Rapid Multiparameter Gravitational-Wave Tests of General Relativity with Neural Posterior Estimation
Abstract
Multiparameter gravitational-wave tests of general relativity (GR) are limited by strong correlations among post-Newtonian (PN) phase deformations and the computational cost of Bayesian inference. We present DINGO-TGR, a neural posterior estimation framework that jointly infers binary-source parameters and six PN phase deformations within the TIGER parametrization, using IMRPhenomXPHM waveforms with spin precession and higher-order modes. Importance sampling reweights the neural proposal samples, while principal component analysis (PCA) identifies two well-constrained combinations of PN deformations. We validate the framework using 16 zero-noise GR injections and 12 beyond-GR injections, recovering GR-consistent posteriors in the former and leading-mode shifts consistent with the injected deformations in the latter. For GW150914 and GW250114, our results agree with independent \texttt{bilby-tgr} analyses using \texttt{dynesty}. After training, inference including importance sampling takes approximately 38 minutes and 4.4 hours, respectively, compared with 177 and 238 hours for conventional sampling. GW150914 exhibits a mild offset from GR in the leading PCA mode, whereas GW250114 is consistent with GR. To assess the significance of the GW150914 offset, we analyze 1000 GW150914-like GR injections with independent Gaussian-noise realizations and fixed detector power spectral densities. The resulting empirical upper-tail p-value is 11.5%, indicating that the observed offset does not reject the adopted GR null model at the 5\% significance level. Our results demonstrate the potential of importance-sampling-corrected neural inference for efficient multiparameter GR tests and large-scale injection-based significance assessments.
Related
- Evidence for deviation in gravitational light deflection from general relativity at cosmological scales with KiDS-Legacy and CMB lensing
- Deep Learning Detection of Beyond-General-Relativity Deviations in Gravitational-Wave Signals: A Detection-Threshold Study with Real LIGO Noise
- How general relativity stacks up: Testing gravity by coherently combining gravitational-wave observations
- Biases in Ringdown Tests of General Relativity from Gravitational-Wave Microlensing
- Searching for gravitational wave echo with group equivariant neural posterior estimation
BibTeX
@misc{su2026rapid,
title = {{Rapid Multiparameter Gravitational-Wave Tests of General Relativity with Neural Posterior Estimation}},
author = {Hong Su and Tao Yang and He Wang},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.17038},
eprint = {2611.17038},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.17038},
}
RIS
TY - UNPB
TI - Rapid Multiparameter Gravitational-Wave Tests of General Relativity with Neural Posterior Estimation
AU - Hong Su
AU - Tao Yang
AU - He Wang
PY - 2026
DA - 2026/11/12
PB - arXiv
DO - 10.48550/arxiv.2611.17038
UR - https://arxiv.org/abs/2611.17038
AB - Multiparameter gravitational-wave tests of general relativity (GR) are limited by strong correlations among post-Newtonian (PN) phase deformations and the computational cost of Bayesian inference. We present DINGO-TGR, a neural posterior estimation framework that jointly infers binary-source parameters and six PN phase deformations within the TIGER parametrization, using IMRPhenomXPHM waveforms with spin precession and higher-order modes. Importance sampling reweights the neural proposal samples, while principal component analysis (PCA) identifies two well-constrained combinations of PN deformations. We validate the framework using 16 zero-noise GR injections and 12 beyond-GR injections, recovering GR-consistent posteriors in the former and leading-mode shifts consistent with the injected deformations in the latter. For GW150914 and GW250114, our results agree with independent \texttt{bilby-tgr} analyses using \texttt{dynesty}. After training, inference including importance sampling takes approximately 38 minutes and 4.4 hours, respectively, compared with 177 and 238 hours for conventional sampling. GW150914 exhibits a mild offset from GR in the leading PCA mode, whereas GW250114 is consistent with GR. To assess the significance of the GW150914 offset, we analyze 1000 GW150914-like GR injections with independent Gaussian-noise realizations and fixed detector power spectral densities. The resulting empirical upper-tail p-value is 11.5%, indicating that the observed offset does not reject the adopted GR null model at the 5\% significance level. Our results demonstrate the potential of importance-sampling-corrected neural inference for efficient multiparameter GR tests and large-scale injection-based significance assessments.
ER -