT readers. Using the first reader data from that study, alongside the five other studies, pooled CT sensitivity was 79% (95% CI 61.5-89.8%) and specificity was 94.4% (95% CI 82.1-98.4%). A sensitivity analysis using the second reader produced a sensitivity of 69.2% (95% CI 48.0-84.6%), with an unchanged specificity of 94.4% (95% CI 85.5-98.0%). Three studies provided CT-MRI concordance data; two demonstrated almost perfect agreement, with Cohen's kappa values of 0.91. The dual-energy CT study demonstrated lower concordance. Three studies used a reference standard independent of both CT and MRI and demonstrated mixed comparative findings. Overall, one study was judged to have low risk of bias, and seven were high risk of bias. In the included studies, CT demonstrated high specificity but more limited sensitivity for occult scaphoid fracture in paired CT-MRI cohorts. These findings align with existing literature reviewing unpaired data sets. Therefore, the findings suggest that CT remains a relevant alternative to MRI, especially in centres where MRI is unavailable or contraindicated, or for surgical planning.

Related

  1. Age- and Site-Specific Ecological Concordance Between Bone Fractures and Alzheimer's Disease and Other Dementias: A Global Burden Analysis with Hospital-Based Contextualization.
    Peidong Zhang, Deng Chen, Jialiu Luo +6
    Risk management and healthcare policyPeer-reviewedCC BY-NCFull textPsychiatry & mental healthEurope PMC
  2. Monitoring multiple rib fractures using pulmonary electrical impedance tomography technology: correlation analysis of pulmonary ventilation changes
    Liming Wang, Lingqing Zhou, Picong You +4
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxymethylene Diphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy
    A. Costa, A. Suits, J. Miller +9
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  4. Diagnostic Concordance Across Text and Image Workflows in Nine Consumer Multimodal Artificial Intelligence Systems for Cutaneous Vascular Anomalies: A Cross-Sectional Audit.
    Guoyong Wang, Hui Bi, Ye Zhang +4
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  5. Assessing diagnostic concordance between rapid on-site evaluation and final histopathology in mediastinal lesions using conventional and endobronchial ultrasound-guided TBNA
    Fatma Hafez, Ashraf Madkour, Wael Emam
    The Egyptian Journal of BronchologyPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{wong2026diagnostic,
  title = {{Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.}},
  author = {Rohin Wong and Andrien Rajakumar and Arkar Lwin and Zina Al-Kaisy and Paul Defty-Wallace and Rashed Al-Khudairi},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.118468},
  url = {https://europepmc.org/article/MED/42921628},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.
AU  - Rohin Wong
AU  - Andrien Rajakumar
AU  - Arkar Lwin
AU  - Zina Al-Kaisy
AU  - Paul Defty-Wallace
AU  - Rashed Al-Khudairi
PY  - 2026
DA  - 2026/10/23
JO  - Cureus
DO  - 10.7759/cureus.118468
UR  - https://europepmc.org/article/MED/42921628
AB  - Scaphoid fractures are the most common carpal bone fracture. Non-union and avascular necrosis are complications of a missed fracture. Therefore, if plain radiographs are normal and symptoms persist, further imaging such as computed tomography (CT) or magnetic resonance imaging (MRI) are often performed. Previous systematic reviews have largely compared their diagnostic accuracy indirectly using separate patient cohorts. Our objective is to determine the diagnostic accuracy of CT for occult scaphoid fractures in patients who underwent both CT and MRI following a negative or equivocal initial radiograph, and to assess concordance between CT and MRI findings. A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. OVID MEDLINE, OVID Embase, and the Cochrane Library were searched for studies published from inception up to August 31, 2026. Eligible studies enrolled adults with clinically suspected scaphoid fracture and a negative or equivocal initial radiograph who subsequently underwent both CT and MRI. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Studies affected by partial verification or incorporation bias were excluded from quantitative synthesis. CT sensitivity and specificity were pooled using a bivariate random-effects model. Concordance between CT and MRI was reported using percentage agreement and Cohen's kappa. Eight studies met the inclusion criteria. Six studies contributed to the primary pooled analysis of CT diagnostic accuracy, with one study reporting two CT readers. Using the first reader data from that study, alongside the five other studies, pooled CT sensitivity was 79% (95% CI 61.5-89.8%) and specificity was 94.4% (95% CI 82.1-98.4%). A sensitivity analysis using the second reader produced a sensitivity of 69.2% (95% CI 48.0-84.6%), with an unchanged specificity of 94.4% (95% CI 85.5-98.0%). Three studies provided CT-MRI concordance data; two demonstrated almost perfect agreement, with Cohen's kappa values of 0.91. The dual-energy CT study demonstrated lower concordance. Three studies used a reference standard independent of both CT and MRI and demonstrated mixed comparative findings. Overall, one study was judged to have low risk of bias, and seven were high risk of bias. In the included studies, CT demonstrated high specificity but more limited sensitivity for occult scaphoid fracture in paired CT-MRI cohorts. These findings align with existing literature reviewing unpaired data sets. Therefore, the findings suggest that CT remains a relevant alternative to MRI, especially in centres where MRI is unavailable or contraindicated, or for surgical planning.
SN  - 2168-8184
ER  -